Engineering Papers⌕ Search

Engineering topics

Hoang, D.

Publications and source records attributed to Hoang, D..

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A D$_2$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2–3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIRVSS Aboard CLPS

NASA initiated the Commercial Lunar Payload Services (CLPS) program for flights to the lunar surface. Astrobotic was awarded a NASA contract to accommodate NASA payloads onto their Peregrine lander Astrobotic Mission One (ABM-1). ABM-1 is scheduled to land near Lacus Mortis, 44°N 25°E, in 2021. The Near-InfraRed Volatile Spectrometer System (NIRVSS) has evolved over time and was chosen as a NASA payload for ABM-1 and the flight model is scheduled to be delivered to Astrobotic at the end of March 2020.

Roush, T.L.↗

Variable Precision Computing

This report summarizes the activities and major accomplishments of the Variable Precision Computing Strategic Initiative project. The overarching goal of this project was to initiate and promote a new paradigm in High Performance Computing (HPC) that would fundamentally change how we represent and make use of representations of real numbers in finite precision and that would establish Lawrence Livermore National Laboratory (LLNL) as a leader in precision-related research for HPC. We pursued three integrated and concurrent research thrusts: new, more dynamic data representations to address data motion and capacity limitations; improved mixed precision algorithms to accelerate computation and to leverage new hardware; and new tools to help developers reason about precision and to automate code transformations. Within these thrust areas, we made significant advances in the use of compressed array data types in numerical calculations, in the theoretical justification, in improved performance, and in the prospects of hardware implementation; in the development of metrics to significantly reduce the storage needs of molecular dynamics simulations; in the development and analysis of efficient mixed-precision algorithms for time-dependent partial differential equations and for orthogonal factorization; and in the capability of tools that can analyze sensitivity of computed results to choices in precision and that can make automated code transformations based on such analysis. We established that there are definite opportunities to realize significant improvements in HPC above and beyond the 2x limits of traditional mixed precision using the technologies we have developed. The project produced numerous papers, presentations, and posters in important venues as well as open-source software contributions to the community, and many of the new capabilities have initiated or are being leveraged in ongoing projects.

97 MATHEMATICS AND COMPUTING↗