A new method for the production of large spherical monosized polymer particles for biomedical and chromatographic applications
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Hyson, M. T..
Explore the source record for details and available documents.
An account is given of the charged drop levitation characteristics of two different devices: (1) a feedback-controlled electrostatic levitator able to lift a several mm-diameter drop in 1g conditions, which is applicable to drop dynamics, crystal growth, and supercooling/solidification experiments; and (2) a linear quadrupole levitator, whose advantages are demonstrated in light of the results obtained for the charged drop instability experiment. The cause of the premature drop burstings observed is suggested to be an electron avalanche in the surrounding gaseous medium rather than the Rayleigh limit.
A containerless method that produces highly uniform microspheres (greater than 50 microns in diameter) from many materials has been developed for biomedical applications. A piezoelectrically vibrated drop generator forms uniform (monodisperse) monomer droplets that are either electrostatistically levitated and polymerized using UV irradiation, or free-radical polymerized. Spheres of 2-hydroxyethyl methacrylate polymer have been produced with diameters of 155 microns + or - 1.57 percent.
This paper describes an electrostatic positioning instrument which was developed at the Jet Propulsion Laboratory to enable experimenters to conduct containerless material science experiments in space. Samples that are to be studied are electrically charged and controlled by the electrostatic force produced by a set of properly arranged electrodes. Three different types of positioners are described, i.e., the dish type, the ring type, and the tetrahedral type. In all these systems, the positioning and the damping of the sample is accomplished by a feedback control system. The advantage of this electrostatic positioning method, in comparison to the other methods, such as acoustic and electromagnetic, lies in the fact that it can operate in a high vacuum and does not require the material to be electrically conductive as long as the material can carry a certain amount of charge.
The potential hazard imposed by the reflection of the Sun's image by the solar power satellite (SPS) was examined. In the worst case, where the transmitter is assumed to be a perfect mirror reflecting the Sun's image normal to the atmosphere, the total energy received by the eye would be 3.36 x 10 to the -7th power watts. The eye's optics would blur the 5.6 sec of art image of the transmitter over a disk approximately 6 minutes arc in diameter, reducing the maximum intensity at the retina by 99%. A given cone in the retina would receive even less energy due to the constant random microtremors and microsaccadic movements of the eye muscles which move the retina over an area some 8 minutes of arc in radius, even during steady fixation. Therefore, very conservative estimates show that the reflections from the transmitter could be viewed safety for at least 3.2 hours and that the entire SPS structure could be viewed for a minimum of 1 hour. The solares mirror is briefly considered and is shown to be safe to view for at least 2.4 minutes.