Engineering Papers⌕ Search

Engineering topics

Hunt, L. R.

Publications and source records attributed to Hunt, L. R..

51 records · Page 3

Global mappings of nonlinear systems

A theorem and its corollary are presented in which conditions are stated for a global transformation of a nonlinear system to a linear system. An explicit method for constructing such a transformation is given, and the important noncharacteristic matrix is introduced. Examples illustrating the technique are presented.

Hunt, L. R.↗

Observability for two dimensional systems

Sufficient conditions that a two-dimensional system with output is locally observable are presented. Known results depend on time derivatives of the output and the inverse function theorem. In some cases, no informaton is provided by these theories, and one must study observability by other methods. The observability problem is dualized to the controllability problem, and the deep results of Hermes on local controllability are applied to prove a theorem concerning local observability.

Hunt, L. R.↗

Control of nonlinear time-varying systems

Necessary and sufficient conditions are given for a time-varying nonlinear system of specific form to be transformed into a time-invariant controllable linear system. Since the present work will be in a neighborhood of the origin, it is unnecessary to name specific sets and it is assumed that all assumptions, conditions and results hold in an open set in the appropriate Euclidean space that contains the origin. This theory can be combined with the global inverse function theorems to produce global results.

Hunt, L. R.↗

Aerothermal environment in chordwise gaps between split elevons at Mach 6.8

A large scale model representing a wing elevon junction on a shuttle-type entry vehicle was aerothermally tested in the Langley 8 foot high temperature structures tunnel with a turbulent boundary layer on the wing and elevon. The flow pattern between elevons was studied, and the pressure and heat load were determined within the chordwise gaps formed by adjacent elevons and by the stub fairing which separates the elevons. Model angle, elevon deflection angle, and gap widths were varied. Heating in the gaps was generally proportional to windward surface heating and inversely proportional to gap width. Maximum heating between the elevon and stub was 36 percent of the windward wing surface for a 0.18 cm wide elevon stub gas, and maximum heating between elevons was 30 percent of the heating on the windward elevon surfaces for a 7.7 cm wide elevon gap.

Hunt, L. R.↗

Cyclic tests of P-bulb end-seal designs for a shuttle-type wing-elevon cove membrane seal

Four P-bulb end seal designs were tested at room temperature in a cyclic seal test apparatus. Test results show that all the P-bulb end seals have the durability required for a 100 mission life (neglecting possible elevated-temperature effects) and three of the four P-bulbs provide an adequate seal against a 7.0-kPa air pressure differential. Antifriction material attached to the P-bulb rub surface reduced friction slightly but could degrade the sealing effectiveness. A flat rub surface molded into the P-bulb discouraged wrinkling and rolling and thereby reduced leakage. However, the P-bulbs lacked resilience, as indicated by increased leakage when P-bulb compression was reduced. The best P-bulb design tested included an antifriction interface bonded to a flat surface molded into the P-bulb.

Hunt, L. R.↗

Aerodynamic heating in large cavities in an array of RSI tiles

A large panel of reusable surface insulation (RSI) tiles including lost tile cavities was aerothermally tested in the Langley 8 foot high temperature structures tunnel to determine both the heat load within the cavities and the structural performance of the RSI surrounding the cavities. Tests were conducted with a turbulent boundary layer at a nominal free stream Mach number of 6.6, a total temperature of 1800 K, a Reynolds number per meter of 5 million, and a dynamic pressure of 62 kPa. The maximum aerodynamic heating to the floor of the cavity was two to three times the normal surface heating. The cavity heating rates agreed with data from other facilities and were successfully correlated with an empirical equation. A zippering failure occurred to a tile downstream of a double tile cavity when the separated flow attached to the floor of the cavity and forced the tile from its position.

