Engineering Papers⌕ Search

Engineering topics

Ivanchenko, Vladimir

Publications and source records attributed to Ivanchenko, Vladimir.

Validation of Physics Models of Geant4 Versions 10.4.p03, 10.6.p02 and 10.7.p01 using Data from the CMS Experiment

CMS tuned its simulation program and chose a specific physics model of Geant4 by comparing the simulation results with dedicated test beam experiments. Test beam data provide measurements of energy response of the calorimeter as well as resolution for well identified charged hadrons over a large energy region. CMS continues to validate the physics models using the test beam data as well as collision data from the Large Hadron Collider. Isolated charged particles are measured simultaneously in the tracker as well as in the calorimeters. These events are selected using dedicated triggers and are used to measure the response in the calorimeter. Different versions of Geant4 (10.2.p02, 10.4.p03, 10.6.p02) have been used by CMS for its Monte Carlo production and a new version (10.7.p01) is now chosen for future productions. A suitable physics list (collection of physics models) is chosen by optimizing performance against accuracy. A detailed comparison between data and Geant4 predictions is presented in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMS Full Simulation for Run 3

We report the status of the CMS full simulation for Run 3. During the long shutdown of the LHC a significant update has been introduced to the CMS code for simulation. The CMS geometry description is reviewed. Several important modifications were needed. CMS detector description software is migrated to the DD4Hep community developed tool. We will report on our experience obtained during the process of this migration. Geant4 10.7 is the CMS choice for Run 3 simulation productions. We will discuss arguments for this choice, the strategy of adaptation of a new Geant4 version, and will report on the physics performance of the CMS simulation. A special Geant4 Physics List configuration FTFP_BERT_EMM will be described, which provides a compromise between simulation accuracy and CPU performance. A significant fraction of time for simulation of CMS events is spent on tracking of charged particles in a magnetic field. In the CMS simulation a dynamic choice of Geant4 parameters for tracking in field is implemented. A new method is introduced into simulation of electromagnetic components of hadronic showers in the electromagnetic calorimeter of CMS. For low-energy electrons and positrons a parametrization of GFlash type is applied. Results of tests of this method will be discussed. In summary, we expect about 25% speedup of the CMS simulation production for Run 3 compared to the Run 2 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A benchmarking study of Geant4 for Auger electrons emitted by medical radioisotopes

Auger emitting radioisotopes are of great interest in targeted radiotherapy because, once internalised in the tumour cells, they can deliver dose locally to the radiation sensitive targets, while not affecting surrounding cells. Geant4 is a Monte Carlo code widely used to characterise the physics mechanism at the basis of targeted radiotherapy. Here, we benchmarked the modelling of the emission of Auger electrons in Geant4 deriving from the decay of 123 I, 124 I, 125 I radionuclides against existing theoretical approaches. We also compared Geant4 against reference data in the case of 131 Cs, which is of interest for brachytherapy. In the case of 125 I and 131 Cs, the simulation results are compared to experimental measurements as well. Good agreement was found between Geant4 and the reference data. As far as we know, this is the first study aimed to benchmark against experimental measurements the emission of Auger electrons in Geant4 for radiotherapy applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CMS Experience with Adoption of the Community supported DD4hep Toolkit

DD4hep is an open-source software toolkit that provides comprehensive and complete generic detector descriptions for high energy physics (HEP) detectors. The Compact Muon Solenoid collaboration (CMS) has recently evaluated and adopted DD4hep to replace its custom detector description software. CMS has demanding software requirements as a very large, longrunning experiment that must support legacy geometries and study many possible upgraded detector designs of a constantly evolving detector that will be taking data for many years to come. CMS has chosen DD4hep since it is a high-quality, community-supported solution that will benefit from continuing modernization and maintenance. This presentation will discuss the issues of DD4hep adoption, the advantages and disadvantages of the various design choices, performance results, and the integration of the plugin systems from CMS and Gaudi, another open-source software framework. Recommendations about DD4hep based upon the CMS use cases will also be presented.

