Engineering Papers⌕ Search

Engineering topics

Hoarty, D. J.

Publications and source records attributed to Hoarty, D. J..

Radiation burnthrough measurements to infer opacity at conditions close to the solar radiative zone–convective zone boundary

Recent measurements at the Sandia National Laboratory of the x-ray transmission of iron plasma have inferred opacities much higher than predicted by theory, which casts doubt on modeling of iron x-ray radiative opacity at conditions close to the solar convective zone-radiative zone boundary. An increased radiative opacity of the solar mixture, in particular iron, is a possible explanation for the disagreement in the position of the solar convection zone-radiative zone boundary as measured by helioseismology and predicted by modeling using the most recent photosphere analysis of the elemental composition. In this report we present data from radiation burnthrough experiments, which do not support a large increase in the opacity of iron at conditions close to the base of the solar convection zone and provide a constraint on the possible values of both the mean opacity and the opacity in the x-ray range of the Sandia experiments. The data agree with opacity values from current state-of-the-art opacity modeling using the CASSANDRA opacity code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying electron temperature distributions from time-integrated x-ray emission spectra

K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. Here we present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of $1310^{+90}_{-70}$ eV with significant contributions from temperatures down to 200 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

X-ray-line coincidence photopumping in a potassium-chlorine mixed plasma

Exploiting the multiple long pulse capability and suite of x-ray diagnostics of the Orion laser, we have set out to explore line coincidence photopuming—the enhancement in population of an atomic level brought on by resonant absorption of x rays from a different emitting ion. Unlike previous work, the two ions are in the same plasma and so the experiment is an x-ray analog of the well-known Bowen resonance fluorescence mechanism that operates in astrophysical situations in the optical region. Herein, our measurements have shown enhanced fluorescence in a chlorine plasma, attributable to line coincident photopumping from co-mixed potassium ions. To detect this relatively low signal-to-noise phenomenon, the data from multiple shots are combined, and the statistical method of bootstrapping is used to assign a confidence value to the measured enhancement, resulting in an estimate of the enhancement of 39 ± 18 16 % compared to the null case, where no pumping occurs. The experimental results have been compared to coupled radiation-transport and radiation hydrodynamics simulations using the CRETIN code together with the NYM radiation hydrodynamics model and agreement has been found, with the simulations also predicting modest enhancement.

74 ATOMIC AND MOLECULAR PHYSICS↗