Engineering Papers⌕ Search

Engineering topics

Holdeman, J. D.

Publications and source records attributed to Holdeman, J. D..

At least 73 records · Page 4

GASP cloud- and particle-encounter statistics and their application to LFC aircraft studies. Volume 2: Appendixes

Summary studies are presented for the entire cloud observation archive from the NASA Global Atmospheric Sampling Program (GASP). Studies are also presented for GASP particle-concentration data gathered concurrently with the cloud observations. Cloud encounters are shown on about 15 percent of the data samples overall, but the probability of cloud encounter is shown to vary significantly with altitude, latitude, and distance from the tropopause. Several meteorological circulation features are apparent in the latitudinal distribution of cloud cover, and the cloud-encounter statistics are shown to be consistent with the classical mid-latitude cyclone model. Observations of clouds spaced more closely than 90 minutes are shown to be statistically dependent. The statistics for cloud and particle encounter are utilized to estimate the frequency of cloud encounter on long-range airline routes, and to assess the probability and extent of laminaar flow loss due to cloud or particle encounter by aircraft utilizing laminar flow control (LFC). It is shown that the probability of extended cloud encounter is too low, of itself, to make LFC impractical. This report is presented in two volumes. Volume I contains the narrative, analysis, and conclusions. Volume II contains five supporting appendixes.

Jasperson, W. H.↗

Climatology of ozone at altitudes from 19,000 at 59,000 feet based on combined GASP and ozonesonde data

A climatology of ozone for altitudes from FL190 to FL590 (19,000 to 59,000 ft) is presented. Climatological tables are given in two appendixes: one with d deg latitude resolution on a monthly basis, and one with 10 deg latitude resolution on a seasonal basis. Data were taken from 11,472 balloon-borne ozonesondes launched at 60 stations from 1963 to 1980 and from over 160,000 observations made by the Global Atmospheric Sampling Program on 4417 commercial airliner flights from 1975 to 1979. Case study and statistical comparisons of results from these two data sets showed that they are compatible and can be combined. Several examples of analyses that can be made by using the tabulated data are given and discussed.

Jasperson, W. H.↗

On modeling dilution jet flowfields

This paper compares temperature field measurements from selected experiments on a single row, and opposed rows, of jets injected into a ducted crossflow with profiles calculated using an empirical model based on assumed vertical profile similarity and superposition, and distributions calculated with a 3-D elliptic code using a standard K-E turbulence model. The empirical model predictions are very good within the range of the generating experiments, and the numerical model results, although exhibiting too little mixing, correctly describe the effects of the principal flow and geometric variables.

Holdeman, J. D.↗

Modeling of dilution jet flowfields

The present paper will compare temperature field measurements from selected cases in these investigations with distributions calculated with an empirical model based on assumed vertical profile similarity and superposition and with a 3-D elliptic code using a standard K-E turbulence model. The results will show the capability (or lack thereof) of the models to predict the effects of the principle flow and geometric variables.

Holdeman, J. D.↗

Tabulations of ambient ozone data obtained by GASP (Global Air Sampling Program) airliners, March 1975 to July 1979

Tabulations are given of GASP ambient ozone mean, standard deviation, median, 84th percentile, and 98th percentile values, by month, flight level, and geographical region. These data are tabulated to conform to the temporal and spatial resolution required by FAA Advisory Circular 120-38 (monthly by 2000 ft in altitude by 5 deg in latitude) for climatological data used to show compliance with cabin ozone regulations. In addition seasonal x 10 deg latitude tabulations are included which are directly comparable to and supersede the interim GASP ambient ozone tabulations given in appendix B of FAA-EE-80-43 (NASA TM-81528). Selected probability variations are highlighted to illustrate the spatial and temporal variability of ambient ozone and to compare results from the coarse and fine grid analyses.

Jasperson, W. H.↗

On modeling dilution jet flowfields

This paper compares temperature field measurements from selected experiments on a single row, and opposed rows, of jets injected into a ducted crossflow with profiles calculated using an empirical model based on assumed vertical profile similarity and superposition, and distributions calculated with a 3-D elliptic code using a standard K-E turbulence model. The empirical model predictions are very good within the range of the generating experiments, and the numerical model resultings, although exhibiting too little mixing, correctly describe the effects of the principal flow and geometric variables.

Holdeman, J. D.↗

Experiments in dilution jet mixing

Experimental results are given on the mixing of a single row of jets with an isothermal mainstream in a straight duct, to include flow and geometric variations typical of combustion chambers in gas turbine engines. The principal conclusions reached from these experiments were: at constant momentum ratio, variations in density ratio have only a second-order effect on the profiles; a first-order approximation to the mixing of jets with a variable temperature mainstream can be obtained by superimposing the jets-in-an isothermal-crossflow and mainstream profiles; flow area convergence, especially injection-wall convergence, significantly improves the mixing; for opposed rows of jets, with the orifice centerlines in-line, the optimum ratio of orifice spacing to duct height is one half of the optimum value for single side injection at the same momentum ratio; and for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single side injection at the same momentum ratio.

Holdeman, J. D.↗

Perspectives on the mixing of a row of jets with a confined crossflow

An interactive computer code, written for a microcomputer, is presented which displays 2-D and 3-D oblique plots of the temperature distribution downstream of jets mixing with a confined crossflow, for either single-side or opposed jet injection. Temperature profiles calculated with this routine are presented to show the effects of flow and geometric variables on the mixing. Examples are shown to illustrate the different perspectives on the mixing available by exercising various view options. In addition, the program is used to calculate profiles for opposed rows of jets with their centerlines in-line, by assuming that the confining effect of an opposite wall is equivalent to that of a plane of symmetry between opposed jets.

