Engineering Papers⌕ Search

Engineering topics

Hollinger, R.

Publications and source records attributed to Hollinger, R..

Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas

Here, we demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 10 18 W/cm 2 ) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 10 18 W/cm 2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (10 11 W/cm 2 ) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.

47 OTHER INSTRUMENTATION↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Ablating Ion Velocity Distributions in Short-Pulse-Heated Solids via X-Ray Doppler Shifts

Solids ablate under laser irradiation, but experiments have not previously characterized the initiation of this process at ultrarelativistic laser intensities. Here, we present first measurements of bulk ion velocity distributions as ablation begins, captured as a function of depth via Doppler-shifted x-ray line emission from two viewing angles. Bayesian analysis indicates that bulk ions are either nearly stationary or flowing outward at the plasma sound speed. The measurements quantitatively constrain the laser-plasma ablation mechanism, suggesting that a steplike electrostatic potential structure drives solid disassembly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Homogeneous, Micron-Scale High-Energy-Density Matter Generated by Relativistic Laser-Solid Interactions

Short-pulse, laser-solid interactions provide a unique platform for studying complex high-energy-density mat ter. We present the first demonstration of solid density, micron-scale keV plasmas uniformly heated by a high contrast, 400 nm laser at intensities up to 2×10 21 W/cm 2 . High-resolution spectral analysis of X-ray emission reveals uniform heating up to 3.0 keV over 1 µm depths. Particle-in-cell simulations indicate the production of a uniformly heated keV plasma to depths of 2 µm. The significant bulk heating and presence of highly-ionized ions deep within the target are attributed to the few MeV hot electrons that become trapped and undergo refluxing within the target sheath fields. In conclusion, these conditions enable the differentiation of atomic physics models such as ionization potential depression in high energy density environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum laser acceleration of super-ponderomotive electrons using relativistic transparency injection

Abstract Intense lasers can accelerate electrons to very high energy over a short distance. Such compact accelerators have several potential applications including fast ignition, high energy physics, and radiography. Among the various schemes of laser-based electron acceleration, vacuum laser acceleration has the merits of super-high acceleration gradient and great simplicity. Yet its realization has been difficult because injecting free electrons into the fast-oscillating laser field is not trivial. Here we demonstrate free-electron injection and subsequent vacuum laser acceleration of electrons up to 20 MeV using the relativistic transparency effect. When a high-contrast intense laser drives a thin solid foil, electrons from the dense opaque plasma are first accelerated to near-light speed by the standing laser wave in front of the solid foil and subsequently injected into the transmitted laser field as the opaque plasma becomes relativistically transparent. It is possible to further optimize the electron injection/acceleration by manipulating the laser polarization, incident angle, and temporal pulse shaping. Our result also sheds light on the fundamental relativistic transparency process, crucial for producing secondary particle and light sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid-Density Ion Temperature from Redshifted and Double-Peaked Stark Line Shapes

Heβ spectral line shapes are important for diagnosing temperature and density in many dense plasmas. This work presents Heβ line shapes measured with high spectral resolution from solid-density plasmas with minimized gradients. The line shapes show hallmark features of Stark broadening, including quantifiable redshifts and double-peaked structure with a significant dip between the peaks; these features are compared to models through a Markov chain Monte Carlo framework. Line shape theory using the dipole approximation can fit the width and peak separation of measured line shapes, but it cannot resolve an ambiguity between electron density n e and ion temperature T i , since both parameters influence the strength of quasistatic ion microfields. Here a line shape model employing a full Coulomb interaction for the electron broadening computes self-consistent line widths and redshifts through the monopole term; redshifts have different dependence on plasma parameters and thus resolve the n e – T i ambiguity. The measured line shapes indicate densities that are 80–100% of solid, identifying a regime of highly ionized but well-tamped plasma. This analysis also provides the first strong evidence that dense ions and electrons are not in thermal equilibrium, despite equilibration times much shorter than the duration of x-ray emission; cooler ions may arise from nonclassical thermalization rates or anomalous energy transport. Furthermore, the experimental platform and diagnostic technique constitute a promising new approach for studying ion-electron equilibration in dense plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of flexible proton beam imaging energy spectrometers (PROBIES)

A simple repeating step-filtered structure has been designed and deployed for the detection of MeV-energy proton beams produced from high-intensity short-pulse laser-driven experiments. Due to the diagnostic's ability to recover energy-resolved images of proton beams, it is called the proton beam imager and energy spectrometer (or PROBIES). The flexible design has two useful applications. First, it can be fielded in a configuration with a scintillator and imaging setup in order to collect proton beam information in high-repetition rate experiments. Here we show a configuration that collects the equivalent of a nine-film radiochromic film (RCF) stack, and a technique for using a neural network (NN) to rapidly analyze the images on millisecond time-scales. Second, when using RCF stacks as the detector, the energy resolution capability is greatly increased compared to traditional RCF stacks, while simultaneously reducing the total number of films required to make each measurement. We demonstrate a configuration that provides up to 90 spatially- and energy-resolved datapoints using just ten films. Both designs presented here can be easily customized for anticipated experimental outputs and manufactured at low cost. Such designs allow for rapid prototyping using modern high-accuracy 3D printers or on-demand computer numerical control machining to reduce the reliance on time-consuming film media, analysis, or bulky electro-magnetically dispersing spectrometers. The analysis of data is discussed and a methodology for constructing a NN that is capable of rapidly analyzing data on-the-fly with greater than 95% accuracy is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating the rate of discovery: toward high-repetition-rate HED science

