Preparations for Operational JOSFRA Retrievals and Preliminary Science Goals
No abstract provided
Engineering topics
Publications and source records attributed to Irion, Bill.
No abstract provided
The CubeSat Infrared Atmospheric Sounder (CIRAS) will measure upwelling infrared radiation of the Earth in the MWIR region of the spectrum from space on a CubeSat. CIRAS will demonstrate two new infrared sounding technologies. The first is a 2D array of High Operating Temperature Barrier Infrared Detector (HOT-BIRD) material, selected for its high uniformity, low cost, low noise and higher operating temperatures than traditional materials. The detectors are hybridized to a commercial ROIC and commercial camera electronics. The second technology is an MWIR Grating Spectrometer (MGS) to be designed and developed by Ball Aerospace to provide imaging spectroscopy for atmospheric sounding in a CubeSat volume. The MGS has no moving parts and is based on heritage spectrometers including the Ball Aerospace Spaceborne Infrared Atmospheric Sounder for GEO (SIRAS-G) IIP of 2007. JPL will develop the mechanical, electronic and thermal subsystems for CIRAS. The spacecraft will be a commercially available CubeSat. The integrated system will be a complete 6U CubeSat capable of measuring temperature and water vapor profiles with good lower tropospheric sensitivity. The CIRAS is the first step towards the development of an Earth Observing Nanosatellite Infrared (EON-IR) for potential use in a future operational forecasting system.
No abstract available
This talk is about accomplishments with AIRS data and what we have learned from almost three years of data what part of this is emerging in Version 4.0 what part we would like to see filtering into Version 5.0 and what part constitute limitations in the AIRS requirements, such as spectral and spatial resolution, which have to be deferred to the wish list for the next generation hyperspectral sounder. The AIRS calibration accuracy at the 1OOmK and stability at the 6 mK/year level are amazing. It establishes the unique capability of a cooled grating array spectrometer in Earth orbit for climate research. Data which are sufficiently clear to match the radiometric accuracy of the instrument, have a yield of less than 1%. This is OK for calibration. The 2616/cm window channel combined with the RTG.SST for tropical ocean allow excellent assessment radiometric calibration accuracy and stability. For absolute calibration verification 100mK is the limit due to cloud contamination. The 10 micron window channels can be used for stability assessment, but accuracy is limited at 300mK due to water continuum absorption uncertainties.
Explore the source record for details and available documents.