Engineering Papers⌕ Search

Engineering topics

Hoover, Richard B.

Publications and source records attributed to Hoover, Richard B..

At least 145 records · Page 8

The Objective Double Crystal Spectrometer

The solar corona, supernova remnants, the hot diffuse interstellar gas in the Galaxy, galactic halos, and the hot intracluster gas in rich clusters of galaxies, are examples of extended astrophysical plasmas which emit line-rich spectra in the X-ray spectral range from 1.5 to 25 A. These phenomena represent a significant fraction of the baryonic matter in the universe. The study of the composition, structure and dynamics of these astrophysical plasmas requires observations with both high spectral and spatial resolution simultaneously. The Objective Double Crystal Spectrometer, coupled with a grazing incidence X-ray telescope, represents a stigmatic instrument which is highly efficient for the study of such sources. We describe the configuration and performance (spatial resolution, spectral resolution and efficiency) of the Objective Double Crystal spectrometer.

Walker, Arthur B. C., Jr.↗

Ultra-High-Spectral-Resolution X-Ray/EUV Monochromator

Ultra-high-spectral-resolution X-Ray/EUV monochromator depends on Bragg reflection from multilayer coats and diffraction by mutlilayer-coated grating to select narrow wavelength band from input beam. Its monochromatic output beam of accurately known wavelength very useful in testing and calibration of x-ray telescopes, x-ray microscopes, photographic films, and photodetectors; in research in biological and biomedical disciplines, x-ray crystallography, properties and processing of materials, and x-ray lasers; and in x-ray lithography.

Hoover, Richard B.↗

Telescope Would Image X And Gamma Rays

Proposed telescope forms images of sources of gamma rays, hard x rays, and soft x rays. Contains reflecting, grazing-incidence reflectors. Multiple coaxial nested pairs used to form images simultaneously at multiple gamma-ray or hard x-ray energies or enhance collection area at single photon energy. Conceived for use in astrophysical studies in outer space. With modifications, used in terrestrial laboratory vaccum systems to image x or gamma rays from pulsed plasmas.

Hoover, Richard B.↗

Microscope Would Image X and Gamma Rays

Microscope contains Bragg-reflecting, grazing-incidence reflectors, filter wheel, and detector. Multiple nested coaxial pairs of reflectors used to form images simultaneously at multiple wavelengths. Collects and focuses radiation to produce images with moderate spectral resolution and high spatial resolution. Enables use of smaller, cheaper, better-shielded detectors. Combination of features provides new information of unprecedented value in several fields of research; probing fine structures of pulsed plasmas, investigating minute variations in structures of material specimens penetrated only by hard-x or gamma rays, or in producing maps of distributions of radioisotopes in biological specimens.

Hoover, Richard B.↗

Multi-Spectral Solar Telescope Array. II - Soft X-ray/EUV reflectivity of the multilayer mirrors

The Multispectral Solar Telescope Array is a rocket-borne observatory which encompasses seven compact soft X-ray/EUV, multilayer-coated, and two compact far-UV, interference film-coated, Cassegrain and Ritchey-Chretien telescopes. Extensive measurements are presented on the efficiency and spectral bandpass of the X-ray/EUV telescopes. Attention is given to systematic errors and measurement errors.

Barbee, Troy W., Jr.↗

Design and analysis of aspherical multilayer imaging X-ray microscope

Spherical Schwarzschild microscopes for soft X-ray applications in microscopy and projection lithography employ two concentric spherical mirrors that are configured such that the third-order spherical aberration and coma are zero. Based on incoherent, sine-wave MTF calculations, the object-plane resolution of a magnification-factor-20 microscope is presently analyzed as a function of object height and numerical aperture of the primary for several spherical Schwarzschild, conic, and aspherical two-mirror microscope configurations.

Shealy, David L.↗

EUV/FUV response characteristics of photographic films for the Multi-Spectral Solar Telescope Array

The photographic film employed by NASA's Multi-Spectral Solar Telescope Array must have high-to-ultrahigh resolution; since the spacecraft bearing the telescope must be evacuated to prevent the failure of delicate EUV and soft X-ray filters due to acoustic vibration during launch, the films must also have very low outgassing rates. An account is presently given of the properties of important new emulsions selected for flight, together with response-characteristics data for the experimental XUV 100 film and an uncoated Spectroscopic 649 emulsion.

Hoover, Richard B.↗

Multi-Spectral Solar Telescope Array. V - Temperature diagnostic response to the optically thin solar plasma

The compact soft X-ray/EUV/FUV multilayer coated telescopes developed for solar chromosphere, corona, and corona/solar-wind interface studies permit the use of conventional (Cassegrain, Herschelian, etc.) configurations. The multilayer coatings also allow a narrow-wavelength band to be selected for imaging. NASA's Multi-Spectral Solar Telescope Array is composed of 17 of these compact telescopes; attention is given to their ability to obtain temperature-diagnostic information concerning the solar plasma.

Deforest, Craig E.↗

Multi-Spectral Solar Telescope Array. IV - The soft X-ray and extreme ultraviolet filters

NASA's Multi-Spectral Solar Telescope Array uses various combinations of thin foil filters composed of Al, C, Te, Be, Mo, Rh, and phthalocyanine to achieve the requisite radiation-rejection characteristics. Such rejection is demanded by the presence of strong EUV radiation at longer wavelengths where the specular reflectivity of multilayer mirrors can cause 'contamination' of the image in the narrow band defined by the Bragg condition.

