Influence of infrared illumination on the characteristics of CdZnTe detectors

Infrared (IR) radiation of proper wavelength deep penetrating inside the CdZnTe detector may interact with trapping centers and has a significant influence on the trapping-detrapping processes of charge carriers from traps, thereby influencing charge collection efficiency in the detector. We studied the effect of infrared (IR) illumination on the characteristics of planar and quasi-hemispherical CdZnTe detectors. These results show that the near bandgap IR illumination significantly affects the detectors characteristics. By selecting a wavelength and intensity of illumination, detectors spectrometric characteristics can be significantly improved. Improvement of spectrometric characteristics is due to better uniformity of charge collection on the detector volume, as evidenced by the improvement in the total absorption peak symmetry and shape of the output pulses. The degree of improvement is different for various detectors depending on the characteristics of source material used for detector fabrication and theirs dimensions. For example, a detector of sizes 10 x 10 x 5 mm{sup 3} with an initial energy resolution (FWHM) of 20.6 keV at 662 keV under IR illumination was improved up to 9.1 keV, but a detector of sizes 5 x 5 x 2.5 mm{sup 3} with an initial energy resolution (FWHM) of 7.1 keV can be improved up to 4.8 keV. The IR illumination with a properly chosen intensity improves spectrometric characteristic in a wide range of energies without any losses of registration effectiveness. IR Illumination was practically performed using conventional GaAlAs IR LEDs with different peak wavelengths of emitted radiation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of transient change in strain rate on plastic flow behaviour of Al-Mg-Si alloy at elevated temperatures

In extrusion forging processes, the abrupt changes in strain rate follows the plastic deformation of a material within the deforming zone. To simulate accurately this effect, the specific experimental investigation of the plastic flow during the transient change in strain rate should be performed. The present paper deals with the investigation of this effect on the flow stress of an Al-Mg-Si alloy during its deformation at 350 deg. C. The investigation consists of two steps. Both steps are connected to the monotonic uniaxial compression loading of a cylindrical specimen. During the first step the flow behaviour of the alloy is investigated at the constant strain rate wihin the range of 0.1-50 s{sup -1} at the temperature range of 350-430 deg. C. During the second step the strain rate is abruptly increased or decreased from its current value at a fixed engineering strain of 17-21%. From the beginning of the test up to the strain of 17-21% the value of the strain rate is constant and equal to either 1 s{sup -1} or 10 s{sup -1}. At the strain of 17-21% the value of a strain rate is either increased to 10 s{sup -1} or decreased to 1 s{sup -1}.The results of the experimental investigations were used to determine the isothermal flow stress-strain curves of the Al-Mg-Si alloy as well as the heat effect of plastic deformation of the alloy. On basis of these curves, the strain rate sensitivity index m as a function of true strain and temperature was determined. This parameter allows to optimize a technological process of hot forging of the aluminium alloy as well as it is very important data for the construction of a phenomenological flow stress model.

36 MATERIALS SCIENCE↗

Comparison of secondary electron emission simulation to experiment.

Monte Carlo simulation, empirical theories, and close comparison to experiment were used to parameterize the secondary electron emission (SEE) yields of several highly emissive materials for microchannel plates. In addition, a detailed experiment and analysis of gold were carried out at Argonne National Laboratory. The simulation results will be used in the selection of emissive and resistive materials for deposition and characterization experiments that will be conducted by a large-area fast detector project at Argonne.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of candidate secondary electron emission materials.

Secondary electron emission (SEE) yields obtained with empirical models deviate significantly from experiment. Therefore they cannot be used to predict the SEE data for various materials. The angular dependencies of SEE in empirical models are also drastically different and inconvenient for comparison. SEE coefficients were calculated by a theoretical method that uses Monte Carlo simulation, empirical theories, and close comparison to experiment, in order to parameterize the SEE yields of highly emissive materials. We have successfully applied this method to bulk Al{sub 2}O{sub 3}, a highly emissive material for micro-channel plates, as well as to thinly deposited films of Al{sub 2}O{sub 3}. The simulation results will be used in the selection of an emissive material, and if the emission yield of the material is small, as a resistive material for the deposition and characterization experiments that will be conducted by a large-area fast detector project at Argonne National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Gridded Electron Gun for a Sheet Beam Klystron

This paper describes the development of an electron gun for a sheet beam klystron. Initially intended for accelerator applications, the gun can operate at a higher perveance than one with a cylindrically symmetric beam. Results of 2D and 3D simulations are discussed.

43 PARTICLE ACCELERATORS↗

Simulating Dark Current in NLC Structures

Dark current generation and capture are of great importance in high gradient accelerating structure R&D especially for the NLC which aims to operate at 65 MV/m with specific limits on dark current and RF breakdown rates. Although considerable effort has been devoted to building and testing various types of structures to meet these requirements, few theoretical studies have been done to understand these effects in actual structures. This paper focuses on the simulation of dark current in a NLC test structure for which experimental data are available. The parallel time-domain field solver Tau3P and the parallel particle tracking code Track3P are used together to simulate, for the first time, a dark current pulse to compare with the data measured downstream. Results from SLAC X-band 30-cell constant impedance structure for RF drive pulses with different rise times are presented and discussed.

43 PARTICLE ACCELERATORS↗