CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Framework to select robust energy retrofit measures for residential communities

Residential building energy retrofits are essential for enhancing environmental sustainability and reducing energy costs. The selection of retrofit measures is influenced by factors such as building systems, occupant behavior, government policy, weather variability, and climate change, all of which can significantly impact energy performance. Compared to retrofitting individual homes, evaluating and selecting optimal retrofit solutions for an entire community is challenging due to diverse residential compositions and variability present. Therefore, engineering robustness is crucial for ensuring consistent energy performance and resilience across different conditions. In this context, robustness refers to the ability of a retrofit measure to maintain its functionality and remain an optimal choice despite external disturbances or changes in inputs and conditions. This study presents a framework for evaluating the robustness of multiple retrofit measures across various building systems, occupant behaviors, and environmental scenarios at the community level. The framework comprises five key steps: scenario model development, integration of the National Residential Efficiency Measures database, energy performance simulation, cost-benefit aggregation, and retrofit solution selection. Each step enhances the framework’s robustness by incorporating the diversity of building characteristics, occupant behaviors, environmental conditions, retrofit options, and evaluation criteria. The framework’s effectiveness is demonstrated through a case study in southern Michigan in the United States, which includes 63 one-story single-family houses, 121 two-story single-family houses, and 8 townhouses. The study identifies furnace retrofits as the most robust solution for the entire community, consistently achieving source energy reductions of 4.7 %–8.0 % and payback period of 10–20 years across various scenarios. These findings are consistent with previous research, indicating the framework’s potential for broader applications in optimizing community-scale residential energy retrofits.

Shu, Lei

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man

Cities Are Concentrators of Complex, MultiSectoral Interactions Within the Human-Earth System

Cities are concentrators of complex, multi-sectoral interactions. As keystones in the interconnected human-Earth system, cities have an outsized impact on the Earth system. We describe a multi-lens framework for organizing our understanding of the complexity of urban systems and scientific research on urban systems, which may be useful for natural system scientists exploring the ways their work can be made more actionable. We then describe four critical dimensions along which improvements are needed to advance the urban research that addresses urgent climate challenges: (a) solutions-oriented research, (b) equity-centered assessments which rely on fine-scale human and ecological data, (c) co-production of knowledge, and (d) better integration of human and natural systems occurring through theory, observation, and modeling.

54 ENVIRONMENTAL SCIENCES

The hidden costs of concealing outdoor air conditioning units

The beautification of urban facades in China often includes covers for the outdoor units of air conditioners. Although these covers improve cityscapes, they reduce cooling efficiency, increase noise pollution, risk system failures and embody carbon emissions. A call urges rethinking their necessity, and presses for sustainable, efficient design to counteract extreme heat.