Engineering Papers⌕ Search

Engineering topics

Hua, Liwei

Publications and source records attributed to Hua, Liwei.

A Microwave Photonics Optical Fiber Method for Measuring Distributed Strain for Hydrologic Applications in the Vadose and Saturated Zones

Distributed strain measurements appear to hold significant potential for monitoring hydrologic processes. Coherence-length-gated Microwave Photonics Interferometry (CMPI) is a distributed sensing technique that measures strain in an optical fiber by reading optical interference phase changes in the microwave domain. The technique provides 10nε resolution when cm spatial resolution is applied. CMPI was used to measure the strain caused by small periodic variations in air pressure (25 Pa amplitude and 4 Hz) in a sand-filled laboratory column used to represent barometric loading in the vadose zone. The strain varied as a periodic function with an amplitude that decreased and a phase that increased with depth. The distribution of amplitude and phase of the strain depended on the water saturation, permeability, and presence of a barrier at the top of the sand. A theoretical analysis suggests that the air pressure diffusivity estimated from pressure data is similar to the diffusivity estimated from the distributed strain. These results indicated that the CMPI distributed strain measurement system could be used to improve monitoring and characterization of the vadose and underlying saturated zone.

Hua, Liwei↗

Case report: Fatal Legionella infection diagnosed via by metagenomic next-generation sequencing in a patient with chronic myeloid leukemia

Legionella is an aerobic, gram-negative, intracellular pathogen and is an important cause of community-acquired pneumonia. Legionella pneumophila is the most common causative agent of Legionella pneumonia. Clinical diagnosis of Legionella pneumonia is challenging due to the lack of specific clinical manifestations and the low positive rates of conventional pathogen detection methods. In this study, we report a case of a patient with chronic myeloid leukemia who developed rigors and high fever after chemotherapy and immunotherapy. Chest computed tomography revealed consolidation in the left lower lobe of the lung and ground-glass opacities in both lower lobes. Multiple blood cultures showed Escherichia coli , Staphylococcus aureus , Bacillus licheniformis , and positive results in the β-D-glucan test (G test). The patient was treated with various sensitive antimicrobial agents, including meropenem plus fluconazole, meropenem plus carpofungin, and vancomycin. Unfortunately, the patient’s condition gradually worsened and eventually resulted in death. On the following day of death, metagenomic next-generation sequencing (mNGS) of 1whole blood revealed L. pneumophila pneumonia with concurrent bloodstream infection (blood mNGS reads 114,302). These findings suggest that when conventional empirical antimicrobial therapy proves ineffective for critically ill patients with pneumonia, the possibility of combined Legionella infection must be considered, and mNGS can provide a diagnostic tool in such cases.

