NASA's Earth Science Research and Environmental Predictions

NASA Earth Science program began in the 1960s with cloud imaging satellites used for weather observations. A fleet of satellites are now in orbit to investigate the Earth Science System to uncover the connections between land, Oceans and the atmosphere. Satellite systems using an array of active and passive remote sensors are used to search for answers on how is the Earth changing and what are the consequences for life on Earth? The answer to these questions can be used for applications to serve societal needs and contribute to decision support systems for weather, hazard, and air quality predictions and mitigation of adverse effects. Partnerships with operational agencies using NASA's observational capabilities are now being explored. The system of the future will require new technology, data assimilation systems which includes data and models that will be used for forecasts that respond to user needs.

Hilsenrath, E.

The EOS Aura Mission

The Earth Observing System (EOS) Aura satellite is scheduled to launch in the second quarter of 2004. The Aura mission is designed to attack three science questions: (1) Is the ozone layer recovering as expected? (2) What are the sources and processes that control tropospheric pollutants? (3) What is the quantitative impact of constituents on climate change? Aura will answer these questions by globally measuring a comprehensive set of trace gases and aerosols at high vertical and horizontal resolution. Fig. 1 shows the Aura spacecraft and its four instruments.

Schoebert, Mark R.

Retrieval of Total Ozone Amounts from Zenith-Sky Intensities in the Ultraviolet Region

A new method to determine the total ozone column from zenith-sky intensities in the ultraviolet region has been developed for the Shuttle Solar Backscatter Ultraviolet Spectrometer (SSBUV) operating at the NASA Goddard Space Flight Center. The total ozone column amounts are derived by comparing the ratio of measured intensities from three wavelengths with the equivalent ratios calculated by a radiative transfer model. The differences between the retrieved ozone column amounts and the collocated Brewer double monochromator are within 2% for the measurement period beginning in April 2001. The methodology, as well as the influences of the ozone profiles, aerosols, surface albedo, and the solar zenith angle on the retrieved total ozone amounts will be presented.

Bojkov, B. R.

Validation of SCIAMACHY and TOMS UV Radiances Using Ground and Space Observations

Verification of a stratospheric ozone recovery remains a high priority for environmental research and policy definition. Models predict an ozone recovery at a much lower rate than the measured depletion rate observed to date. Therefore improved precision of the satellite and ground ozone observing systems are required over the long term to verify its recovery. We show that validation of satellite radiances from space and from the ground can be a very effective means for correcting long term drifts of backscatter type satellite measurements and can be used to cross calibrate all B W instruments in orbit (TOMS, SBW/2, GOME, SCIAMACHY, OM, GOME-2, OMPS). This method bypasses the retrieval algorithms used for both satellite and ground based measurements that are normally used to validate and correct the satellite data. Radiance comparisons employ forward models and are inherently more accurate than inverse (retrieval) algorithms. This approach however requires well calibrated instruments and an accurate radiative transfer model that accounts for aerosols. TOMS and SCIAMACHY calibrations are checked to demonstrate this method and to demonstrate applicability for long term trends.

Hilsenrath, E.

Validation of SCIAMACHY Radiances and Ozone Products Using Ground and Space Observations

Validation of SCIAMACHY data products are is key element for the detecting a stratospheric ozone recovery, which is a high priority for environmental research and environmental policy. Models predict an ozone recovery at a much lower rate than the measured depletion rate observed to date. Therefore improved precision of the satellite and ground ozone observing systems are required over the long term to verify its recovery. We show that validation of satellite radiances from space and from the ground can be an effective means for correcting long term drifts of backscatter type satellite measurements such as SCIAMACHY and can be used to cross calibrate all BUV instruments in orbit (TOMS, SBUV/2, GOME, OMI, GOME-2, OMPS). This method bypasses the retrieval algorithms used for both satellite and ground based measurements that are normally used to validate and correct the satellite data. This approach however requires well calibrated instruments and an accurate radiative transfer model that accounts for aerosols. In addition to comparing radiances, validation of SCIAMACHY ozone products will conducted by comparing total and profile ozone with TOMS and SBUV/2.

Hilsenrath, E.

