X-ray Diode Preparation

A rod pinch x-ray diode assembly culminates in a coaxial anode cathode arrangement where a small anode rod extends through the aperture of a cathode plate. Shotto- shot repeatability in rod placement, and thus x-ray source spot position, has potential to positively affect radiographic image quality. Thus, how to both control and measure, according to a Cartesian coordinate system, anode rod tip displacement (x, y) (off the beam line-of-sight retical) and also anode rod tip extension (z) (along the line-of-sight center line) become salient issues relative to radiographic image set utility. To address these issues both hardware fabrication and x-ray diode assembly methods were reviewed, and additional controls were introduced. A photogrammetric procedure was developed to quantify anode rod tip position in situ. Computer models and mock-up assemblies with precision fiducials were produced to validate this procedure. Therefore, both anode rod tip displacement and anode rod tip extension parameters were successfully controlled. Rod position was measured and met the required specifications: (1) radial displacement <0.25 mm and (2) axial placement of ±0.25 mm. We demonstrated that precision control and measurement of large scale components is achievable in a pulse power system (i.e., hardware and operations). Correlations with diode performance and radiography are presented.

42 ENGINEERING↗

Determination of the E1 component of the low-energy {sup 12}C(alpha,gamma){sup 16}O cross section

A measurement of the beta-delayed alpha decay of {sup 16}N using a set of twin ionization chambers is described. Sources were made by implantation, using a {sup 16}N beam produced via the In-Flight Technique. The energies and emission angles of the {sup 12}C and alpha particles were measured in coincidence and very clean alpha spectra, down to energies of 450 keV, were obtained. The structure of the spectra from this experiment is in good agreement with results from previous measurements. An analysis of our data with the same input parameters as used in earlier studies gives S{sub E1}(300)=86+-22 keVb for the E1 component of the S-factor. This value is in excellent agreement with results obtained from various direct and indirect measurements. In addition, the influence of new measurements including the phase shift data from Tischhauser et al. on the value of S{sub E1}(300) is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fusion hindrance for {sup 27}Al+{sup 45}Sc and other systems with a positive Q value

Fusion evaporation cross sections for the {sup 27}Al+{sup 45}Sc (Q=9.63 MeV) system are measured down to about 300 nb. Deviations from standard coupled-channels calculations were observed in this system at the lowest energies. The steep fall-off of the fusion cross sections can be reproduced by calculations using a shallow potential model, which was originally developed to explain the hindrance behavior of heavy-ion fusion in medium-mass systems with negative Q values. Comparisons of the hindrance behavior between the present experiment and other systems, for example, {sup 28}Si+{sup 30}Si (Q=14.3 MeV) and {sup 36}S+{sup 48}Ca (Q=7.55 MeV) are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure of {sup 7}He by proton removal from {sup 8}Li with the (d,{sup 3}He) reaction

We report on a study of the structure of the unbound nucleus {sup 7}He utilizing the proton-removal reaction {sup 2}H({sup 8}Li,{sup 3}He){sup 7}He. Combining the present results with those of our prior measurements of the neutron-adding reaction {sup 2}H({sup 6}He,p){sup 7}He, a consistent picture emerges for the low-lying excitations in {sup 7}He. Specifically, the negative-parity sequence of resonances, in order of excitation energies, is consistent with 3/2{sup -},1/2{sup -}, and 5/2{sup -}. The stable-beam reactions {sup 2}H({sup 7}Li,t){sup 6}Li and {sup 2}H({sup 7}Li,{sup 3}He){sup 6}He were also measured. The results are compared with the predictions of nuclear structure models, including those of ab initio quantum Monte Carlo calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fusion hindrance for a positive Q-value system

An excitation function for the fusion reaction {sup 28}Si + {sup 30}Si (Q=14.3MeV) has been measured down to 40{mu}b. Deviations from the behavior predicted by the optical model and standard coupled-channels calculations have been observed in this system. The fusion cross sections can be reproduced by a shallow potential model well, which was originally developed to explain the hindrance of heavy-ion fusion for systems with negative Q-values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Structure of {sup 7}He

We have studied the properties of the unbound isotope of helium {sup 7}He, using the {sup 2}H({sup 8}Li,{sup 3}He){sup 7}He reaction. When combined with prior measurements of the {sup 2}H({sup 6}He,p){sup 7}He reaction the data present a consistent picture for the low-lying excited states of {sup 7}He, specifically the negative parity sequence 3/2{sup -} (ground state) 1/2{sup -} (first-excited) and 5/2{sup -} (second-excited). The shapes but not the absolute magnitudes of the angular distributions are reproduced by ab-initio theory coupled with a DWBA reaction framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing recoil-isomer tagging with the Argonne fragment mass analyzer.

A new focal plane detector arrangement for the Fragment Mass Analyzer (FMA) has been built and tested at Argonne National Laboratory. This set-up is particularly sensitive for performing Recoil-Isomer Tagging on nuclei with isomeric states with lifetimes in the microsecond range. Recoiling nuclei from fusion--evaporation reactions at the target position are dispersed by their ratio of mass to charge (A/q) by the FMA and stopped in low pressure gas (air) at the focal plane. Subsequent gamma decays from isomeric states in the reaction products are observed using Ge detectors. A constant gas flow through the focal plane chamber efficiently removes longer-lived beta-decaying species from sight of the detectors. This set-up has been commissioned successfully with the microsecond isomer in {sup 80}Rb, populated via the {sup 52}Cr({sup 32}S, 3pn) reaction at 135 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