Engineering Papers⌕ Search

Engineering topics

Hollis, Brian R.

Publications and source records attributed to Hollis, Brian R..

64 records · Page 4

X-33 Aerodynamic and Aeroheating Computations for Wind Tunnel and Flight Conditions

This report provides an overview of hypersonic Computational Fluid Dynamics research conducted at the NASA Langley Research Center to support the Phase II development of the X-33 vehicle. The X-33, which is being developed by Lockheed-Martin in partnership with NASA, is an experimental Single-Stage-to-Orbit demonstrator that is intended to validate critical technologies for a full-scale Reusable Launch Vehicle. As part of the development of the X-33, CFD codes have been used to predict the aerodynamic and aeroheating characteristics of the vehicle. Laminar and turbulent predictions were generated for the X 33 vehicle using two finite- volume, Navier-Stokes solvers. Inviscid solutions were also generated with an Euler code. Computations were performed for Mach numbers of 4.0 to 10.0 at angles-of-attack from 10 deg to 48 deg with body flap deflections of 0, 10 and 20 deg. Comparisons between predictions and wind tunnel aerodynamic and aeroheating data are presented in this paper. Aeroheating and aerodynamic predictions for flight conditions are also presented.

Hollis, Brian R.↗

Transition Effects on Heating in the Wake of a Blunt Body

A series of aerodynamic heating tests was conducted on a 70-deg sphere-cone planetary entry vehicle model in a Mach 10 perfect-gas wind tunnel at freestream Reynolds numbers based on diameter of 8.23x104 to 3.15x105. Surface heating distributions were determined from temperature time-histories measured on the model and on its support sting using thin-film resistance gages. The experimental heating data were compared to computations made using an axisymmetric/2D, laminar, perfect-gas Navier-Stokes solver. Agreement between computational and experimental heating distributions to within, or slightly greater than, the experimental uncertainty was obtained on the forebody and afterbody of the entry vehicle as well as on the sting upstream of the free-shear-layer reattachment point. However, the distributions began to diverge near the reattachment point, with the experimental heating becoming increasingly greater than the computed heating with distance downstream from the reattachment point. It was concluded that this divergence was due to transition of the wake free shear layer just upstream of the reattachment point on the sting.

Hollis, Brian R.↗

Experimental and Computational Aerothermodynamics of a Mars Entry Vehicle

An aerothermodynamic database has been generated through both experimental testing and computational fluid dynamics simulations for a 70 deg sphere-cone configuration based on the NASA Mars Pathfinder entry vehicle. The aerothermodynamics of several related parametric configurations were also investigated. Experimental heat-transfer data were obtained at hypersonic test conditions in both a perfect gas air wind tunnel and in a hypervelocity, high-enthalpy expansion tube in which both air and carbon dioxide were employed as test gases. In these facilities, measurements were made with thin-film temperature-resistance gages on both the entry vehicle models and on the support stings of the models. Computational results for freestream conditions equivalent to those of the test facilities were generated using an axisymmetric/2D laminar Navier-Stokes solver with both perfect-gas and nonequilibrium thermochemical models. Forebody computational and experimental heating distributions agreed to within the experimental uncertainty for both the perfect-gas and high-enthalpy test conditions. In the wake, quantitative differences between experimental and computational heating distributions for the perfect-gas conditions indicated transition of the free shear layer near the reattachment point on the sting. For the high enthalpy cases, agreement to within, or slightly greater than, the experimental uncertainty was achieved in the wake except within the recirculation region, where further grid resolution appeared to be required. Comparisons between the perfect-gas and high-enthalpy results indicated that the wake remained laminar at the high-enthalpy test conditions, for which the Reynolds number was significantly lower than that of the perfect-gas conditions.

Hollis, Brian R.↗

Real-Gas Flow Properties for NASA Langley Research Center Aerothermodynamic Facilities Complex Wind Tunnels

A computational algorithm has been developed which can be employed to determine the flow properties of an arbitrary real (virial) gas in a wind tunnel. A multiple-coefficient virial gas equation of state and the assumption of isentropic flow are used to model the gas and to compute flow properties throughout the wind tunnel. This algorithm has been used to calculate flow properties for the wind tunnels of the Aerothermodynamics Facilities Complex at the NASA Langley Research Center, in which air, CF4. He, and N2 are employed as test gases. The algorithm is detailed in this paper and sample results are presented for each of the Aerothermodynamic Facilities Complex wind tunnels.

Hollis, Brian R.↗

Comparison of Experimental and Computational Aerothermodynamics of a 70-deg Sphere-Cone

Numerical solutions for hypersonic flows of carbon-dioxide and air around a 70-deg sphere-cone have been computed using an axisymmetric non-equilibrium Navier-Stokes solver. Freestream flow conditions for these computations were equivalent to those obtained in an experimental blunt-body heat-transfer study conducted in a high-enthalpy, hypervelocity expansion tube. Comparisons have been made between the computed and measured surface heat-transfer rates on the forebody and afterbody of the sphere-cone and on the sting which supported the test model. Computed forebody heating rates were within the estimated experimental uncertainties of 10% on the forebody and 15% in the wake except for within the recirculating flow region of the wake.

