Engineering PapersSearch

Engineering topics

Heyman, J. S.

Publications and source records attributed to Heyman, J. S..

At least 37 records · Page 2

Ultrasonic characterization of plastic deformation in metals

Acoustic tone burst spectroscopy is used to examine the effect of plastic deformation on higher order elastic properties of specimens of AISI 1016, 1045, 1095 and 8620 steel rods by measuring the stress acoustic constants (SACs). The SAC is found to be influenced by prestraining, and prestrain SAC measurements on 8620 steel demonstrate similar behavior to previously measured steels even though the composition of 8620 steel is significantly different. It is suggested from bias stress measurements that the stress acoustic response of prestrained 8620 steel is sensitive to the sign of the applied stress due to the different directions is which dislocations move under tension as opposed to compression, providing an approach to nondestructive testing of residual stress in steels.

Allison, S. G.

Magnetoacoustic stress measurements in steel

Uniaxial stress effects on the low-field magnetoacoustic interaction have been studied using bulk compressional waves and Rayleigh surface waves in numerous steel samples having various impurity concentrations (Namkung et al., 1984). The results invariably showed that the initial slope of acoustic natural velocity variations, with respect to net induced magnetization parallel to the stress axis, is positive under tension and negative under compression. The results of current measurements in railroad rail steel having about 0.68 wt percent carbon content are typical for medium range carbon steels. The low-field natural velocity slope in this particular type of steel, which is almost zero when unstressed, becomes steeper with increased magnitude of stress in both directions. Hence, the nondestructive determination of the sign of residual stress in railroad wheels and rails is possible using this technique. This paper discusses the basic physical mechanism underlying the experimental observations and presents the results obtained in railroad rail steel.

Namkung, M.

Nondestructive ultrasonic measurement of bolt preload using the pulsed-phase locked-loop interferometer

Achieving accurate preload in threaded fasteners is an important and often critical problem which is encountered in nearly all sectors of government and industry. Conventional tensioning methods which rely on torque carry with them the disadvantage of requiring constant friction in the fastener in order to accurately correlate torque to preload. Since most of the applied torque typically overcomes friction rather than tensioning the fastener, small variations in friction can cause large variations in preload. An instrument called a pulsed phase locked loop interferometer, which was recently developed at NASA Langley, has found widespread use for measurement of stress as well as material properties. When used to measure bolt preload, this system detects changes in the fastener length and sound velocity which are independent of friction. The system is therefore capable of accurately establishing the correct change in bolt tension. This high resolution instrument has been used for precision measurement of preload in critical fasteners for numerous applications such as the space shuttle landing gear and helicopter main rotors.

Allison, S. G.

The effect of carbon concentration and plastic deformation on ultrasonic higher order elastic properties of steel

The behavior of higher order elastic properties, which are much more sensitive to material state than are second order properties, has been studied for steel alloys AISI 1016, 1045, 1095, and 8620 by measuring the stress derivative of the acoustic natural velocity to determine the stress acoustic constants (SAC's). Results of these tests show a 20 percent linear variation of SAC's with carbon content as well as even larger variations with prestrain (plastic deformation). The use of higher order elastic characterization permits quantitative evaluation of solids and may prove useful in studies of fatigue and fracture.

Heyman, J. S.

Energy shadowing correction of ultrasonic pulse-echo records by digital signal processing

A numerical algorithm is described that enables the correction of energy shadowing during the ultrasonic testing of bulk materials. In the conventional method, an ultrasonic transducer transmits sound waves into a material that is immersed in water so that discontinuities such as defects can be revealed when the waves are reflected and then detected and displayed graphically. Since a defect that lies behind another defect is shadowed in that it receives less energy, the conventional method has a major drawback. The algorithm normalizes the energy of the incoming wave by measuring the energy of the waves reflected off the water/air interface. The algorithm is fast and simple enough to be adopted for real time applications in industry. Images of material defects with the shadowing corrections permit more quantitative interpretation of the material state.

Kishonio, D.

Method for thermal monitoring subcutaneous tissue

A noninvasive accurate method for measuring the temperature of tissue beneath the surface of a living body is described. Ultrasonic signals are directed into beads of a material that are inserted into the tissue with a syringe. The reflected signals indicate the acoustic impedance or resonance frequency of the beads which in turn indicates the temperature of the tissue. A range of temperatures around the melting temperature of the material can be measured by this method.

Heyman, J. S.

Profiles of fatigue damage in graphite/epoxy composites from ultrasonic transmission power spectra

Early fatigue damage in non-unidirectional multi-ply graphite/epoxy composites is manifested by a distribution of cracks and disbonds through the bulk of the material. Such damage is subtle and is difficult to detect with conventional ultrasonic technology. Consequently, a new ultrasonic measurement technique called phase-insensitive tone-burst spectroscopy has been developed. The new technique eliminates problems associated with phase cancellation and pulse shape artifacts inherent to conventional broadband ultrasonic spectral measurement systems and produces clean spectral information irrespective of specimen inhomogeneity or irregularities in surface geometry. Application of the new technique to measurements of graphite/epoxy composites has yielded frequency-domain profiles that show distinct differences in ultrasonic attenuation, attenuation slope, and velocity for each specimen experiencing a different level of fatigue damage.

Cantrell, J. H., Jr.

Acoustic Tooth Cleaner

Acoustically-energized water jet aids in plaque breakdown. Acoustic Wand includes acoustic transducer 1/4 wave plate, and tapered cone. Together elements energize solution of water containing mild abrasive injected into mouth to help prevent calculous buildup.

