Engineering Papers⌕ Search

Engineering topics

Hilsenrath, E.

Publications and source records attributed to Hilsenrath, E..

71 records · Page 4

Water vapor in the lower stratosphere measured from aircraft flight

Water vapor in the lower stratosphere was measured in situ by two aluminum oxide hygrometers mounted on the nose of an RB57 aircraft. Data were taken nearly continuously from January to May 1974 from an altitude of approximately 11 km to 19 km as the aircraft flew between 70 deg N and 50 deg S over the land areas in the Western Hemisphere. Pseudomeridional cross sections of water vapor and temperature are derived from the flight data and show mixing ratios predominantly between 2 and 4 micron gm/gm with an extreme range of 1 to 8 micron gm/gm. Measurement precision is estimated by comparing the simultaneously measured values from the two flight hygrometer systems. Accuracy is estimated to be about + or - 40 percent at 19 km. A height-averaged latitudinal cross section of water vapor shows symmetry of wet and dry zones.

Hilsenrath, E.↗

Nitric oxide, water vapor, and ozone in the atmosphere as measured in SITU from an aircraft

As part of the instrument evaluation plan for the NASA Global Atmospheric Sampling Program, prototype instruments were tested aboard the NASA Convair 990 during four flights in January and February of 1974. All the data were taken in maritime air between Hawaii and San Francisco and between Hawaii and 155 deg W, 35 deg N. A chemiluminescent instrument was used to measure nitric oxide. Water vapor, which was measured by using an aluminum oxide hygrometer, ranged from 5.2 micro g/g to saturation. Ozone was measured by an instrument using the ultraviolet absorption technique and ranged up to 235 ppbv. Typical temporal plots of the concentrations of the three constituents are presented. All the constituents showed considerable spatial and day-to-day variation in concentration at each altitude flown. Measurements of the three constituents were made simultaneously at various altitudes between 7.6 and 12.5 km.

Briehl, D.↗

Aircraft water vapor measurements utilizing an aluminum oxide hygrometer

A hygrometer for water vapor measurements from an aircraft was developed. An aluminum oxide hygrometer mounted in an aircraft Rosemount air temperature scoop was flown on the NASA Convair 990 and on a USAF B-57 aircraft. Water vapor measurements from the Convair 990 were conducted up to 40,000 ft with penetration into the stratosphere. Good agreement was obtained with simultaneously flown remote sounders of water vapor. During transcontinental flights the hygrometer demonstrated adequate response to measure the natural variability of water vapor near the tropopause. Rapid response was demonstrated in pursuit of the jet wake of an F-104 at 35,000 ft.

Hilsenrath, E.↗

In situ measurements of nitric oxide, water vapour and ozone from an aircraft

This paper describes flight tests of prototype instruments for the NASA global atmospheric sampling program (GASP). Three gas sampling instruments were included in the installation: (1) a chemiluminescent nitric oxide monitor; (2) an ultraviolet absorption ozone monitor; and (3) an aluminum oxide water vapor hygrometer. Results indicate the range and kind of variability in NO, H2O, and O3 that can be expected in routine tropospheric air sampling. They have also demonstrated the need for increasing instrument sensitivities, particularly in NO measurement.

Briehl, D. C.↗

Nuclear weapons tests and short-term effects on atmospheric ozone

Observations made when Nimbus 4 passed over a nuclear cloud about three hours after the bomb exploded are presented. Infrared and BUV measurements indicated that the atmospheric ozone level in the area of cloud was significantly less than in areas directly north and south of the cloud. It is noted, however, that it is not possible to state definitively that the ozone depletion was caused by nitrogen oxides released in the nuclear weapons test, and that further observations must be made to clarify the situation.

Miller, A. J.↗

Aircraft water vapor measurements utilizing an aluminum oxide hygrometer

A hygrometer for water vapor measurements from an aircraft has been developed. An aluminum oxide hygrometer mounted in an aircraft Rosemount air temperature scoop was flown on NASA and USAF aircraft. Water vapor measurements were conducted up to 40,000 feet with penetration into the stratosphere. Good agreement was obtained with simultaneously flown remote sounders of water vapor. During transcontinental flights the hygrometer demonstrated adequate response to measure the natural variability of water vapor near the tropopause. Rapid response was demonstrated in pursuit of the jet wake of an F-104 at 35,000 feet.

Hilsenrath, E.↗

High altitude aircraft water vapor measurements.

A hygrometer for water vapor measurements from an aircraft was developed. An aluminum oxide hygrometer mounted in an aircraft Rosemount air temperature scoop was flown on the NASA Convair 990 and on a USAF B-57 aircraft. Water vapor measurements from the Convair 990 were conducted up to 40,000 ft with penetration into the stratosphere. Good agreement was obtained with simultaneously flown remote sounders of water vapor. During transcontinental flights the hygrometer demonstrated adequate response to measure the natural variability of water vapor near the tropopause. Rapid response was demonstrated in pursuit of the jet wake of an F-104 at 35,000 ft.

Hilsenrath, E.↗

Meteorological applications of the Nimbus 4 temperature-humidity infrared radiometer, 6.7 micron channel data.

Midtropospheric circulation features under essentially clear sky conditions have been noted in the data of the 6.7-micron channel of the Nimbus 4 temperature-humidity infrared radiometer (THIR), while at the same time these features were undetected by the 11.5-micron channel of the same instrument. The characteristic response of the 6.7-micron channel to atmospheric water vapor emission is primarily from the 250-mb (10.5 km) to 500-mb (5.5 km) levels with a peak contribution at 350 mb (8 km). Dry and moist patterns seen in the 6.7-micron data on Feb. 21, 1971, have been integrated into a 400-mb moisture analysis over the United States. This analysis provided more detailed and timely information than was conventionally available about the advection of dry air aloft prior to development of the Mississippi Tornado of February 1971.

Allison, L. J.↗

Rocket sonde measurements of ozone in the upper atmosphere

Rocket sonde measurement of ozone content in the mesosphere and stratosphere is accomplished by an in situ determination of the ozone mixing rates as a function of altitude from approximately 65 km to 20 km. A chemiluminescent detector is used as an ozone sensor.

Hilsenrath, E.↗