Hollis, Brian R.↗

Hypervelocity Heat-Transfer Measurements in an Expansion Tube

A series of experiments has been conducted in the NASA HYPULSE Expansion Tube, in both CO2 and air test gases, in order to obtain data for comparison with computational results and to assess the capability for performing hypervelocity heat-transfer studies in this facility. Heat-transfer measurements were made in both test gases on 70 deg sphere-cone models and on hemisphere models of various radii. HYPULSE freestream flow conditions in these test gases were found to be repeatable to within 3-10%, and aerothermodynamic test times of 150 microsec in CO2 and 125 microsec in air were identified. Heat-transfer measurement uncertainty was estimated to be 10-15%. Comparisons were made with computational results from the non-equilibrium Navier-Stokes solver NEQ2D. Measured and computed heat-transfer rates agreed to within 10% on the hemispheres and on the sphere-cone forebodies, and to within 10% in CO2 and 25% in air on the afterbodies and stings of the sphere-cone models.

Hollis, Brian R.↗

User's manual for the one-dimensional hypersonic experimental aero-thermodynamic (1DHEAT) data reduction code

A FORTRAN computer code for the reduction and analysis of experimental heat transfer data has been developed. This code can be utilized to determine heat transfer rates from surface temperature measurements made using either thin-film resistance gages or coaxial surface thermocouples. Both an analytical and a numerical finite-volume heat transfer model are implemented in this code. The analytical solution is based on a one-dimensional, semi-infinite wall thickness model with the approximation of constant substrate thermal properties, which is empirically corrected for the effects of variable thermal properties. The finite-volume solution is based on a one-dimensional, implicit discretization. The finite-volume model directly incorporates the effects of variable substrate thermal properties and does not require the semi-finite wall thickness approximation used in the analytical model. This model also includes the option of a multiple-layer substrate. Fast, accurate results can be obtained using either method. This code has been used to reduce several sets of aerodynamic heating data, of which samples are included in this report.

Hollis, Brian R.↗

Hypervelocity Aeroheating Measurements in Wake of Mars Mission Entry Vehicle

Detailed measurements of aerodynamic heating rates in the wake of a Mars-Pathfinder configuration model have been made. Heating data were obtained in a conventional wind tunnel, the NASA LaRC 31" Mach 10 Air Tunnel, and in a high-enthalpy impulse facility, the NASA HYPULSE expansion tube, in which air and CO2 were employed as test gases. The enthalpy levels were 0.7 MJ/kg in the Mach 10 Tunnel, 12 MJ/kg at Mach 9.8 for HYPULSE CO2 tests and 14 MJ/kg at Mach 7.9 for HYPULSE air tests. Wake heating rates were also measured on three similar parametric configurations, and forebody heating measurements were made in order to facilitate CFD comparisons. The ratio of peak wake heating to forebody stagnation point heating in the Mach 10 Tunnel varied from 7% to 15% depending on the freestream Reynolds number. In HYPULSE, the ratio was ~5% for both air and CO 2. It was observed that an increase in the ratio of forebody corner radius to nose radius resulted in a decrease in peak wake heating, and moved the peak closer to the base of the forebody. The wake flow establishment process in HYPULSE was studied, and a method was developed to determine when the wake has become fully established.

Hollis, Brian R.↗

Real gas flow parameters for NASA Langley 22-inch Mach 20 helium tunnel

A computational procedure was developed which can be used to determine the flow properties in hypersonic helium wind tunnels in which real gas behavior is significant. In this procedure, a three-coefficient virial equation of state and the assumption of isentropic nozzle flow are employed to determine the tunnel reservoir, nozzle, throat, freestream, and post-normal shock conditions. This method was applied to a range of conditions which encompasses the operational capabilities of the LaRC 22-Inch Mach 20 Helium Tunnel. Results are presented graphically in the form of real gas correction factors which can be applied to perfect gas calculations. Important thermodynamic properties of helium are also plotted versus pressure and temperature. The computational scheme used to determine the real-helium flow parameters was incorporated into a FORTRAN code which is discussed.

Hollis, Brian R.↗

A fine-wire thermocouple probe for measurement of stagnation temperatures in real gas hypersonic flows of nitrogen

A fine-wire thermocouple probe was used to determine freestream stagnation temperatures in hypersonic flows. Data were gathered in a N2 blowdown wind tunnel with runtimes of 1-5 s. Tests were made at supply pressures between 30 and 1400 atm and supply temperatures between 700 and 1900 K, with Mach numbers of 14 to 16. An iterative procedure requiring thermocouple data, pilot pressure measurements, and supply conditions was used to determine test cell stagnation temperatures. Probe conduction and radiation losses, as well as real gas behavior of N2, were accounted for during analysis. Temperature measurement error was found to be 5 to 10 percent. A correlation was drawn between thermocouple diameter Reynolds number and temperature recovery ratio. Transient probe behavior was studied and was found to be adequate in temperature gradients up to 1000 K/s.

Hollis, Brian R.↗