Bu, Chunhong↗

PW2 Pumping: March 18 thru March 22, 2020

Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m

Distributed Strain Sensing↗

Robust In-Situ Strain Measurements to Monitor CO 2 Storage

The goal of this project was to develop and demonstrate robust instrumentation to monitor the in-situ strain tensor in order to improve the reliability and security of CO 2 storage in geologic formations. We met the original goals of the project and the major overarching accomplishment is the advancement of strain tensor monitoring from an intriguing concept to a commercially available technology with a solid foundation of novel instruments supported by theoretical analyses and validation experiments. The main accomplishments of the project are summarized below. We designed, built and evaluated nine new optical fiber strainmeters and tiltmeters using Michelson interferometers to measure deformation with ultra-high resolution at both shallow and deep point locations in the subsurface. These are the robust strainmeters that motivated the title of the project. We designed, built and evaluated a novel method of measuring distributed strain in optical fibers with nanostrain resolution, and cm-scale location, and sampling into the seismic band. The new method is called Coherence-length-gated Microwave Photonics Interfereometry (CMPI). CMPI technology has advantages over existing commercial DAS and DSS methods. We developed and demonstrated capabilities to deploy instruments in the field and used them to measure strain caused by ambient signals like barometric pressure and tides, as well as induced signals like surface loading and pore pressure changes from pumping tests. We deployed a working strainmeter at 1,700 ft depth, slightly above an active reservoir. This is to our knowledge the greatest depth a strainmeter has been deployed and the techniques we used can readily be extended to greater depths. Optical fiber borehole tensor strainmeter techology was advanced from a TRL 4 at the start, to a TRL of 7 at the conclusion of the project. The project included advances in simulations and theoretical analyses. We developed and demonstrated a computational workflow that uses machine learning to reduce the computational requirements and make it practical to use Bayesian inversion to solve large numerical poroelastic analyses needed to interpret strain tensor field data. We evaluated the strain tensor fields and time series that would be caused by leaks of CO 2 or other fluids from reservoirs. These simulations demonstrated that signals from leaks could be measured with instruments developed for the project, opening a potentially new method for ensuring storage security. We showed that strains in caprock can be used to estimate pressure in a reservoir. This avoids the need to drill monitoring wells into the reservoir, and it expands the capabilities of monitoring in the caprock. The project includes a derivation and application of a novel analytical solution to the strains in the vicinity of a pressurized poroelastic inclusion. This solution explains field data measured during injeciton tests at the North Avant Field, and it will simplify future interpretation of strain tensor data. The project included a broad range of experiments, and of the most significant is the characterization of the strain tensor at an array three strainmeters during six injection tests at the North Avant Field, Oklahoma. This demonstrated repeatability of the strain signal measured by the new instruments developed for the project, and it showed similarities between the strain signal at shallow depths and pressure in the underlying reservoir. We also demonstrated that useful strain data can be measured at reservoir depths. This confirms that strain tensor data can be measured throughout the caprock over a reservoir. The project demonstrated the feasibility of using the strain tensor and distributed strain measured in caprock during a variety of different well tests where the pumping rate was constant, sinusoidal and positive, or a periodic square wave with zero net rate. This further strengthens the validity of using strain data to characterize reservoirs and aquifers. We also demonstrated that strain caused be fluctuations of air pressure and water pressure in the vadose zone can be measured and interpreted, suggesting that high resolution distributed strain measurements hold promise for monitoring the vadose zone. The project partially supported nine graduate students in the Environmental Engineering, Hydrogeology, Electrical Engineering programs at Clemson University. The research was described in nine journal papers, 23 talks and conference abstracts. Additional journal papers are in preparation. A new company called Tensora was started to provide strainmeter technology for commercial applications.

01 COAL, LIGNITE, AND PEAT↗

Damage detection in a laboratory-scale wellbore applying Time Reversal and Nonlinear Elastic Wave Spectroscopy (TR NEWS)

We report Time Reversal and Nonlinear Elastic Wave Spectroscopy (TR-NEWS) has been used to focus acoustic energy, and make measurements correlated with damage in a variety of industrial materials. Most studies using TR-NEWS have focused on relatively small objects and may have multiple acoustic sources. In Earth, within energy extraction and carbon sequestration settings, the structure and scale of wellbores makes acoustic focusing challenging, as has been demonstrated through numerical simulations. This paper explores the feasibility of applying TR NEWS for damage detection in wellbores by constructing a laboratory-scale wellbore, and using TR to focus and make dynamic linear and nonlinear elastic measurements on it. During successive cycles of localized mechanical damage induced in the sample, the hysteretic nonlinear elastic parameter α increased with progressive mechanical damage. In addition to these strain-dependent changes in α, the width and peak amplitude of the time reversal focused energy changed near the damage site.

58 GEOSCIENCES↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

A Type–Curve Approach for Evaluating Aquifer Properties by Interpreting Shallow Strain Measured During Well Tests

Strains occur at shallow depths in response to pressure changes during well tests in an underlying aquifer, and recent developments in instrumentation have made it feasible to measure essentially the full strain tensor. Simulations using poroelastic analyses indicate that shallow normal strains are approximately proportional to the logarithm of time when a well is injecting into or pumping from a deep aquifer or reservoir. The drawdown is also a linear function of log time, as shown by the classic Cooper-Jacob type-curve analysis. The time when the semilog straight line intercepts the zero-strain axis is similar to the time determined from the Cooper-Jacob pressure analysis, and it can be used to estimate hydraulic diffusivity, suggesting that horizontal strain data can be used directly to estimate aquifer properties. This approach was validated using measurements from shallow (30-m deep) borehole strainmeters during an injection test at a 530-m-deep sandstone aquifer/reservoir in Oklahoma. The results show intercept times for the shallow normal strain data are essentially the same as for deep pressure data from an equivalent radial distance. The slopes of the semilog plots of the pressure and the strain increase at the same time, suggesting that they both respond to a lateral aquifer boundary. Significantly, though, strain was measured at shallow depths while the pressure data were measured at 530-m depth. This suggests that strain data from shallow depths could be an effective way to improve the characterization of an underlying aquifer.

54 ENVIRONMENTAL SCIENCES↗