Engineering Papers⌕ Search

Engineering topics

Holmes, D.

Publications and source records attributed to Holmes, D..

At least 19 records

Thermal Analysis and Simulations of the Abort Kicker Magnets Systems for the Electron-Ion Collider

The Abort Kicker Magnets system used in the current Relativistic Heavy Ion Collider (RHIC) to steer the circulating beam into the dump will be subjected to higher heat loads in the Electron-Ion Collider (EIC). After analyzing the existing abort kicker magnets and running thermal simulations in ANSYS it was concluded that they may not be suitable for use as-is in the future EIC due to heat and impedance concerns in the magnets. Possible solutions include adding a round titanium-coated ceramic beam tube to help solve the heat and impedance concerns, but this will reduce the limiting aperture of the kicker magnet. Another possible solution to meet all the performance requirements for EIC would be to add titanium-coated ceramic plates with water-cooling and tapered transitions that significantly improve the impedance and lower the heat in the magnets with less reduction to the aperture.

43 PARTICLE ACCELERATORS↗

The Electromagnetic Design of the X/Y line Combined Function Magnets

This technical note presents the electromagnetic design of the combined function magnets which make up the FODO array of the X-line or Y-line magnets of the AGS to RHIC (AtR) transfer line. Prior to the presentation of the electromagnetic design of the combined function magnets a brief section will be devoted to familiarize the reader with the use of the combined function magnets which make up the elements of the X and Y lines of the AtR line.

43 PARTICLE ACCELERATORS↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

Design and Prototyping of the Electron Ion Collider Electron Storage Ring 591 MHz Elliptical SRF Cavity

The Electron Ion Collider (EIC) is a new nuclear phys-ics research facility to be constructed at Brookhaven Lab (BNL). It consists a few accelerator complexes, each re-quires some different SRF and RF systems. Among them, the electron storage ring?s (ESR) 591 MHz fundamental RF system is one of the most challenging. This 17 cavi-ties system will handle a variable beam current of up to 2.5 A, and replenish up to 10 MW of beam power losses from both synchrotron radiation (SR) and high-order modes (HOM). In this paper, we will report the progress and findings of the ongoing design and prototyping of this cavity.

Guo, J.↗

High Power Test Results For A Cylindrical-Shell SiC Higher-Order-Mode DAMPER

The next high-current Electron Ion Collider (EIC) is a new accelerator to be built at Brookhaven National Laboratory (BNL) in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). In the EIC Electron Storage Ring (ESR), there will be beam currents up to 2.5 A, which will excite massive Higher-Order-Modes (HOM) power in the 17 single-cell 591 MHz Superconducting Radio Frequency (SRF) cavities. To damp the HOM power in the ESR SRF cavities is a challenge. A room temperature cylindrical shell shape Silicon Carbide (SiC) Beamline HOM Absorber (BLA) was chosen as the baseline design, due to its broadband and high-power capability, and previous demonstrations at other accelerator facilities, albeit at much lower power. Because the EIC BLA HOM power dissipation is significantly greater than the previous applications, it is imperative to carry out high power testing to determine the maximum device performance levels achievable for thermal transport, RF breakdown, and mechanical stress, prior to finalizing the design. A SiC HOM absorber with state-of-the-art geometry size was prototyped to verify shrink-fit technique, test outgassing rate, and high power handling capability. This paper presents the HOM damper’s prototyping and test results.

43 PARTICLE ACCELERATORS↗

Beam Induced Heating Analysis Update for the EIC Vacuum Chamber Components

One of the challenges of designing the Electron-Ion Col lider (EIC) is to mitigate beam-induced heating due to the intense electron and hadron beams. Heating of the ESR vac uum chamber components is mainly due to beam-induced resistive wall (RW) losses and synchrotron radiation. For the HSR heating is mainly due to large radial offsets and heat conduction from room temperature to cryogenic tem perature for cryo-components. In this paper, we provide an update on the beam-induced heating and thermal analysis of some critical ESR vacuum chamber components, such as the ESR Large Angle Bremhustraulung Monitor (LABM). We also provide a similar update for critical HSR vacuum com ponents, including the cryo-cooled BPM button assembly, beam screen, abort kicker, and polarimeter. To perform the thermal analyses, the resistive wall loss on individual compo nents is calculated with CST and the synchrotron radiation (if exists) is evaluated using SynRad. These losses, along with realistic boundary conditions are then fed to ANSYS to determine the temperature distribution.