Heyman, J. S.

Acoustic Design Improves Composite Impact Resistance

Improved tolerance of composites to impact damage achieved using acoustic response model to characterize dynamics of damage mechanism. Model based on assumption that in addition to classical mechanical properties, damage mechanism depends on acoustic properties of composite material. Use of model results in more-impact-resistant composite structure.

Heyman, J. S.

Residual stress characterization with an ultrasonic/magnetic technique

A potentially useful new technique for residual stress characterization in ferromagnetic material is described. The unique feature of this technique is the measurement of small changes in ultrasonic wave velocity by the application of external dc magnetic field in the material under various stress conditions. It was found, in steel, that the fractional change in the natural velocity Delta W/W of waves propagating along the external field direction is affected by the uniaxial stress applied in the same axis. External compression lowers the slope of the Delta W/W curve in the low field region, while external tension generally does the opposite. For most cases, the slope in this region falls below zero under external compression. The result of measurements in specimens with residual stress shows exactly the same tendency.

Namkung, M.

Error correction method and apparatus for electronic timepieces

A method and apparatus for correcting errors in an electronic digital timepiece that includes an oscillator which has a 2 in. frequency output, an n-stage frequency divider for reducing the oscillator output frequency to a time keeping frequency, and means for displaying the count of the time keeping frequency. In first and second embodiments of the invention the timepiece is synchronized with a time standard at the beginning of the period of time T. In the first embodiment of the invention the timepiece user observes E (the difference between the time standard and the timepiece time at the end of the period T) and then operates a switch to correct the time of the timepiece and to obtain a count for E. In the second embodiment of the invention, the user operates a switch at the beginning of T and at the end of T and a count for E is obtained electronically.

Davidson, J. R.

Pulsed phase locked loop strain monitor

The RF output of a voltage controlled oscillator (VCO) is periodically gated to a transducer which produces acoustic waves in a bolt. The reflected acoustic waves are converted to electrical signals by the transducer and gated to a mixer which also receives the output from the VCO and produces an output which is filtered by a low pass filter. The output of filter is a dc signal proportional to the phase difference change from a fixed phase difference between the two input signals to the mixer. This dc signal is sampled at an instant and held by circuit in response to the "P" signal. The output of the circuit is integrated and then applied to the VCO to change the frequency of the VCO such that the phase difference between the two inputs to the mixer remains at the fixed phase difference. The frequency of the VCO is a measure of the change in strain of the bolt.

Heyman, J. S.

Electronically Calibratable Clock

Calibration circuit corrects apparent clock rate (ACR) of digital clock without altering oscillator frequency. Calibration circuit does not require iterative adjustments to reference frequency or rate, and correction to ACR is controlled by pushbuttons. Technique is applicable to any timer or counter that counts up to predetermined number then outputs a pulse to a readout register or to control another device.

Davidson, J. R.

Pulsed Phase-Locked-Loop Strain Monitor

P2sup.L2sup. strain monitor measures strain by monitoring change in phase of acoustic signal that passes through stressed sample. Phase sample causes shift in frequency of VCO. As with other monitors of this type, instrument is only accurate in elastic range of material. Monitor is expected to have broad application in materials testing, structural design, fabrication and assembly.

Heyman, J. S.

Ultrasonic measurement of axial stress

The theory of acoustic propagation in strained media is examined, with particular emphasis on rod (bolt) geometries. The continuous wave (CW) approach is the basis of the study, and the theory is developed from a frequency domain analysis standpoint in order to obtain an applied stress/normalized frequency shift relationship. CW measurements may be influenced by such factors as propagation effects, mode conversion, frequency, material properties, and geometry. After the first loading cycle, axial stress measurements for a preloading with an initial frequency of 4.995 36 MHz dropped to 4.989 19 MHz, indicating a 6.17 kHz change. CW and pseudo-CW ultrasonic techniques are found to be reliable for axial stress measurements, and acoustic attenuation measurements correlated to residual stress fields may possibly involve transducer phase cancellation. It is thus concluded that signal drop is an artifact of the transducer directivity, rather than an actual acoustic power decrease.

Heyman, J. S.

Acoustic tooth cleaner

An acoustic oral hygiene unit is described that uses acoustic energy to oscillate mild abrasive particles in a water suspension which is then directed in a low pressure stream onto the teeth. The oscillating abrasives scrub the teeth clean removing food particles, plaque, calculous, and other foreign material from tooth surfaces, interproximal areas, and tooth-gingiva interface more effectively than any previous technique. The relatively low power output and the basic design makes the invention safe and convenient for everyday use in the home without special training. This invention replaces all former means of home dental prophylaxis, and requires no augmentation to fulfill all requirements for daily oral hygienic care.

Heyman, J. S.

Liquid-immersible electrostatic ultrasonic transducer

A broadband megahertz range electrostatic acoustic transducer for use in a liquid environment is described. A liquid tight enclosure includes a metallic conducting membrane as part of its outside surface and has a means inside the liquid tight enclosure for applying a tension to the membrane and for mounting an electrode such that the flat end of the electrode is aproximately parallel to the membrane. The invention includes structure and a method for ensuring that the membrane and the flat end of the electrode are exactly parallel and a fixed predetermined distance from each other.

Cantrell, J. H., Jr.

Improved formula for continuous-wave measurements of ultrasonic phase velocity

An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.

Chern, E. J.