Engineering topics
Hines, J. Wesley
Publications and source records attributed to Hines, J. Wesley.
A New Proposal Generalized Predictive Control Algorithm With Polynomial Reference Tracking Applied for Sodium Fast Reactors
This paper proposes a generalized predictive control (GPC) with constraints and orthonormal Laguerre functions using the simplified model of the primary system (reactor core and intermediate heat exchanger (IHX)) of a prototypical sodium fast reactor (SFR). This paper develops a multiple-input multiple-output (MIMO) GPC with input constraints able to track polynomial references of any degree applied in coolant temperature difference across the core and fractional power. The manipulated variables of the GPC-SFR are the reactivity and the sodium flow rate of the primary and secondary pipes. Moreover, orthonormal Laguerre functions and step down condition number techniques were also applied to avoid the numerical ill-conditioning issue in quadratic programming of large systems. Thus, a GPC type-2 was designed to control fractional power, coolant temperature difference across the core and sodium tank temperature of the SFR primary system when temperature references change according to a linear ramp after reaching their steady-state operation, sustaining 100% power operation on the reactor. In order to analyze the load tracking capability of the GPC-SFR type-2, the load following from 100% fractional power (FP) to 60% FP at 0.8% FP/min rate is simulated. Constraints on the rate of coolant temperature difference across the core and reactivity were applied for the design safety. For comparison criteria, this paper compares the GPC-SFR type-2 with the GPC-SFR type-1, i.e., standard model predictive control (MPC), to verify the viability and superior performance of the proposal regarding: (a) ramp-tracking capability of temperature and load; (b) the rejections of a reactivity disturbance of -1 cent and a secondary sodium inlet temperature disturbance of +10°F; and (c) a simulation with uncertainty in reactor design. The simulations show that the GPC-SFR type-2 overcome the GPC-SFR type-1 robustness and performance.
Gradient-Informed Design Optimization of Select Nuclear Systems
In this work, we present a gradient-informed design optimization of nuclear reactor core components based on neutronics objectives with both continuous and discrete materials. The main argument in favor of using gradient-informed design optimization is that it scales well with increasing dimensionality of the design space. First, a challenge problem with 121 free parameters is solved with a gradient-informed method and then with a genetic algorithm. Then, a challenge problem to optimize the flux profile of a simplified assembly with eight axial zones is solved. Both challenge problems are solved using directly calculated derivatives from Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) in the SCALE package. Furthermore, we demonstrate how a discrete optimization problem—selection of materials for 121 voxels—can be lifted into a continuous problem with mixed materials. In the continuous space, adjoint-based gradients are well-defined, and gradient descent is applicable. Then, a forcing function is introduced that with the selection of an appropriately sized hyperparameter can be used to guide the optimized continuous solution back into a discrete solution. This paper presents an account of the challenges that were faced when applying a gradient-informed optimization algorithm using a Monte Carlo calculation to estimate the gradient information and compares a gradient descent optimization method to a genetic algorithm optimization of the same geometry. Overall, this work demonstrates the potential use of adjoint-based gradient calculations in design optimization of nuclear systems.
Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182
Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)
Improving the cross correlation method of indirect flow measurement by water injection and modeling - 245
This paper presents a technique to improve the Cross Correlation Function (CCF) method for indirect flow measurement. Unlike other methods, the CCF method does not need a specific instrument or tool for flow measurements. Instead, the delay time between two sensors can be derived by applying the CCF. A water flow loop was constructed to investigate the CCF method for flow measurement. Because the inherent process temperature variations were small when compared to significant amounts of measurement and process noise, inaccurate flow measurements were obtained. The performance of the CCF method could be improved by increasing the system signal-to-noise ratio, which is the process noise divided by the measurement noise. For this reason, a periodic injection of different temperature water was used to increase the process temperature variation. The results were favorable. However, several design variables needed to be selected. To assist, a CFD simulation was utilized to optimize the distance between sensors and injection point, the rate of injection flow, and other related variables. The results show that CCF optimization of these variables produces better flow measurement performance over a range of flow velocities. (authors)
Behavior-based approach to misuse detection of a simulated SCADA system - 339
This paper presents the initial findings in applying a behavior-based approach for detection of unauthorized activities in a simulated Supervisory Control and Data Acquisition (SCADA) system. Misuse detection of this type utilizes fault-free system telemetry to develop empirical models that learn normal system behavior. Future monitored telemetry sources that show statistically significant deviations from this learned behavior may indicate an attack or other unwanted actions. The experimental test bed consists of a set of Linux based enterprise servers that were isolated from a larger university research cluster. All servers are connected to a private network and simulate several components and tasks seen in a typical SCADA system. Telemetry sources included kernel statistics, resource usages and internal system hardware measurements. For this study, the Auto Associative Kernel Regression (AAKR) and Auto Associative Multivariate State Estimation Technique (AAMSET) are employed to develop empirical models. Prognostic efficacy of these methods for computer security used several groups of signals taken from available telemetry classes. The Sequential Probability Ratio Test (SPRT) is used along with these models for intrusion detection purposes. The different intrusion types shown include host/network discovery, DoS, brute force login, privilege escalation and malicious exfiltration actions. For this study, all intrusion types tested displayed alterations in the residuals of much of the monitored telemetry and were able to be detected in all signal groups used by both model types. The methods presented can be extended and implemented to industries besides nuclear that use SCADA or business-critical networks. (authors)
