Engineering Papers⌕ Search

Engineering topics

Huang, C

Publications and source records attributed to Huang, C.

At least 19 records

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

Grid Data Crossing Platform (GriD-Xing)

This project is to develop a data management and analytics platform called Grid Data Crossing (GriD-Xing) that integrates data processing, storage, analysis, and visualization functionalities for users at industry (e.g., EMS and DMS) and universities. It intends to increase the applicability of large set of multi-source data (e.g., SCADA, PMU, μPMU, AMI, inverter, load/DER forecasting, and cyber data) and eventually improve the resilience, reliability, and security of critical energy infrastructure. GriD-Xing also intends to be a research platform to identify the usefulness of large multi-source data via case studies of interest to industry (e.g., 2011 southwest cold weather and 2016 Blue Cut fire events). In the first year, the team focused on the development and demonstration of large multi-source data (e.g., PMU, μPMU, SCADA, AMI, and cyber data) processing, storage, and analysis. Specifically, the team designed GriD-Xing framework in functional and structural aspects, developed GriD-Xing algorithms for large multi-source grid data processing, storage, and analysis, and finally demonstrated GriD-Xing prototype algorithms performance through a series of tests and case studies using real-world and simulation data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TH-AB-202-10: Quantifying the Accuracy and Precision of Six Degree-Of-Freedom Motion Estimation for Use in Real-Time Tumor Motion Monitoring During Radiotherapy

Purpose: Kilovoltage intrafraction monitoring (KIM) scheme has been successfully used to simultaneously monitor 3D tumor motion during radiotherapy. Recently, an iterative closest point (ICP) algorithm was implemented in KIM to also measure rotations about three axes, enabling real-time tracking of tumor motion in six degrees-of-freedom (DoF). This study aims to evaluate the accuracy of the six DoF motion estimates of KIM by comparing it with the corresponding motion (i) measured by the Calypso; and (ii) derived from kV/MV triangulation. Methods: (i) Various motions (static and dynamic) were applied to a CIRS phantom with three embedded electromagnetic transponders (Calypso Medical) using a 5D motion platform (HexaMotion) and a rotating treatment couch while both KIM and Calypso were used to concurrently track the phantom motion in six DoF. (ii) KIM was also used to retrospectively estimate six DoF motion from continuous sets of kV projections of a prostate, implanted with three gold fiducial markers (2 patients with 80 fractions in total), acquired during the treatment. Corresponding motion was obtained from kV/MV triangulation using a closed form least squares method based on three markers’ positions. Only the frames where all three markers were present were used in the analysis. The mean differences between the corresponding motion estimates were calculated for each DoF. Results: Experimental results showed that the mean of absolute differences in six DoF phantom motion measured by Calypso and KIM were within 1.1° and 0.7 mm. kV/MV triangulation derived six DoF prostate tumor better agreed with KIM estimated motion with the mean (s.d.) difference of up to 0.2° (1.36°) and 0.2 (0.25) mm for rotation and translation, respectively. Conclusion: These results suggest that KIM can provide an accurate six DoF intrafraction tumor during radiotherapy.

60 APPLIED LIFE SCIENCES↗