Engineering Papers⌕ Search

Engineering topics

Ivanchenko, Vladimir

Publications and source records attributed to Ivanchenko, Vladimir.

Validation of Physics Models of Geant4 Versions 10.4.p03, 10.6.p02 and 10.7.p01 using Data from the CMS Experiment

CMS tuned its simulation program and chose a specific physics model of Geant4 by comparing the simulation results with dedicated test beam experiments. Test beam data provide measurements of energy response of the calorimeter as well as resolution for well identified charged hadrons over a large energy region. CMS continues to validate the physics models using the test beam data as well as collision data from the Large Hadron Collider. Isolated charged particles are measured simultaneously in the tracker as well as in the calorimeters. These events are selected using dedicated triggers and are used to measure the response in the calorimeter. Different versions of Geant4 (10.2.p02, 10.4.p03, 10.6.p02) have been used by CMS for its Monte Carlo production and a new version (10.7.p01) is now chosen for future productions. A suitable physics list (collection of physics models) is chosen by optimizing performance against accuracy. A detailed comparison between data and Geant4 predictions is presented in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMS Full Simulation for Run 3

We report the status of the CMS full simulation for Run 3. During the long shutdown of the LHC a significant update has been introduced to the CMS code for simulation. The CMS geometry description is reviewed. Several important modifications were needed. CMS detector description software is migrated to the DD4Hep community developed tool. We will report on our experience obtained during the process of this migration. Geant4 10.7 is the CMS choice for Run 3 simulation productions. We will discuss arguments for this choice, the strategy of adaptation of a new Geant4 version, and will report on the physics performance of the CMS simulation. A special Geant4 Physics List configuration FTFP_BERT_EMM will be described, which provides a compromise between simulation accuracy and CPU performance. A significant fraction of time for simulation of CMS events is spent on tracking of charged particles in a magnetic field. In the CMS simulation a dynamic choice of Geant4 parameters for tracking in field is implemented. A new method is introduced into simulation of electromagnetic components of hadronic showers in the electromagnetic calorimeter of CMS. For low-energy electrons and positrons a parametrization of GFlash type is applied. Results of tests of this method will be discussed. In summary, we expect about 25% speedup of the CMS simulation production for Run 3 compared to the Run 2 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A benchmarking study of Geant4 for Auger electrons emitted by medical radioisotopes

Auger emitting radioisotopes are of great interest in targeted radiotherapy because, once internalised in the tumour cells, they can deliver dose locally to the radiation sensitive targets, while not affecting surrounding cells. Geant4 is a Monte Carlo code widely used to characterise the physics mechanism at the basis of targeted radiotherapy. Here, we benchmarked the modelling of the emission of Auger electrons in Geant4 deriving from the decay of 123 I, 124 I, 125 I radionuclides against existing theoretical approaches. We also compared Geant4 against reference data in the case of 131 Cs, which is of interest for brachytherapy. In the case of 125 I and 131 Cs, the simulation results are compared to experimental measurements as well. Good agreement was found between Geant4 and the reference data. As far as we know, this is the first study aimed to benchmark against experimental measurements the emission of Auger electrons in Geant4 for radiotherapy applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