Engineering Papers⌕ Search

Engineering topics

Henderson, Kevin

Publications and source records attributed to Henderson, Kevin.

Synchrotron CT imaging of lattice structures with engineered defects

Understanding mechanical failure, crack propagation, and compressive behavior at the micrometer scale is essential for tailoring material properties for structural performance in cellular materials. Typically, modeling of traditional polymer foam materials is clouded by the lack of control in material morphology and its inherent stochastic structure. Additive manufacturing with sub-micrometer resolution provides a direct path for experimenters to specifically tailor structures needed by modelers to explicitly probe mechanical performance. Using laboratory-based 3D X-ray computed tomographic imaging (CT), the examination of deformation and damage provides a critical path to understand how these soft materials behave. Additionally, synchrotron CT yields realistic information at higher strain rates to directly validate the robustness of our finite element modeling. For this study, nanolithographic printing was employed to generate a series of engineered lattices with increasing levels of defects through the random removal of ligaments. These structures were mechanically tested and imaged with laboratory-based microCT. Additionally, synchrotron experiments were conducted in which the structures were imaged in 3D at 14 Hz during compression at a 0.4 s –1 strain rate. These 3D images show the changes in the structure as the ligaments bend, buckle and fracture in real time. This technique provides a robust framework for developing our methodologies and future exploration of engineered structures.

36 MATERIALS SCIENCE↗

Progress Toward Fabrication of Machined Metal Shells for the First Double-Shell Implosions at the National Ignition Facility

The double-shell platform fielded at the National Ignition Facility requires developments in new machining techniques and robotic assembly stations to meet the experimental specifications. Current double-shell target designs use a dense high-Z inner shell, a foam cushion, and a low-Z outer shell. The design requires that the inner shell be gas filled using a fill tube. This tube impacts the entire machining and assembly design. Other intermediate physics designs have to be fielded to answer physics questions and advance the technology to be able to fabricate the full point design in the near future. One of these intermediate designs is a mid-Z imaging design. The methods of designing, fabricating, and characterizing each of the major components of an imaging double shell are discussed with an emphasis on the fabrication of the machined outer metal shell.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lithographic Printing Via Two-Photon Polymerization of Engineered Foams

Understanding deuterium-tritium mix in capsules is critical to achieving fusion within inertial confined fusion experiments. One method of understanding how the mix of hydrogen fuels can be controlled is by creating various structured deuterated foams and filling the capsule with liquid tritium. Historically, these materials have been a stochastically structured gas-blown foam. Later, to improve the uniformity of this material, pore formers have been used which are then chemically removed, leaving behind a foam of monodisperse voids. However, this technique is still imperfect in that fragments of the pore templating particles may not be completely removed and the void distribution may not be uniform over the size scale of the capsule. Recently, advances in three-dimensional printing suggest that it can be used to create microlattices and capsule walls in one single print. Demonstrated in this paper are proof-of-concept microlattices produced using two-photon polymerization with submicrometer resolution of various structures as well as a microlattice-containing capsule. Finally, with this technology, complete control of the mixing structure is possible, amenable to modeling and easily modified for tailored target design.

42 ENGINEERING↗

Synchrotron-based X-ray computed tomography during compression loading of cellular materials

Three-dimensional X-ray computed tomography (CT) of in situ dynamic processes provides internal snapshot images as a function of time. Tomograms are mathematically reconstructed from a series of radiographs taken in rapid succession as the specimen is rotated in small angular increments. In addition to spatial resolution, temporal resolution is important. Thus temporal resolution indicates how close together in time two distinct tomograms can be acquired. Tomograms taken in rapid succession allow detailed analyses of internal processes that cannot be obtained by other means. This article describes the state-of-the-art for such measurements acquired using synchrotron radiation as the X-ray source.

36 MATERIALS SCIENCE↗

The effects of gamma irradiation on RTV polysiloxane foams

The present paper involves the investigation of ionizing radiation effects on silica filled poly (dimethyl siloxane) foam vulcanized at room temperature. In order to better predict aging effects in these materials, it is important to understand the influence of irradiation on structural-rheological property relationships. Polysiloxane foams were subjected to moderate doses of gamma irradiation in an inert atmosphere and characterized by thermal (DSC and TGA), chemical (FT-IR, NMR, Mössbauer, mass spectroscopy, EPR, solvent swelling), microscopy (SEM and AFM), and mechanical (uniaxial compressive load) techniques. Radiation exposure induced cross-linking reactions that predominated over chain scission reactions for the dose range investigated. No long-lived radiation-induced radicals were detected and the porous structure of the irradiated foam remained unchanged. Finally, radiation exposure resulted in gas evolution, decrease in crystallization levels, slight changes in chemistry, and decrease in the molecular weight between cross-links, thereby hardening the foam.

36 MATERIALS SCIENCE↗

Ultraviolet stimulated electron source for use with low energy plasma instrument calibration

We have developed and demonstrated a versatile, compact electron source that can produce a mono-energetic electron beam up to 50 mm in diameter from 0.1 to 30 keV with an energy spread of <10 eV. By illuminating a metal cathode plate with a single near ultraviolet light emitting diode, a spatially uniform electron beam with 15% variation over 1 cm{sup 2} can be generated. A uniform electric field in front of the cathode surface accelerates the electrons into a beam with an angular divergence of <1 Degree-Sign at 1 keV. The beam intensity can be controlled from 10 to 10{sup 9} electrons cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗

Development of a fast position-sensitive laser beam detector

We report the development of a fast position-sensitive laser beam detector. The detector uses a fiber-optic bundle that spatially splits the incident beam, followed by a fast balanced photodetector. The detector is applied to the study of Brownian motion of particles on fast time scales with 1 A spatial resolution. Future applications include the study of molecule motors, protein folding, as well as cellular processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