Holdeman, J. D.↗

Experiments in dilution jet mixing

Experimental results are presented on the mixing of a single row of jets with an isothermal mainstream in a straight duct, with flow and geometric variations typical of combustion chambers in gas turbine engines included. It is found that at a constant momentum ratio, variations in the density ratio have only a second-order effect on the profiles. A first-order approximation to the mixing of jets with a variable temperature mainstream can, it is found, be obtained by superimposing the jets-in-an-isothermal-crossflow and mainstream profiles. Another finding is that the flow area convergence, especially injection-wall convergence, significantly improves the mixing. For opposed rows of jets with the orifice cone centerlines in-line, the optimum ratio of orifice spacing to duct height is determined to be 1/2 of the optimum value for single injection at the same momentum ratio. For opposed rows of jets with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is found to be twice the optimum value for single side injection at the same momentum ratio.

Holdeman, J. D.↗

Dilution Zone Mixing

Studies to characterize dilution zone mixing; experiments on the effects of free-stream turbulence on a jet in crossflow; and the development of an interactive computer code for the analysis of the mixing of jets with a confined crossflow are reviewed.

Holdeman, J. D.↗

Cloud encounter statistics in the 28.5-43.5 KFT altitude region from four years of GASP observations

The results of an analysis of cloud encounter measurements taken at aircraft flight altitudes as part of the Global Atmospheric Sampling Program are summarized. The results can be used in estimating the probability of cloud encounter and in assessing the economic feasibility of laminar flow control aircraft along particular routes. The data presented clearly show the tropical circulation and its seasonal migration; characteristics of the mid-latitude regime, such as the large-scale traveling cyclones in the winter and increased convective activity in the summer, can be isolated in the data. The cloud encounter statistics are shown to be consistent with the mid-latitude cyclone model. A model for TIC (time-in-clouds), a cloud encounter statistic, is presented for several common airline routes.

Jasperson, W. H.↗

Dilution zone mixing studies

The objectives and status of a project to investigate various aspects of the jet in a confined cross flow problem are outlined. The experiments performed thus far dealt primarily with a single row of jets mixing into an isothermal flow in a constant cross section duct. Variations in the mixing were observed as a function of jet to mainstream momentum ratio, orifice size, and spacing. The current experiments examine perturbations of this problem characteristic to gas turbine combustion chambers, namely: flow area convergence, nonisothermal mainstream flow, and opposed in line and staggered injection. An empirical model was developed to describe the observed temperature distributions. The current interactive code provides a 3-D pictorial representation of the temperature, as given by these correlations, for any user specified downstream location, flow, and orifice parameters.

Holdeman, J. D.↗

Cloud-encounter and particle-concentration variabilities from GASP data

Summary statistics, tabulations, and variability studies are presented for cloud encounter and particle concentration data taken as part of the NASA global atmospheric sampling program. Cloud encounter was experienced in about 15 percent of the data samples; however, the percentage varies with season, latitude, and altitude (particularly distance from the tropopause). In agreement with classical storm models, the data show more clouds in the upper troposphere in anticyclones than in cyclones. The concentration of particles with a diameter greater than 3 micron also varies with time and location, depending primarily on the horizontal extent of cloudiness. Some examples of the application of the statistical data to the estimation of the frequency of cloud encounter and laminar flow loss to be expected on long range airline routes are also presented.

Nastrom, G. D.↗

Ozone contamination in aircraft cabins: Results from GASP data and analyses

The global atmospheric sampling program pertaining to the problem of ozone contamination in commercial airplane cabins is described. Specifically, analyses of GASP data have: confirmed the occurrence of high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; defined ambient ozone climatology at commercial airplane cruise altitudes, including tabulation of encounter frequency data which were not available before GASP; and outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data, and verified these procedures against cabin measurements.

Holdeman, J. D.↗

Ozone contamination in aircraft cabins - Results from GASP data and analyses

The paper reviews results from the NASA Global Atmospheric Sampling Program (GASP) pertaining to the problem of ozone contamination in commercial aircraft cabins. Specifically, analyses of GASP data have (1) confirmed the high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; (2) defined ambient ozone climatology at commercial aircraft cruise altitudes, including tabulation of encounter frequency data; and (3) outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data and verified these procedures against cabin measurements.

Holdeman, J. D.↗

Cloud encounter and particle density variabilities from GASP data

Summary statistics and variability studies are presented for cloud encounter and particle number density data as part of the NASA Global Atmospheric Sampling Program (GASP) aboard commercial Boeing 747 airliners. On the average, cloud encounter is shown on about 15% of the 52,164 data samples available; this value varies with season, latitude, synoptic weather situation, and distance from the tropopause. The number density of particles (diameter greater than 3 microns) also varies with time and location, and depends on the horizontal extent of cloudiness.

Nastrom, G. D.↗

Measurements of cabin and ambient ozone on B747 airplanes

In response to recent concerns over possibly high ozone levels in the cabins of aircraft flying in the stratosphere, simultaneous measurements of the cabin and ambient ozone levels have been made as part of the NASA Global Atmospheric Sampling Program. Examples of the data taken on commercially operated Boeing 747-100 and 747SP airplanes are given for selected flights, together with summary statistics of over 5600 observations. Cabin ozone levels vary with the ambient level and, for unmodified aircraft, are higher on the 747SP than on the 747-100. Modifications to the ventilation system of the 747SP reduced cabin ozone levels by varying amounts up to a factor of 14.

Nastrom, G. D.↗