43 PARTICLE ACCELERATORS↗

Lattice Design of the EIC Electron Storage Ring for Energies Down to 5 GeV

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory will feature an electron storage ring that will circulate polarized beams with energies up to 18 GeV. Recently a study has been undertaken to extend the minimum energy from 6 GeV to 5 GeV. As the solenoid-based spin rotators around the interaction point require specific bending angles that depend on the energy range, this change results in major changes to the geometry. Moreover, avoiding interference of the electron beamline with the other beamlines in the tunnel, as well as with the tunnel walls, is a formidable challenge, especially at the location of the large-diameter superconducting solenoids. In this contribution, the details of the modified spin rotators, geometrical layout, and optics of the revised lattice are presented.

43 PARTICLE ACCELERATORS↗

Cavity and Cryomodule Developements for EIC

The EIC is a major new project under construction at BNL in partnership with JLab. It relies upon a number of new SRF cavities at 197 MHz, 394 MHz, 591 MHz and 1773 MHz to pre-bunch, accelerate, cool and crab the stored beams. R&D is focusing on the 591 MHz elliptical cavity and 197 MHz crab cavity first as these are the most challenging. Preliminary designs of these cavities are presented along with an R&D status report. To avoid developing multiple different cryostats a modular approach is adopted using a high degree of commonality of parts and systems. This approach may be easily adapted to other frequencies and applications.

Rimmer, R.A.↗

Electron-Ion Collider Design Status

The Electron-Ion Collider (EIC) is being designed for construction at Brookhaven National Laboratory. Activities have been focused on beam-beam simulations, polarization studies, and beam dynamics, as well as on maturing the layout and lattice design of the constituent accelerators and the interaction region. The latest design advances will be presented.

43 PARTICLE ACCELERATORS↗

OPTICS FOR STRONG HADRON COOLING IN EIC HSR-I

Insertion Region 2 (IR2) of the Relativistic Heavy Ion Collider will be modified to accommodate a Strong Hadron Cooling facility in the Hadron Storage Ring (HSR) of the Electron-Ion Collider (EIC). This paper describes the current proof-of-principle design of HSR-IR2 - layout, optical performance, design methodology, and engineering requirements. It also describes the challenges and opportunities in the future development of the HSR-IR2 design, in order to further optimize Strong Hadron Cooling performance.

Peggs, S.↗

Design of the Electron Ion Collider Electron Storage Ring SRF cavity

The Electron Ion Collider (EIC) under construction at Brookhaven National Laboratory is a high luminosity collider as the next major research facility for the nuclear physics community. Among the numerous RF subsystems in the EIC, the electron storage ring (ESR) fundamental RF cavities system is one of the most challenging. This system will handle a high beam current of up to 2.5A and replenish up to 10MW of beam power losses from synchrotron radiation and HOM. Variable coupling is required in the cavities due to the wide range of required total RF voltage and beam current combinations. In this paper, we will present the status of the design and future plans.

Guo, J.↗

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

Design Status Update of the Electron-Ion Collider

The design of the electron-ion collider EIC to be constructed at Brookhaven National Laboratory has been continuously evolving towards a realistic and robust design that meets all the requirements set forth by the nuclear physics community in the White Paper. Over the past year activities have been focused on maturing the design, and on developing alternatives to mitigate risk. These include improvements of the interaction region design as well as modifications of the hadron ring vacuum system to accommodate the high average and peak beam currents. Beam dynamics studies have been performed to determine and optimize the dynamic aperture in the two collider rings and the beam-beam performance. We will present the EIC design with a focus on recent developments.

43 PARTICLE ACCELERATORS↗

Studies of the Imperfection in Crab Crossing Scheme for Electron-Ion Collider

Crab crossing scheme is the essential scheme that accommodates large crossing angle without loss of luminosity in the design of Electron-Ion collider (EIC). The ideal optics and phase advances of the crab cavity pair are set to create a local crabbing bump in the interaction region (IR). However, there are always small errors in the actual lattice of IR. In this article, we will present the simulation and analytical studies on the imperfections in the crab crossing scheme in the EIC design. The tolerance of the imperfection and the possible remedies can be concluded from these studies.

Hao, Y.↗