Can One Satellite Data Set Validation Another? Validation of Envisat SCIAMACHY Data by Comparisons with NOAA-16 SBUV/2 and ERS-2 GOME

Validation of satellite data remains a high priority for the construction of climate data sets. Traditionally ground based measurements have provided the primary comparison data for validation. For some atmospheric parameters such as ozone, a thoroughly validated satellite data record can be used to validate a new instrument s data product in addition to using ground based data. Comparing validated data with new satellite data has several advantages; availability of much more data, which will improve precision, larger geographical coverage, and the footprints are closer in size, which removes uncertainty due to different observed atmospheric volumes. To demonstrate the applicability and some limitations of this technique, observations from the newly launched SCIAMACHY instrument were compared with the NOM-16 SBW/2 and ERS-2 GOME instruments. The SBW/2 data had all ready undergone validation by comparing to the total ozone ground network. Overall the SCIAMACHY data were found to low by 3% with respect to satellite data and 1% low with respect to ground station data. There appears to be seasonal and or solar zenith angle dependences in the comparisons with SBW/2 where differences increase with higher solar zenith angles. It is known that accuracies in both satellite and ground based total ozone algorithms decrease at high solar zenith angles. There is a strong need for more accurate measurement from and the ground under these conditions. At the present time SCIAMACHY data are limited and longer data set with more coverage in both hemispheres is needed to unravel the cause of these differences.

Hilsenrath, E.

EOS-Aura's Ozone Monitoring Instrument (OMI): Validation Requirements

OMI is an advanced hyperspectral instrument that measures backscattered radiation in the UV and visible. It will be flown as part of the EOS Aura mission and provide data on atmospheric chemistry that is highly synergistic with other Aura instruments HIRDLS, MLS, and TES. OMI is designed to measure total ozone, aerosols, cloud information, and UV irradiances, continuing the TOMS series of global mapped products but with higher spatial resolution. In addition its hyperspectral capability enables measurements of trace gases such as SO2, NO2, HCHO, BrO, and OClO. A plan for validation of the various OM1 products is now being formulated. Validation of the total column and UVB products will rely heavily on existing networks of instruments, like NDSC. NASA and its European partners are planning aircraft missions for the validation of Aura instruments. New instruments and techniques (DOAS systems for example) will need to be developed, both ground and aircraft based. Lidar systems are needed for validation of the vertical distributions of ozone, aerosols, NO2 and possibly SO2. The validation emphasis will be on the retrieval of these products under polluted conditions. This is challenging because they often depend on the tropospheric profiles of the product in question, and because of large spatial variations in the troposphere. Most existing ground stations are located in, and equipped for, pristine environments. This is also true for almost all NDSC stations. OMI validation will need ground based sites in polluted environments and specially developed instruments, complementing the existing instrumentation.

Brinksma, E. J.

Validation of Envisat Ozone Data Products using Satellite and Ground Based Data

The Envisat chemistry instruments provide an opportunity to continue the ozone data sets produced by TOMS, SBUV, HALOE, and SAGE. These data sets have already been extensively validated and are assured to be of high accuracy. Continuity and consistency of data sets among the various satellite instruments as well as ground networks is essential for detecting an ozone recovery and climate change. Our objective, as part of the Envisat CaWal program, is to validate SCIAMACHY, MIPAS, and GOMOS ozone products using these heritage instruments. In addition we plan to validate SCIAMACHY Level 1 radiance using heritage satellite data and ground observations using a radiative transfer model. Ground based data included US ozonesonde profiles and a double monochromator Brewer instrument located at Goddard Space Flight Center. To date we have tested our intercomparisons algorithms using available Envisat data compared with SBW/2 and the ground based observations. We analyzed the comparisons with respect to ozone amounts and latitude and found the differences that were expected based on the initial release of Envisat data, which had known deficiencies. We will present our latest results based on the most current release of Envisat ozone data products.

Hilsenrath, E.

Calibration of TOMS Radiances From Ground Observations

Verification of a stratospheric ozone recovery remains a high priority for environmental research and policy definition. Models predict an ozone recovery at a much lower rate than the measured depletion rate observed to date. Therefore improved precision of the satellite and ground ozone observing systems are required over the long term to verify its recovery. We show that validation of radiances from the ground can be a very effective means for correcting long term drifts of backscatter type satellite measurements and can be used to cross calibrate all BUV instruments in orbit (TOMS, SBUV/2, GOME, SCIAMACHY, OMI, GOME-2, OMPS). This method bypasses the retrieval algorithms used to derive ozone products from both satellite and ground based measurements that are normally used to validate the satellite data. Radiance comparisons employ forward models, but they are inherently more accurate than the retrieval This method employs very accurate comparisons between ground based zenith sicy radiances and satellite nadir radiances and employs two well established capabilities at the Goddard Space Flight Center, 1) the SSBUV calibration facilities and 2) the radiative transfer codes used for the TOMS and SBUV/2 algorithms and their subsequent refinements. The zenith sky observations are made by the SSBUV where its calibration is maintained to a high degree of accuracy and precision. Radiative transfer calculations show that ground based zenith sky and satellite nadir backscatter ultraviolet comparisons can be made very accurately under certain viewing conditions. Initial ground observations taken from Goddard Space Flight Center compared with radiative transfer calculations has indicated the feasibility of this method. The effect of aerosols and varying ozone amounts are considered in the model simulations and the theoretical comparisons. The radiative transfer simulations show that the ground and satellite radiance comparisons can be made with an uncertainty of less than l\% without the knowledge of the amount ozone viewed by either instrument on ground or in space. algorithms.

