Engineering Papers⌕ Search

Engineering topics

Hubbard, Joshua Allen

Publications and source records attributed to Hubbard, Joshua Allen.

At least 19 records

Density functional theory (DFT) study of UF 6 hydrolysis: reaction pathways, spectroscopy, and chemical kinetics

Depleted uranium hexafluoride (UF 6 ), a stockpiled byproduct of the nuclear fuel cycle, reacts readily with atmospheric humidity, but the gas-phase reaction mechanism and associated chemical kinetics are poorly understood. During the performance period we undertook development of a state-of-the-art ab initio gas-phase chemical kinetics simulation workflow to model the hydrolysis of uranium hexafluroride (UF 6 ). In doing so, we addressed several outstanding issues in the theoretical treatment of uranium-containing systems. At the outset it was unclear how to generate accurate estimates of kinetic and thermodynamic data for U-containing chemical reactions. Generation of such data has been made routine. Prior to our work, the literature associated with UF 6 hydrolysis were disparate and inaccurate. This body of work provides a modern and comprehensive theoretical assessment of the reaction mechanism, molecular clustering towards deposition, and chemical kinetics. New methodological implementations and software integrations resulting from this work are also highlighted. As much as possible, our predictions were validated against experimental data including particle morphologies, vibrational spectroscopy, atomization enthalpies, and kinetic rate constants. Nevertheless, we were unable to reconcile kinetic measurements with high-accuracy simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ Characterization of Soot Aggregates Produced by Burning Contaminated Liquid Fuels with Nuclear Waste Surrogate

The motivation of this work was to complement other studies intended to enhance and update DOE-HDBK-3010-94 for hazard scenarios like nuclear waste fires. In this work, a uniquely designed combustion chamber was successfully integrated with a light scattering technique to characterize soot aggregates. The chamber design allowed for soot investigation within the flame as well as after soot left the incandescent flame region.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Multi-physics Computational Investigation of Droplet Pathogen Transport Eminating from Synthetic Coughs and Breathing

In response to the global SARS-CoV-2 transmission pandemic, Sandia National Laboratories Rapid Lab-Directed Research and Development (LDRD) COVID-19 initiative has deployed a multi-physics, droplet-laden, turbulent low-Mach simulation tool to model pathogen-containing water droplets that emanate from synthetic human coughing and breathing. The low-Mach turbulent Eulerian/point-particle Lagrangian methodology directly couples mass, momentum, energy, and species to capture droplet evaporation physics that supports the ability to distinguish between droplets that deposit and those that persist in the environment. Additionally, the cough mechanism is modeled as a pulsed-spray with a prescribed log-normal droplet size distribution. Simulations demonstrate direct droplet deposition lengths in excess of three meters while the persistence of a droplet nuclei entrained within a buoyant plume is noted. Including the effect of protective barriers demonstrates effective mitigation of large-droplet transport. For coughs into a protective barrier, jet impingement and large-scale re-circulation can drive droplets vertically and back towards the subject while supporting persistence of droplet nuclei. Simulations in quiescent conditions demonstrate droplet preferential concentrations due to the coupling between vortex ring shedding and the subsequent advection of a series of three-dimensional rings that tilt and rise vertically due to a misalignment between the initial principle vortex trajectory and gravity. These resolved coughing simulations note vortex ring formation, roll-up and breakdown, while entraining droplet nuclei for large distances and time scales.

42 ENGINEERING↗

High Air-Flow Aerosol Filtration Testing

Pressure losses and aerosol collection efficiencies were measured for fibrous filter materials at air-flow rates consistent with high efficiency filtration (hundreds of cubic feet per minute). Microfiber filters coated with nanofibers were purchased and fabricated into test assemblies for a 12-inch duct system designed to mimic high efficiency filtration testing of commercial and industrial processes. Standards and specifications for high efficiency filtration were studied from a variety of institutions to assess protocols for design, testing, operations and maintenance, and quality assurance (e.g., DOE, ASHRAE, ASME). Three materials with varying Minimum Efficiency Reporting Values (MERV) were challenged with sodium chloride aerosol. Substantial filter loading was observed where aerosol collection efficiencies and pressure losses increased during experiments. Filter designs will be optimized and characterized in subsequent years of this study. Additional testing will be performed with higher hazard aerosols at Oak Ridge National Laboratory.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-compartment Aerosol Transport Model

A simple aerosol transport model was developed for a multi-compartmented cleanroom. Each compartment was treated as a well-mixed volume with ventilating supply and return air. Gravitational settling, intercompartment transport, and leakage of exterior air into the system were included in the model. A set of first order, coupled, ordinary differential equations was derived from the conservation equations of aerosol mass and air mass. The system of ODEs was then solved in MATLAB using pre-existing numerical methods. The model was verified against cases of (1) constant inlet-duct concentration, and (2) exponentially decaying inlet-duct concentration. Numerical methods resulted in normalized error of less than 10 -9 when model solutions were compared to analytical solutions. The model was validated against experimental measurements from a single field test and showed good agreement in the shape and magnitude of the aerosol concentration profile with time.

54 ENVIRONMENTAL SCIENCES↗

Filtration testing for enhanced performance of Radionuclide Monitoring Stations for Nuclear Treaty Verification

A study of aerosol filtration was conducted to improve U.S. Radionuclide Monitoring Station (RMS) performance for Nuclear Treaty Verification. The primary objectives of this study were to improve system operability and maintainability, reduce power consumption and operational cost, and reduce baseline radionuclide sensitivity. To meet these goals, Sandia National Laboratories (SNL) studied the performance of alternate filter materials and aerosol collection technologies that could be engineered into U.S. Radionuclide Monitoring Stations. Laboratory-scale filtration experiments were conducted with Filter Material 1, FM1 (current filter), Filter Material 2, FM2, and Filter Material 3, FM3. All three materials employ electrostatically charged filter fibers to enhance nanoparticle collection. FM2 and FM3 both had higher air permeability with respect to FM1 which is advantageous for high volume collection and power savings. Particle pre-charging, a well-established industrial technique used in electrostatic precipitators, was tested to see if electrostatically charging particles prior to filtration could enhance filter performance. We found that particle-pre-charging did enhance aerosol collection efficiencies for materials which would not have otherwise satisfied RMS performance requirements. Laboratory-scale testing indicated it may be possible to reduce the baseline radionuclide sensitivity to approximately 60% of its current value by increasing the volume of air sampled in 24 hours to 2.5 times the current air volume. Improvements to geolocation may also be possible with shorter air samples (e.g., 12 hours). A new methodology was developed at SNL to assess filter performance using established RMS certification procedures. We coined these tests “mid-scale” since they bridged the gap between laboratory-scale and full-scale RMS testing. Four filter specimens were drawn from the exact same atmospheric aerosol. Gamma spectroscopy was used to assess radiological backgrounds due to radon progeny and other naturally occurring radionuclides. Direct comparisons between the four filters allowed SNL to quantify the relative change in baseline sensitivity by altering air flow rate, filter material, and particle-pre charging. Mid-scale results agreed with laboratory-scale results: alterations to RMS configuration (filter, flow, and particle charge) may result in baseline sensitivities approximately 55-60% of their current values. Finally, an assessment of scalability was performed to determine if technical approaches used in laboratory-scale and mid-scale testing could be engineered into full-scale Radionuclide Monitoring Stations. Results suggested that particle-pre-charging is a viable technical approach if reductions in baseline sensitivity or power consumption are desired.

54 ENVIRONMENTAL SCIENCES↗