Engineering Papers⌕ Search

Engineering topics

Hui, Yan

Publications and source records attributed to Hui, Yan.

A meta-analysis of 1,119 manipulative experiments on terrestrial carbon-cycling responses to global change

Direct quantification of terrestrial biosphere responses to global change is crucial for projections of future climate change in Earth system models. Here, we synthesized ecosystem carbon-cycling data from 1,119 experiments performed over the past four decades concerning changes in temperature, precipitation, CO2 and nitrogen across major terrestrial vegetation types of the world. Most experiments manipulated single rather than multiple global change drivers in temperate ecosystems of the USA, Europe and China. The magnitudes of warming and elevated CO2 treatments were consistent with the ranges of future projections, whereas those of precipitation changes and nitrogen inputs often exceeded the projected ranges. Increases in global change drivers consistently accelerated, but decreased precipitation slowed down carbon-cycle processes. Nonlinear (including synergistic and antagonistic) effects among global change drivers were rare. Belowground carbon allocation responded negatively to increased precipitation and nitrogen addition and positively to decreased precipitation and elevated CO2. The sensitivities of carbon variables to multiple global change drivers depended on the background climate and ecosystem condition, suggesting that Earth system models should be evaluated using site-specific conditions for best uses of this large dataset. Together, this synthesis underscores an urgent need to explore the interactions among multiple global change drivers in underrepresented regions such as semi-arid ecosystems, forests in the tropics and subtropics, and Arctic tundra when forecasting future terrestrial carbon-climate feedback.

Song, Jian↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

Development and Clinical Evaluation of a Three-Dimensional Cone-Beam Computed Tomography Estimation Method Using a Deformation Field Map

Purpose: To develop a three-dimensional (3D) cone-beam computed tomography (CBCT) estimation method using a deformation field map, and to evaluate and optimize the efficiency and accuracy of the method for use in the clinical setting. Methods and Materials: We propose a method to estimate patient CBCT images using prior information and a deformation model. Patients' previous CBCT data are used as the prior information, and the new CBCT volume to be estimated is considered as a deformation of the prior image volume. The deformation field map is solved by minimizing deformation energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. This method was implemented in 3D form using hardware acceleration and multi-resolution scheme, and it was evaluated for different scan angles, projection numbers, and scan directions using liver, lung, and prostate cancer patient data. The accuracy of the estimation was evaluated by comparing the organ volume difference and the similarity between estimated CBCT and the CBCT reconstructed from fully sampled projections. Results: Results showed that scan direction and number of projections do not have significant effects on the CBCT estimation accuracy. The total scan angle is the dominant factor affecting the accuracy of the CBCT estimation algorithm. Larger scan angles yield better estimation accuracy than smaller scan angles. Lung cancer patient data showed that the estimation error of the 3D lung tumor volume was reduced from 13.3% to 4.3% when the scan angle was increased from 60 Degree-Sign to 360 Degree-Sign using 57 projections. Conclusions: The proposed estimation method is applicable for 3D DTS, 3D CBCT, four-dimensional CBCT, and four-dimensional DTS image estimation. This method has the potential for significantly reducing the imaging dose and improving the image quality by removing the organ distortion artifacts and streak artifacts shown in images reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting non-Abelian geometric phases with three-level {Lambda} systems

We show that a non-Abelian gauge potential in two nearly degenerated dressed states may be induced by two laser beams interacting with a three-level {Lambda} atomic system. We demonstrate that the populations of the atomic states at the end of a composed path formed by two closed loops are dependent on the order of those two loops, showing an unambiguous signature of the non-Abelian geometric phase. Through numerical calculations, we show that the non-Abelian feature of the geometric phases can be tested under realistic conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The investigation of depoling mechanism of densified KNbO{sub 3} piezoelectric ceramic

Thermal depoling phenomena determine the upper temperature limit of the piezoelectric ceramics in application. In this paper, high-densified KNbO{sub 3} ceramics derived from single-crystalline nanostructures exhibited favorable piezoelectric constants d{sub 33}, which varied from 105 to 80 pC/N over a broad temperature range from 25 to 225 deg. C. In situ x-ray diffraction combined with Raman spectra demonstrate clearly the transition sequence of crystallographic orientations during thermal depoling process. The interaction between defect dipoles D and spontaneous polarization inside domains P{sub s} favored to preserve piezoelectric activity, while the spontaneous rotation of P{sub s} induced by the phase transition resulted in the deliquesce of d{sub 33}.

