Stereo electro-optical tracker study for the measurement of model deformations at the National Transonic Facility
The effects of model vibration, camera and window nonlinearities, and aerodynamic disturbances in the optical path on the measurement of target position is examined. Window distortion, temperature and pressure changes, laminar and turbulent boundary layers, shock waves, target intensity and, target vibration are also studied. A general computer program was developed to trace optical rays through these disturbances. The use of a charge injection device camera as an alternative to the image dissector camera was examined.