Engineering Papers⌕ Search

Engineering topics

Herzig, H.

Publications and source records attributed to Herzig, H..

Optical coating technology for the EUV

Advances in optical coating and materials technology are one of the key motivators for the development of missions such as the Far Ultraviolet Spectroscopic Explorer recently selected by NASA for an Explorer class mission in the mid 1990's. The performance of a range of candidate coatings are reviewed for normal-incidence and glancing-incidence applications, and attention is given to strengths and problem areas for their use in space. The importance of recent developments in multilayer films, chemical-vapor deposited SiC (CVD-SiC) mirrors, and SiC films are discussed in the context of EUV instrumentation design. For example, the choice of optical coatings is a design driver for the selection of the average glancing angle for the FUSE telescope, and impacts efficiency, short-wavelength cut-off, and physical size.

Osantowski, J. F.↗

Low earth orbit environmental effects on osmium and related optical thin-film coatings

A number of samples of optical thin film materials were flown on Shuttle flight STS-8 as part of an experiment to evaluate their interaction with residual atomic oxygen in low earth orbit. Osmium was selected because of its usefulness as a reflective optical coating for far-UV instruments and for confirmation of results from previous Shuttle flights in which such coatings disappeared. Reflectance data and photographic evidence are presented to support the hypothesis that the osmium disappearance is due to reaction with oxygen to form a volatile oxide. Platinum and iridium, which were included for comparison, fared much better.

Gull, T. R.↗

Fabrication of optical components for the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

The Solar Maximum Mission (SMM) satellite was launched in February 1980 into a 573 km high circular orbit. It contains X-ray, UV, and optical instruments for the simultaneous observation of solar flares. The ultraviolet spectrometer and polarimeter (UVSP) is one of these instruments. The objectives of the UVSP require the employment of a raster scanning telescope to study the spatial dynamics of flares, the use of a high resolution spectrometer to select and scan spectral lines for temperature and velocity diagnostics, and the utilization of a polarimeter to measure magnetic fields in the solar transition zone. The present paper has the objective to provide a description of the optical fabrication techniques developed for the instrument. Attention is given to telescope mirrors, metering rods, the Ebert mirror, grating blanks, a four-mirror polarizer, beam splitter assemblies, beam splitter fabrication, deflector mirrors, and shipping containers.

Spencer, R. S.↗

Vacuum deposition of iridium on large astronomical mirrors for use in the far UV

An iridium coating has been deposited by electron-beam evaporation on a 0.91-m mirror which serves as the telescope primary of a sounding rocket instrument for far-UV spectrometry. The evaporation was carried out by applying 8 kV at 400 mA to the electron gun. Zone refined Ir of 99.99% purity was used, and the electron beam was electromagnetically swept over the surface of the evaporant. Under these conditions, deposition rates of 0.55 A/sec were achieved. The reflectance distribution achieved at a wavelength of 584 A was extremely uniform; the mean reflectance was 21.2% with a standard deviation of only 0.3%. This represents a substantial improvement over Al + MgF2 and Al + LiF coatings for applications involving multiple reflections and weak signals, as might be expected in a high-resolution spectrograph studying distant celestial objects.

Herzig, H.↗

Vapor-deposited graded-thickness films

Rotating substrate and slotted mask allow varying film thickness to be deposited from vapor by exposing film substrate to metal vapor through circular mask. Useful for fabricating variable thickness coatings for controlling thermal, electrical, or other properties.

Herzig, H.↗

Auger spectroscopic examination of MgF2-coated Al mirrors before and after UV irradiation

Magnesium fluoride protected Al films were studied since these mirrors are commonly used in astronomical instruments whenever a highly reflecting optical surface is required in the wavelength region from 1100 A to 2000 A. Freshly prepared samples of evaporated Al + 250-A thick MgF2 on glass were analyzed by Auger electron spectroscopy in conjunction with surface erosion by Ar(+) ion bombardment before and after UV irradiation. The analysis showed that a very thin layer of surface contamination and not bulk photolysis in the MgF2 film was reponsible for the irradiation-induced reflectance loss. Postirradiation polishing with a mild calcium carbonate abrasive can restore a mirror's reflectance by removing the photolyzed surface film without disturbing the MgF2 layer.

Heaney, J. B.↗

Low-reflectivity spectrally selective coating

Mirror, with area of low reflectivity, replaces neutral-density transmission filter in star-tracking system, increasing reliability. It may have applications in other optical systems.

Zaniewski, J. J.↗