Lindblom, Joakim F.↗

Polarimetry of extreme ultraviolet lines in solar astronomy

Ways are suggested in which recent advancements in the fabrication of ultrasmooth, low scatter flow-polished mirror substrates and high-quality multilayer and interference film coatings can be used to create novel optical instruments for observing linear-polarization effects in the outer solar atmosphere. Attention is given to the observational parameters of all-reflective FUV/EUV imaging polarimeters; such a coronagraph/polarimeter, operating at Ly-alpha, could yield the first measurements of coronal vector magnetic fields.

Fineschi, Silvano↗

Imaging polarimeters for solar extreme ultraviolet astronomy

Accounts are given of EUV/FUV polarimetric instrument concepts for solar research which observe linear polarization in the spectral lines which originate in the outer solar atmosphere. The coronagraph/polarimeter instruments discussed employ all-reflective optical systems using ultrasmooth, low-scatter normal incidence mirrors and reflective polarization analyzers. The reflecting polarization analyzers operate at the Brewster angle.

Hoover, Richard B.↗

Imaging Microscope For "Water-Window" X Rays

Proposed microscope operates in "water-window" part of x-ray spectrum. Contains spherical-mirror substrates coated with multiple thin layers of material exhibiting Bragg reflection at wavelength at which water transparent. Suited for making high-resolution, high-contrast images for microbiological research.

Hoover, Richard B.↗

X ray microscope/telescope test and alignment

The tasks performed by the Center for Applied Optics (CAO) in support of the Normal Incidence Multilayer X-Ray Optics Program are detailed. The Multi-Spectral Solar Telescope Array (MSSTA) was launched on a Terrier-boosted Black Brant sounding rocket from White Sands Missile Range on 13 May 1991. High resolution images of the sun in the soft x ray to extreme ultraviolet (EUV) regime were obtained with normal-incidence Cassegrain, Ritchey-Chretien, and Herschelian telescopes mounted in the sounding rocket. MSSTA represents the first use of multilayer optics to study a very broad range of x ray and EUV solar emissions. Energy-selective properties of multilayer-coated optics allow distinct groups of emission lines to be isolated in the solar corona and transition region. Features of the near and far coronal structures including magnetic loops of plasmas, coronal plumes, coronal holes, faint structures, and cool prominences are visible in these images. MSSTA successfully obtained unprecedented information regarding the structure and dynamics of the solar atmosphere in the temperature range of 10(exp 4)-10(exp 7) K. The performance of the MSSTA has demonstrated a unique combination of ultra-high spatial resolution and spectral differentiation by use of multilayer optics.

Walker, Arthur B. C.↗

Four-Mirror X-Ray And Extreme-Ultraviolet Monochromator

More mirrors provide additional wavelength selectivity. Four-mirror x-ray and extreme-ultraviolet monochromator provides narrower wavelength passband than devices described in "Compact X-Ray and Extreme Ultraviolet Monochromator" (MFS-28499) and "Scanning X-Ray or Extreme Ultraviolet Monochromator" (MFS-28492). Relies on Bragg reflection from two identical parallel multilayer mirrors to extract narrow-spectrum x-ray or extreme-ultraviolet beam from broad-spectrum input beam.

Hoover, Richard B.↗

Compact X-Ray And Extreme-Ultraviolet Monochromator

Monochromator for x-ray and extreme-ultraviolet radiation provides higher spectral resolution than achieved with thin-metal-foil broad-band-pass filters. Uses Bragg reflection to band-pass-filter radiation from high-intensity, broad-spectrum source. Operates over much broader x-ray and extreme-ultraviolet spectrum than devices based upon natural crystals. Intended to filter continuum radiation from sources like synchrotrons, laser plasma sources, free-electron lasers, and wigglers to produce monochromatic beams for testing and analysis of x-ray and extreme-ultraviolet telescopes and microscopes, for calibration of photographic films and detectors, for biological and biomedical research, for x-ray lithography, for processing of materials, and for research in properties of materials.

Hoover, Richard B.↗

Variable magnification variable dispersion glancing incidence imaging x-ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x-ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x-ray and extreme ultraviolet radiation sources includes a pirmary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carries each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a mutlilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x-ray sensitive photogrpahic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard B.↗

X ray imaging microscope for cancer research

The NASA technology employed during the Stanford MSFC LLNL Rocket X Ray Spectroheliograph flight established that doubly reflecting, normal incidence multilayer optics can be designed, fabricated, and used for high resolution x ray imaging of the Sun. Technology developed as part of the MSFC X Ray Microscope program, showed that high quality, high resolution multilayer x ray imaging microscopes are feasible. Using technology developed at Stanford University and at the DOE Lawrence Livermore National Laboratory (LLNL), Troy W. Barbee, Jr. has fabricated multilayer coatings with near theoretical reflectivities and perfect bandpass matching for a new rocket borne solar observatory, the Multi-Spectral Solar Telescope Array (MSSTA). Advanced Flow Polishing has provided multilayer mirror substrates with sub-angstrom (rms) smoothnesss for the astronomical x ray telescopes and x ray microscopes. The combination of these important technological advancements has paved the way for the development of a Water Window Imaging X Ray Microscope for cancer research.

Hoover, Richard B.↗