Engineering Papers⌕ Search

Engineering topics

Humphreys, Dave A.

Publications and source records attributed to Humphreys, Dave A..

Development and experimental qualification of novel disruption prevention techniques on DIII-D

Novel disruption prevention solutions spanning a range of control regimes are being developed and tested on DIII-D to enable ITER success. First, a new real-time control algorithm has been developed and tested for regulating nearness to stability limits and maintaining safety-margins. Its first application has been for reliable prevention of vertical displacement events (VDEs) by adjusting plasma elongation (κ) and the inner-gap between the plasma and inner-wall in response to real- time open-loop VDE growth rate (γ) estimators. VDEs were robustly prevented up to average open-loop growth rates of 800 rad/s with initial tunings, with only applying shape modification when near safety limits. Second, the disruption risk during fast, emergency shutdown after large tearing and locked modes can be significantly improved by transitioning to a limited topology during shutdown. More than 50% of emergency limited shutdowns after locked modes reach a final normalized current I_N < 0.3 before terminating, scaling to the 3 MA ITER requirement. Furthermore, this is in contrast to diverted shutdowns, the majority of which disrupt at I_N > 0.8. Despite improvements, these results highlight the critical importance of early prevention. Third, a novel emergency shut down method has been developed which excites instabilities to form a warm, helical core post-thermal quench. The current quench extends to ~100ms and avoids VDEs and runaway electron generation. Novel real-time machine learning disruption prediction has been integrated with the DIII-D proximity controller, and a real- time compatible multi-mode MHD spectroscopy technique has been developed. Results presented here were enabled by a focused effort, the Disruption Free Protocol, in DIII-D’s 2019-20 campaign to complement disruption prevention experiments with a large piggy-back program. In addition to testing novel techniques, it is estimated to have helped avoid 32 potential disruptions in piggyback operations with rapid, early shutdowns after large rotating n=1 or locked modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-based real-time surface heat flux and temperature estimation for the DIII-D tokamak

A control-oriented model for monitoring of wall power flux densities on the DIII-D tokamak has been successfully implemented and validated experimentally. Future reactors will have to withstand severe steady state high heat flux loads on plasma-facing components (PFCs). Due to the difficulty of directly-measuring local heat fluxes on these components, monitoring and protection of PFCs during the plasma discharge can benefit from simplified physics-based real-time (RT) functional models to estimate and guide heat load control. As a first step into the development, a control-oriented model for monitoring of wall power flux densities and temperatures on DIII-D tokamak has been successfully implemented. The paper discusses the experimental demonstration and comparison of the 2-D model-based wall heat flux algorithm on the DIII-Dinner wall limiter (IWL) against infra-red camera heat flux measurements for limited plasma configurations. The paper also reports on the benchmarking of the field line tracing environment, SMITER, developed at ITER organization on DIII-D tokamak against experimental IR diagnostic data and the derivation of the component shaping weighting factors for the 2-D model-based approach. Here, the extension of the model-based approach for surface temperature estimation on the DIII-D IWL is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in disruption prevention for ITER

Key plasma physics and real-time control elements needed for robustly stable operation of high fusion power discharges in ITER have been shown in recent research worldwide. Recent analysis has identified the current density profile as the main drive for disruptive instabilities in discharges simulating ITER's baseline scenario with high and low external torque. Ongoing development of model-based profile control and active control of magnetohydrodynamic instabilities is improving the stability of multiple scenarios. Significant advances have been made toward real-time physics-based prediction of instabilities, including path-oriented analysis, active sensing, and machine learning techniques for prediction that are beginning to go beyond simple disruption mitigation trigger applications. Active intervention adds to prevention of disruptions, including forced rotation of magnetic islands to prevent wall locking, and localized heating/current drive to shrink the islands. Stable discharge rampdowns have been achieved with the fastest ITER-like scaled current ramp rates, while maintaining an X-point configuration. Moreover, these elements are being integrated into stable operating scenarios and new event-handling systems for off-normal events in order to develop the physics basis and techniques for robust control in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-machine analysis of termination scenarios with comparison to simulations of controlled shutdown of ITER discharges

To improve our understanding of the dynamics and control of ITER terminations, a study has been carried out on data from existing tokamaks. The aim of this joint analysis is to compare the assumptions for ITER terminations with the present experience basis. The study examined the parameter ranges in which present day devices operated during their terminations, as well as the dynamics of these parameters. The analysis of a database, built using a selected set of experimental termination cases, showed that, the H-mode density decays slower than the plasma current ramp-down. The consequential increase in f<sub>GW</sub> limits the duration of the H-mode phase or result in disruptions. The lower temperatures after the drop out of H-mode will allow the plasma internal inductance to increase. But vertical stability control remains manageable in ITER at high internal inductance when accompanied by a strong elongation reduction. This will result in ITER terminations remaining longer at low q (q<sub>95</sub>~3) than most present-day devices during the current ramp-down. A fast power ramp-down leads to a larger change in β<sub>p</sub> at the H-L transition, but the experimental data showed that these are manageable for the ITER radial position control. The analysis of JET data shows that radiation and impurity levels significantly alter the H-L transition dynamics. Self-consistent calculations of the impurity content and resulting radiation should be taken into account when modelling ITER termination scenarios. Here, the results from this analysis can be used to better prescribe the inputs for the detailed modelling and preparation of ITER termination scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