Hunt, L. R.↗

Performance of a mullite reusable surface insulation system in a hypersonic stream

The thermal and structural performance of a large panel of mullite reusable surface insulation (RSI) tiles was determined by a series of aerothermal tests in the Langley 8-foot high-temperature structures tunnel. The test panel was designed to represent a portion of the surface structure on a space shuttle orbiter fuselage along a 1,150 K isotherm with the mullite tile system bonded directly to the primary structure. Aerothermal tests were conducted at a free-stream Mach number of 6.7, a total temperature of 1,880 K, a unit Reynolds number of 4.6 million per meter, and dynamic pressure of 62 kPa. The thermal response of the mullite tile was as predicted, and the bond-line temperature did not exceed the design level of 570 K during a typical entry-heat cycle. Geometric irregularities of the tile gaps affected the tile edge temperatures when exposed to hypersonic flow. The tile coating demonstrated good toughness to particle impacts, but the coating cracked and flaked with thermal cycles. The gap filler of woven silica fibers appeared to hinder flow penetration into the gaps and withstood the flow shear of the present tests.

Hunt, L. R.↗

Performance of LI-1542 reusable surface insulation system in a hypersonic stream

The thermal and structural performance LI-1542 reusable surface insulation (RSI) tiles was investigated. The test panel was designed to represent part of the surface structure on a space shuttle orbiter fuselage along a 1250 K isotherm. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1820 K, Reynolds numbers of 2 millon and 5 million per meter, and dynamic pressures of 26 and 65 kPa. The RSI tiles demonstrated good thermal protection and structural integrity. High temperatures were caused by misalinement in tile height, offset the tile longitudinal alinement, and leakage around thermal seals when differential pressure existed across the panel. The damage tolerance of LI-1542 RSI appeared high. The tile coating crazed early in the test program, but this did not effect the tile integrity. Erosion of the tile edges occurred at forward-facing steps and at the ends of longitudinal gaps because of particle impacts and flow shear.

Hunt, L. R.↗

Performance of full size metallic and RSI thermal protection systems in a Mach 7 environment

The integrity and reusability of three flight-weight metallic and RSI thermal protection systems, designed for the Shuttle entry environment, have been demonstrated. Each model successfully survived over 23 entry thermal cycles without serious degradation. The metallic systems were more tolerant of the hostile environment and provided a higher degree of reusability than did the RSI. Thermal expansion slip joints of the metallic TPS successfully prevented hot gas ingress to the substructure. The RSI demonstrated high damage tolerance and field repairs increased its reusability. Heat-transfer tests to further assess RSI gap heating indicate that stacked tile orientations may impose a penalty on tile thickness. Parameters influencing RSI impingement heating were determined, and the heating data were correlated.

Bohon, H. L.↗

Performance of LI-1542 reusable surface insulation system in a hypersonic stream

The thermal and structural performance of a large panel of LI-1542 reusable surface insulation tiles was determined by a series of cyclic heating tests using radiant lamps and aerothemal tests in the Langley 8-foot high-temperature structures tunnel. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1830 K, Reynolds numbers of 2.0 and 4,900,000 per meter, and dynamic pressures of 29 and 65 kPa. The results suggest that pressure gradients in gaps and flow impingement on the header walls at the end of longitudinal gaps are sources for increased gap heating. Temperatures higher than surface radiation equilibrium temperature were measured deep in gaps and at the header walls. Also, the damage tolerance of the LI-1542 tiles appears to be very high. Tile edge erosion rate was slow; could not be tolerated in a shuttle application. Tiles soaked with water and subjected to rapid depressurization and aerodynamic heating showed no visible evidence of damage.

Hunt, L. R.↗

Loading and heating of a large flat plate at Mach 7 in the Langley 8-foot high-temperature structures tunnel

Surface pressure and cold-wall heating rate distributions (wall-temperature to total-temperature ratio approximately 0.2) were obtained on a large, flat calibration panel at a nominal Mach number of 7 in an 8-foot high-temperature structures tunnel. Panel dimensions were 42.5 by 60.0 in. Test objectives were: (1) to map available flat-plate loading and heating provided by the facility and (2) to determine effectiveness of leading-edge bluntness, boundary-layer trips, and aerodynamic fences in generating a uniform, streamwise turbulent flow field over the test surface of a flat-sided panel holder.

Deveikis, W. D.↗