Engineering PapersSearch

Engineering topics

Hoekstra, R.

Publications and source records attributed to Hoekstra, R..

Chandra Observations of Comet 2P/Encke 2003: First Detection of a Collisionally Thin, Fast Solar Wind Charge Exchange System

We report the results of 15 hr of Chandra observations of comet 2P/Encke 2003 on November 24. X-ray emission from comet Encke was resolved on scales of 500-40,000 km, with unusual morphology due to the presence of a low-density, collisionally thin (to charge exchange) coma. A light curve with peak-to-peak amplitude of 20% consistent with a nucleus rotational period of 11.1 hr was found, further evidence for a collisionally thin coma. We confirm emission lines due to oxygen and neon in the 800-1000 eV range but find very unusual oxygen and carbon line ratios in the 200-700 eV range, evidence for low-density, high effective temperature solar wind composition. We compare the X-ray spectral observation results to contemporaneous measurements of the coma and solar wind made by other means and find good evidence for the dominance of a postshock bubble of expanding solar wind plasma, moving at 600 km/s with charge state composition between that of the "fast" and "slow" solar winds.

Lisse, C. M.

GOME Calibration and Validation Using Backscatter UV Techniques

GOME radiance, irradiance, and ozone products were validated by NASA Goddard Space Flight Center through three tasks which included, pre-launch calibration comparisons with SBUV and TOMS radiometric standards, validation of GOME Level-1 irradiance and radiance and Level 2 total ozone data products using SBUV/2 and TOMS algorithms and data, and studies of GOME data using the Goddard radiative transfer code. The prelaunch calibration using the NASA large aperture integrating sphere was checked against that provided by TPD. Agreement in the calibration constants, derived in air, between the Goddard and TPD system were better than 3%. Validation of Level-1 irradiance data included comparison of GOME and SSBUV and the UARS solar irradiances measurements. Large wavelength dependent differences, as high as 10%, were noted between GOME and the US instruments. This discrepancy has now been attributed to radiometric sensitivity changes experienced by GOME when operating in a vacuum. GOME Earth radiance data were then compared to the NOAA-14 SBUV/2 radiances. These results show that between 340 and 400 nm the differences in GOME and SBUV/2 data are less than 5% with some wavelength dependence. At wavelengths shorter than 300 nm, differences are of the order of 10% or more where the GOME radiances are larger. To test GOME DOAS retrieved total ozone values, these values were compared with ozone amounts retrieved using GOME radiances in the TOMS version-7 algorithm. The differences showed a solar zenith angle dependence ranging from 0 to 10% where the TOMS algorithm values were higher. GOME radiances below 300 nm were further validated by selecting radiances at wavelengths normally used by SBUV and processing them through the SBUV ozone profile algorithm and then compared to climatological values. The GOME ozone profiles ranged from 10-30% lower over altitude compared to climatological values. This is consistent with the offsets detected in the SBUV/2 radiance comparisons at wavelengths shorter than 300 nm.

Hilsenrath, E.

The mid-ultraviolet spectrum of Epsilon Aurigae

An LTE synthetic spectrum with Te = 7800 K and log g = 1 has been computed for the 2455-to-3230 A range of Epsilon Aurigae (F0 1a). This has been compared with the spectra observed with 0.2 A resolution with the IUE experiment and with 0.1 A resolution with the BUSS experiment. As a consequence of this comparison, identifications and abundance values have been obtained. Ions definitely present include Mg I, Mg II, Al I, Al II, Si I, Ca II, Ti II, V II, Cr II, Mn II, Fe I, Fe II, Co II, Ni I, Ni II, Zr II. Ions which are possibly present include Ti III, Mn I, Fe III, Nb II, Mo I. The abundances are nearly 10 times the solar values for the iron group, with the exception of Fe, which has solar abundance. The abundances of the other elements are solar.

Castelli, F.

MAGELLAN: High resolution spectroscopy at FUV and EUV wavelengths

The aim of ESA's MAGELLAN mission is to provide high resolution spectra of celestial sources down to sixteenth magnitude over the extreme ultraviolet wavelength range (between 50 and 140 nm). This range extends from studies of interstellar matter in the disc and halo of this and other galaxies, to stellar envelopes, hot and evolved stars, clusters, intergalactic matter, nuclei of galaxies, quasars, and, finally, planets and satellites. The instrument has a nonconventional optical design using only one reflecting surface; a high groove density concave grating collects the star light, diffracts it and focuses its spectrum into a bidimensional windowless detector operated in a photon counting mode. The slitless configuration provides the spectra of all the sources (point like and extended) in the field of view of the grating. This field of view is limited by a grid collimator to reduce the diffuse background, the stray light and the probability of overlapping spectra in crowded fields.

Grewing, M.

Balloon-borne ultraviolet stellar spectrograph. I - Instrumentation and observation. II - Highlights of first observational results

A dual star-tracking system and a system including a telescope, an echelle spectrograph, and a SEC vidicon are the chief components of the Balloon-borne Ultraviolet Stellar Spectrograph (BUSS), which has flown four successful missions. The BUSS missions have yielded 81 spectra for 56 stars, recorded with a resolution of 0.1 A in the wavelength range from 2200 to 3400 A. BUSS observations include: profiles of Mg II lines indicating considerable mass flow in early-type supergiants; Mg II features suggesting a cool expanding outer shell above a hotter chromosphere; emission features in Zeta Tau (a shell star) indicating infalling material; and emission features of the Be star Phi Per suggesting mass outflow.

Kondo, Y.