Bojkov, B. R.

Description and Sensitivity Analysis of the SOLSE/LORE-2 and SAGE III Limb Scattering Ozone Retrieval Algorithms

The SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) instruments are scheduled for reflight on Space Shuttle flight STS-107 in July 2002. In addition, the SAGE III (Stratospheric Aerosol and Gas Experiment) instrument will begin to make limb scattering measurements during Spring 2002. The optimal estimation technique is used to analyze visible and ultraviolet limb scattered radiances and produce a retrieved ozone profile. The algorithm used to analyze data from the initial flight of the SOLSE/LORE instruments (on Space Shuttle flight STS-87 in November 1997) forms the basis of the current algorithms, with expansion to take advantage of the increased multispectral information provided by SOLSE/LORE-2 and SAGE III. We also present detailed sensitivity analysis for these ozone retrieval algorithms. The primary source of ozone retrieval error is tangent height misregistration (i.e., instrument pointing error), which is relevant throughout the altitude range of interest, and can produce retrieval errors on the order of 10-20 percent due to a tangent height registration error of 0.5 km at the tangent point. Other significant sources of error are sensitivity to stratospheric aerosol and sensitivity to error in the a priori ozone estimate (given assumed instrument signal-to-noise = 200). These can produce errors up to 10 percent for the ozone retrieval at altitudes less than 20 km, but produce little error above that level.

Loughman, R.

Calibration of the Shuttle Ozone Limb Sounding Experiment (SOLSE) and the Limb Ozone Retrieval Experiment (LORE)

The calibration and characterization of two new instruments designed to retrieve ozone profiles into the lower stratosphere will be presented. These instruments will fly as a single payload on the Space Shuttle Columbia currently scheduled to lift off July 11, 2002. The purpose of SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) is to provide a thorough test of the limb ozone retrieval technique, which is being employed on several satellite instruments currently deployed or planned for deployment in the near future. OSIRIS (Optical Spectrograph and Infrared Imager System) and SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography) are already in orbit, while OMPS (the Ozone Mapping and Profiler Suite) is planned as the primary US ozone monitoring instrument in the next decade.. SOLSE is a Czerny-Turner spectrograph utilizing a 1k x 1k cooled CCD at the focal plane and covering the spectral range of 310-380 nm in the ultraviolet and 535-865 nm in the visible to near infrared. LORE is a 5 channel filter radiometer with center band wavelengths of 322, 350, 603, 675, and 1000 nm. The focus of this paper will be on measurements of the SOLSE spectrograph performance in the limb-viewing configuration including stray light rejection, spatial and spectral resolution and absolute radiometric response.

Janz, S. J.

Aura Science and Validation

The EOS-Aura Mission is designed to answer three basic questions concerning the Earth's atmosphere: 1) Is ozone recovering as predicted, 2) is air quality getting worse, and 3) how is climate changing? Aura's four instruments work synergistically and are dedicated to answering these questions. These questions relate to NASA Earth Science Enterprise's overall strategic questions, which seek to understand the consequences of climate change for human civilization and determine if these changes can be predicted. NASA supports an ongoing research and analysis program, which is conducted independently and in support of satellite missions. The research program conducts several on-going field campaigns employing aircraft, balloons, and ground based systems. These campaigns have focused on exploring processes in the tropics, high latitudes, and continental outflow to explain the chemistry and transport in the troposphere and stratosphere and how these regions interact. NASA is now studying how the Aura mission and requirements of the research and analysis program might be merged to achieve its strategic goals related to global atmospheric chemistry changes. In addition, NASA field campaign resources will be folded into Aura's validation requirements. Aura validation requires correlative measurements throughout the troposphere and stratosphere under a range of observing and geophysical conditions. Because of the recent launches of Envisat and other smaller international chemistry satellites, the NASA program plans to collaborate with European space agencies in developing a series of campaigns that will provide continuity between those satellites missions and Aura.

Hilsenrath, E.

Science Objectives of EOS-Aura's Ozone Monitoring Instrument (OMI)

OMI is a UV/VIS nadir solar backscatter spectrograph, which provides near global coverage in one day with a spatial resolution of 13 x 24 sq km. OMI is a new instrument, with a heritage from the European satellite instruments GOME, GOMOS and SCIAMACHY. OMI's unique capabilities for measuring important trace gases with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will measure solar irradiance and Earth radiances in the wavelength range of 270 to 500 nm with spectral resolution of about 0.5 nm and a spectral sampling of about 2-3 per FWHM. From these observations, total columns of O3, NO2, BrO and SO2 will be derived from the back-scattered solar radiance using differential absorption spectroscopy (DOAS). The TOMS total ozone record will also be continued by employing the well established TOMS algorithm. Because of the high accuracy and spatial resolution of the measurements, a good estimate of tropospheric amounts of ozone and NO2 are expected. Ozone profiles will be derived using the optimal estimation method. The spectral aerosol optical depth will be determined from measurements between 340 and 500 nm. This will provide information on aerosol concentration, aerosol size distribution and aerosol type. This wavelength range makes it possible to retrieve aerosol information over both land and sea. OMI observations will also allow retrievals of cloud coverage and cloud heights. From these products, the UV-B flux at the surface can then be derived with high spatial resolution.