36 MATERIALS SCIENCE↗

Shaping Biphoton Temporal Waveforms with Modulated Classical Fields

We experimentally demonstrate a technique for shaping the temporal quantum waveform of narrow-band biphotons generated in a cold atomic ensemble via four-wave mixing by periodically modulating the two input classical lasers. We show that it is possible to generate nonclassical paired photons with a predesigned shape of the correlation function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependence of depolarization temperature on cation vacancies and lattice distortion for lead-free 74(Bi{sub 1/2}Na{sub 1/2})TiO{sub 3}-20.8(Bi{sub 1/2}K{sub 1/2})TiO{sub 3}-5.2BaTiO{sub 3} ferroelectric ceramics

In this paper, the off-morphotropic-phase-boundary 74(Bi{sub 1/2}Na{sub 1/2})TiO{sub 3}-20.8(Bi{sub 1/2}K{sub 1/2})TiO{sub 3}-5.2BaTiO{sub 3} ceramics were fabricated at different sintering temperatures. It was found out that as the sintering temperature increases, the volatilization of the A-site elements is aggravated, thus generating the oxygen vacancies; meanwhile, the tetragonality of the perovskite lattice reduces gradually. Besides, the temperature-dependent dielectric responses revealed that as the sintering temperature increases, the depolarization temperature T{sub d} decreases while the Curie-Weiss point T{sub C} increases. It is suggested that the lattice distortion, other than the oxygen vacancies, is the crucial factor in influencing the depolarization temperature.

36 MATERIALS SCIENCE↗

Clinical Evaluation of Positioning Verification Using Digital Tomosynthesis and Bony Anatomy and Soft Tissues for Prostate Image-Guided Radiotherapy

Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). Methods and Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used: digitally reconstructed radiographs vs. on-board orthogonal paired radiographs for the 2D method, coronal-reference DTS vs. on-board coronal DTS for the coronal-DTS method, sagittal-reference DTS vs. on-board sagittal DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. The registration results were compared. Results: The systematic errors in all methods were <1 mm/1{sup o}. When registering the bony anatomy, the mean vector difference was 0.21 {+-} 0.11 cm between 2D and CBCT, 0.11 {+-} 0.08 cm between CBCT and coronal DTS, and 0.14 {+-} 0.07 cm between CBCT and sagittal DTS. The correlation between CBCT to DTS was stronger (coefficient = 0.92-0.95) than the correlation between 2D and CBCT or DTS (coefficient = 0.81-0.83). When registering the soft tissue, the mean vector difference was 0.18 {+-} 0.11 cm between CBCT and coronal DTS and 0.29 {+-} 0.17 cm between CBCT and sagittal DTS. The correlation coefficient of CBCT to sagittal DTS and to coronal DTS was 0.84 and 0.92, respectively. Conclusion: DTS could provide equivalent results to CBCT when the bony anatomy is used as landmarks for prostate image-guided radiotherapy. For soft tissue-based positioning verification, coronal DTS produced equivalent results to CBCT, but sagittal DTS alone was insufficient. DTS could allow for comparable soft tissue-based target localization with faster scanning time and a lower imaging dose compared with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator

A new Novalis Tx system equipped with a high definition multileaf collimator (HDMLC) recently became available to perform both image-guided radiosurgery and conventional radiotherapy. It is capable of delivering a highly conformal radiation dose with three energy modes: 6 MV photon energy, 15 MV photon energy, and 6 MV photon energy in a stereotactic radiosurgery mode with 1000 MU/min dose rate. Dosimetric characteristics of the new Novalis Tx treatment unit with the HDMLC are systematically measured for commissioning. A high resolution diode detector and miniion-chamber detector are used to measure dosimetric data for a range of field sizes from 4x4 mm to 400x400 mm. The commissioned Novalis Tx system has passed the RPC stereotactic radiosurgery head phantom irradiation test. The Novalis Tx system not only expands its capabilities with three energy modes, but also achieves better beam conformity and sharer beam penumbra with HDMLC. Since there is little beam data information available for the new Novalis Tx system, we present in this work the dosimetric data of the new modality for reference and comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