In-situ Condition Monitoring of Components in Small Modular Reactors Using Process and Electrical Signature Analysis. Final report, volume 1. Development of experimental flow control loop, data analysis and plant monitoring
The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on plant parameters and the pump electrical signatures. Additionally, the reactor simulation is being used to generate normal operation data and data with instrumentation faults and process anomalies. A frequency controller was interfaced with the motor power supply in order to vary the electrical supply frequency. The experimental flow control loop was used to generate operational data under varying motor performance characteristics. Coolant leakage events were simulated by varying the bypass loop flow rate. The accuracy of motor power calculation was improved by incorporating the power factor, computed from motor current and voltage in each phase of the induction motor.- A variety of experimental runs were made for steady-state and transient pump operating conditions. Process, vibration, and electrical signatures were measured using a submersible pump with variable supply frequency. High correlation was seen between motor current and pump discharge pressure signal; similar high correlation was exhibited between pump motor power and flow rate. Wide-band analysis indicated high coherence (in the frequency domain) between motor current and vibration signals. - Wide-band operational data from a PWR were acquired from AMS Corporation and used to develop time-series models, and to estimate signal spectrum and sensor time constant. All the data were from different pressure transmitters in the system, including primary and secondary loops. These signals were pre-processed using the wavelet transform for filtering both low-frequency and high-frequency bands. This technique of signal pre-processing provides minimum distortion of the data, and results in a more optimal estimation of time constants of plant sensors using time-series modeling techniques.
Development and Validation of a Lifecycle-based Prognostics Architecture with Test Bed Validation
On-line monitoring and tracking of nuclear plant system and component degradation is being investigated as a method for improving the safety, reliability, and maintainability of aging nuclear power plants. Accurate prediction of the current degradation state of system components and structures is important for accurate estimates of their remaining useful life (RUL). The correct quantification and propagation of both the measurement uncertainty and model uncertainty is necessary for quantifying the uncertainty of the RUL prediction. This research project developed and validated methods to perform RUL estimation throughout the lifecycle of plant components. Prognostic methods should seamlessly operate from beginning of component life (BOL) to end of component life (EOL). We term this "Lifecycle Prognostics." When a component is put into use, the only information available may be past failure times of similar components used in similar conditions, and the predicted failure distribution can be estimated with reliability methods such as Weibull Analysis (Type I Prognostics). As the component operates, it begins to degrade and consume its available life. This life consumption may be a function of system stresses, and the failure distribution should be updated to account for the system operational stress levels (Type II Prognostics). When degradation becomes apparent, this information can be used to again improve the RUL estimate (Type III Prognostics). This research focused on developing prognostics algorithms for the three types of prognostics, developing uncertainty quantification methods for each of the algorithms, and, most importantly, developing a framework using Bayesian methods to transition between prognostic model types and update failure distribution estimates as new information becomes available. The developed methods were then validated on a range of accelerated degradation test beds. The ultimate goal of prognostics is to provide an accurate assessment for RUL predictions, with as little uncertainty as possible. From a reliability and maintenance standpoint, there would be improved safety by avoiding all failures. Calculated risk would decrease, saving money by avoiding unnecessary maintenance. One major bottleneck for data-driven prognostics is the availability of run-to-failure degradation data. Without enough degradation data leading to failure, prognostic models can yield RUL distributions with large uncertainty or mathematically unsound predictions. To address these issues a "Lifecycle Prognostics" method was developed to create RUL distributions from Beginning of Life (BOL) to End of Life (EOL). This employs established Type I, II, and III prognostic methods, and Bayesian transitioning between each Type. Bayesian methods, as opposed to classical frequency statistics, show how an expected value, a priori, changes with new data to form a posterior distribution. For example, when you purchase a component you have a prior belief, or estimation, of how long it will operate before failing. As you operate it, you may collect information related to its condition that will allow you to update your estimated failure time. Bayesian methods are best used when limited data are available. The use of a prior also means that information is conserved when new data are available. The weightings of the prior belief and information contained in the sampled data are dependent on the variance (uncertainty) of the prior, the variance (uncertainty) of the data, and the amount of measured data (number of samples). If the variance of the prior is small compared to the uncertainty of the data, the prior will be weighed more heavily. However, as more data are collected, the data will be weighted more heavily and will eventually swamp out the prior in calculating the posterior distribution of model parameters. Fundamentally Bayesian analysis updates a prior belief with new data to get a posterior belief. The general approach to applying the Bayesian method to lifecycle prognostics consisted of identifying the prior, which is the RUL estimate and uncertainty from the previous prognostics type, and combining it with observational data related to the newer prognostics type. The resulting lifecycle prognostics algorithm uses all available information throughout the component lifecycle.