Levelt, P. F.

The EOS Aura Mission

The EOS Aura Mission is designed to make comprehensive chemical measurements of the troposphere and stratosphere. In addition the mission will make measurements of important climate variables such as aerosols, and upper tropospheric water vapor and ozone. Aura will launch in late 2003 and will fly 15 minutes behind EOS Aqua in a polar sun synchronous ascending node orbit with a 1:30 pm equator crossing time.

Schoeberl, Mark R.

Science Requirements Document for OMI-EOS

A Dutch-Finnish scientific and industrial consortium is supplying the Ozone Monitoring Instrument (OMI) for Earth Observing System-Aura (EOS-Aura). EOS-Aura is the next NASA mission to study the Earth's atmosphere extensively, and successor to the highly successful UARS (Upper Atmospheric Research Satellite) mission. The 'Science Requirements Document for OMI-EOS' presents an overview of the Aura and OMI mission objectives. It describes how OMI fits into the Aura mission and it reviews the synergy with the other instruments onboard Aura to fulfill the mission. This evolves in the Scientific Requirements for OMI (Chapter 3), stating which trace gases have to be measured with what necessary accuracy, in order for OMI to meet Aura's objectives. The most important data product of OMI, the ozone vertical column, densities shall have a better accuracy and an improved global coverage than the predecessor instruments TOMS (Total Ozone Monitoring Spectrometer) and GOME (Global Ozone Monitoring Experiment), which is a.o. achieved by a better signal to noise ratio, improved calibration and a wide field-of-view. Moreover, in order to meet its role on Aura, OMI shall measure trace gases, such as NO2, OClO, BrO, HCHO and SO2, aerosols, cloud top height and cloud coverage. Improved accuracy, better coverage, and finer ground grid than has been done in the past are goals for OMI. After the scientific requirements are defined, three sets of subordinate requirements are derived. These are: the algorithm requirements, i.e. what do the algorithms need in order to meet the scientific requirements; the instrument and calibration requirements, i.e. what has to be measured and how accurately in order to provide the quality of data necessary for deriving the data products; and the validation requirements, i.e. a strategy of how the OMI program will assure that its data products are valid in the atmosphere, at least to the required accuracy.

Levelt, P. F.

The Retrieval of Ozone Profiles from Limb Scatter Measurements: Theory

An algorithm is presented for retrieving vertical profiles of O3 concentration using measurements of UV and visible light scattered from the limb of the atmosphere. The UV measurements provide information about the O3 profile in the upper and middle stratosphere, while only visible wavelengths are capable of probing the lower stratospheric O3 profile. Sensitivity to the underlying scene reflectance is greatly reduced by normalizing measurements at a tangent height high in the atmosphere (approximately 55 km), and relating measurements taken at lower altitudes to this normalization point. To decrease the effect of scattering by thin aerosols/clouds that may be present in the field of view, these normalized measurements are then combined by pairing wavelengths with strong and weak O3 absorption. We conclude that limb scatter can be used to measure O3 between 15 km and 50 km with 2-3 km vertical resolution and better than 10% accuracy.

Flittner, D. E.

The Effect of Clouds Upon Limb Scattered Radiances and the Retrieval of Ozone Profiles Using These Radiances

The use of limb scattered radiance profiles to retrieve ozone profiles is currently being investigated. The goal is to produce ozone profiles with better vertical resolution than is available with the Backscattered Ultraviolet (BUV) technique and with much greater spatial and temporal coverage than with the solar occultation method (i.e. SAGE II). This method, which uses UV and visible light scattered from the earth's limb, has recently been proven to work for clear sky cases with data from the STS-87 flight of the Shuttle Ozone Sounding Limb Experiment/Limb Ozone Retrieval Experiment (SOLSE/LORE). As to be expected, clouds have a substantial impact upon the limb radiance (increasing the radiance as much as 80-100% is some cases). Here we use a variety of radiative transfer models and limited SOLSE/LORE data to investigate the effect of clouds upon the limb radiance at wavelengths used in the ozone retrieval (approximately 600 nm). Though the presence of clouds can greatly increase the limb radiance, they have a minimal effect upon the retrieved ozone profile, since the retrieval uses a differential absorption technique.

Flittner, D. E.