Vuosalo, Carl↗

Recent progress with the top to bottom approach to vectorization in GeantV

SIMD acceleration can potentially boost by factors the application throughput. Achieving efficient SIMD vectorization for scalar code with complex data flow and branching logic, goes however way beyond breaking some loop dependencies and relying on the compiler. Since the refactoring effort scales with the number of lines of code, it is important to understand what kind of performance gains can be expected in such complex cases. We started to investigate a couple of years ago a top to bottom vectorization approach to particle transport simulation. Percolating vector data to algorithms was mandatory since not all the components can internally vectorize. Vectorizing low-level algorithms is certainly necessary, but not sufficient to achieve relevant SIMD gains. In addition, the overheads for maintaining the concurrent vector data flow and copy data have to be minimized. In the context of a vectorization R&D for simulation we developed a framework to allow different categories of scalar and vectorized components to co-exist, dealing with data flow management and real-time heuristic optimizations. The paper describes our approach on coordinating SIMD vectorization at framework level, making a detailed quantitative analysis of the SIMD gain versus overheads, with a breakdown by components in terms of geometry, physics and magnetic field propagation. We also present the more general context of this R&D work and goals for 2018.

97 MATHEMATICS AND COMPUTING↗

Electromagnetic physics vectorization in the GeantV transport framework

The development of the GeantV Electromagnetic (EM) physics package has evolved following two necessary paths towards code modernization. A first phase required the revision of the main electromagnetic physics models and their implementation. The main objectives were to improve their accuracy, extend them to the new high-energy frontier posed by the Future Circular Collider (FCC) programme and allow a better adaptation to a multi-particle flow. Most of the EM physics models in GeantV have been reviewed from theoretical perspective and rewritten with vector-friendly implementations, being now available in scalar mode in the alpha release. The second phase consists of a thorough investigation on the possibility to vectorise the most CPU-intensive physics code parts, such as final state sampling. We have shown the feasibility of implementing electromagnetic physics models that take advantage of SIMD/SIMT architectures, thus obtaining gains in performance. After this phase, the time has come for the GeantV project to take a step forward towards the final proof of concept. This takes shape through the testing of the full simulation chain (transport + physics + geometry) running in vectorized mode. In this paper we will present the first benchmark results obtained after vectorizing a full set of electromagnetic physics models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress of Geant4 electromagnetic physics developments and applications

We report on developments of the Geant4 electromagnetic physics sub-libraries of Geant4 release 10.4 and beyond. Modifications are introduced to the models of photoelectric effect, bremsstrahlung, gamma conversion, single and multiple scattering. The theory-based Goudsmit-Saunderson model of electron/positron multiple scattering has been recently reviewed and a new improved version, providing the most accurate results for scattering of electrons and positrons, was made available. The updated interfaces, models and configurations have already been integrated into LHC applications and may be useful for any type of simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Geant4 fragmentation for Heavy Ion Therapy

12 C ion therapy has had growing interest in recent years for its excellent dose conformity. However at therapeutic energies, which can be as high as 400 MeV/u, carbon ions produce secondary fragments. For an incident 400 MeV/u 12 C ion beam, ~70% of the beam will undergo fragmentation before the Bragg Peak. The dosimetric and radiobiological impact of these fragments must be accurately characterised, as it can result in increasing the risk of secondary cancer for the patient as well as altering the relative biological effectiveness. Here, this work investigates the accuracy of three different nuclear fragmentation models available in the Monte Carlo Toolkit Geant4, the Binary Intranuclear Cascade (BIC), the Quantum Molecular Dynamics (QMD) and the Liege Intranuclear Cascade (INCL++). The models were benchmarked against experimental data for a pristine 400 MeV/u 12 C beam incident upon a water phantom, including fragment yield, angular and energy distribution. For fragment yields the three alternative models agreed between ~5 and ~35% with experimental measurements, the QMD using the “Frag” option gave the best agreement for lighter fragments but had reduced agreement for larger fragments. For angular distributions INCL++ was seen to provide the best agreement among the models for all elements with the exception of Hydrogen, while BIC and QMD was seen to produce broader distributions compared to experiment. BIC and QMD performed similar to one another for kinetic energy distributions while INCL++ suffered from producing lower energy distributions compared to the other models and experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in Hadronic Physics Modelling in Geant4

Geant4 offers a set of models to simulate hadronic showers in calorimeters. Recent improvements to several models relevant to the modelling of hadronic showers are discussed. These include improved cross sections, a revision of the FTF model, the addition of quasi-elastic scattering to the QGS model, and enhancements in the nuclear precompound and de-excitation models. The validation of physics models against thin target experiments has been extended especially in the energy region 10 GeV and below. Examples of new validation results are shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