As high-intensity short-pulse lasers that can operate at high-repetition-rate (HRR) (>10 H z ) come online around the world, the high energy density (HED) science they enable will experience a radical paradigm shift. The >10 3 increase in shot rate over today's shot-per-hour drivers translates into dramatically faster data acquisition, more experiments, and the ability to exploit machine learning, and thus the potential to significantly accelerate the advancement of HED science. A wide range of HED experiments, from opacity investigations to secondary source generation to plasma nuclear physics, will benefit from the increased statistics, precision, and exploration of phase space. Besides increasing the rate at which scientific experiments can be performed, HRR also allows for the rapid delivery of optimal experiments supported by simulations and modeling augmented by close coupling to empirical data. To fully realize such an HRR framework, numerous subsystems must be developed and brought together, including feedback laser control loops, high-throughput targetry and diagnostics, cognitive simulation, enhanced HED codes, and advanced data analytics. This paper describes the vision for an integrated HRR laser experimental HED system and outlines some of the major considerations and challenges for realizing it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing plasma conditions in short-pulse-heated foils via fine-structure x-ray emission

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. In this work, a suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

47 OTHER INSTRUMENTATION↗

Deuterated polyethylene nanowire arrays for high-energy density physics

Abstract The interaction of intense, ultrashort laser pulses with ordered nanostructure arrays offers a path to the efficient creation of ultra-high-energy density (UHED) matter and the generation of high-energy particles with compact lasers. Irradiation of deuterated nanowires arrays results in a near-solid density environment with extremely high temperatures and large electromagnetic fields in which deuterons are accelerated to multi-megaelectronvolt energies, resulting in deuterium–deuterium (D–D) fusion. Here we focus on the method of fabrication and the characteristics of ordered arrays of deuterated polyethylene nanowires. The irradiation of these array targets with femtosecond pulses of relativistic intensity and joule-level energy creates a micro-scale fusion environment that produced $2\times {10}^6$ neutrons per joule, an increase of about 500 times with respect to flat solid CD 2 targets irradiated with the same laser pulses. Irradiation with 8 J laser pulses was measured to generate up to 1.2 × 10 7 D–D fusion neutrons per shot.

Optics↗

Search for elements 119 and 120

In this work, a search for production of the superheavy elements with atomic numbers 119 and 120 was performed in the 50 Ti + 249 Bk and 50 Ti + 249 Cf fusion-evaporation reactions, respectively, at the gas-filled recoil separator TASCA at GSI Darmstadt, Germany. Over four months of irradiation, the 249 Bk target partially decayed into 249 Cf, which allowed for a simultaneous search for both elements. Neither was detected at cross-section sensitivity levels of 65 and 200 fb for the 50 Ti + 249 Bk and 50 Ti + 249 Cf reactions, respectively, at a midtarget beam energy of E lab = 281.5 MeV. The nonobservation of elements 119 and 120 is discussed within the concept of fusion-evaporation reactions including various theoretical predictions on the fission-barrier heights of superheavy nuclei in the region of the island of stability.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ion acceleration from microstructured targets irradiated by high-intensity picosecond laser pulses

Structures on the front surface of thin foil targets for laser-driven ion acceleration have been proposed to increase the ion source maximum energy and conversion efficiency. While structures have been shown to significantly boost the proton acceleration from pulses of moderate-energy fluence, their performance on tightly focused and high-energy lasers remains unclear. Here, we report the results of laser-driven three-dimensional (3D)-printed microtube targets, focusing on their efficacy for ion acceleration. Using the high-contrast (~10 12) PHELIX laser (150 J, 10 21 W / cm 2 ), we studied the acceleration of ions from 1-μm-thick foils covered with micropillars or microtubes, which we compared with flat foils. The front-surface structures significantly increased the conversion efficiency from laser to light ions, with up to a factor of 5 higher proton number with respect to a flat target, albeit without an increase of the cutoff energy. An optimum diameter was found for the microtube targets. Our findings in this work are supported by a systematic particle-in-cell modeling investigation of ion acceleration using 2D simulations with various structure dimensions. Simulations reproduce the experimental data with good agreement, including the observation of the optimum tube diameter, and reveal that the laser is shuttered by the plasma filling the tubes, explaining why the ion cutoff energy was not increased in this regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