Engineering Papers⌕ Search

Engineering topics

Heimbigner, Tom R

Publications and source records attributed to Heimbigner, Tom R.

LaCl3:Ce Coincidence Signatures to Calibrate Gamma-ray Detectors

Abstract Calibrating the gamma-ray detection efficiency of radiation detectors in a field environment is difficult under most circumstances. To counter this problem we have developed a technique that uses a Cerium doped Lanthanum-Tri-Chloride (LaCl3:Ce) scintillation detector to provide gated gammas[ , ]. Exploiting the inherent radioactivity of the LaCl3:Ce due to the long-lived radioactive isotope 138La (t1/2 = 1.06 x 1011 yrs) allows the use of the 788 and 1436-keV gammas as a measure of efficiency. In this paper we explore the effectiveness of using the beta-gamma coincidences radiation LaCl3:Ce detector to calibrate the energy and efficiency of a number of gamma-ray detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference Terms for Xenon-135

Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in Advanced Spectral Analysis of Radioxenon

Improvements to a Java based software package developed at Pacific Northwest National Laboratory (PNNL) for display and analysis of radioxenon spectra acquired by the International Monitoring System (IMS) are described here. The current version of the Radioxenon JavaViewer implements the region of interest (ROI) method for analysis of beta-gamma coincidence data. Upgrades to the Radioxenon JavaViewer will include routines to analyze high-purity germanium detector (HPGe) data, Standard Spectrum Method to analyze beta-gamma coincidence data and calibration routines to characterize beta-gamma coincidence detectors. These upgrades are currently under development; the status and initial results will be presented. Implementation of these routines into the JavaViewer and subsequent release is planned for FY 2011-2012.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Neural Network Based State of Health Diagnostics for an Automated Radioxenon Sampler/Analyzer

Artificial neural networks (ANNs) are used to determine the state-of-health (SOH) of the Automated Radioxenon Analyzer/Sampler (ARSA). ARSA is a gas collection and analysis system used for non-proliferation monitoring in detecting radioxenon released during nuclear tests. SOH diagnostics are important for automated, unmanned sensing systems so that remote detection and identification of problems can be made without onsite staff. Both recurrent and feed-forward ANNs are presented. The recurrent ANN is trained to predict sensor values based on current valve states, which control air flow, so that with only valve states the normal SOH sensor values can be predicted. Deviation between modeled value and actual is an indication of a potential problem. The feed-forward ANN acts as a nonlinear version of principal components analysis (PCA) and is trained to replicate the normal SOH sensor values. Because of ARSA’s complexity, this nonlinear PCA is better able to capture the relationships among the sensors than standard linear PCA and is applicable to both sensor validation and recognizing off-normal operating conditions. Both models provide valuable information to detect impending malfunctions before they occur to avoid unscheduled shutdown. Finally, the ability of ANN methods to predict the system state is presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SPECTRAL ANALYSIS OF RADIOXENON

Monitoring changes in atmospheric radioxenon concentrations is a major tool in the detection of an underground nuclear explosion. Ground based systems like the Automated Radioxenon Sampler /Analyzer (ARSA), the Swedish Unattended Noble gas Analyzer (SAUNA) and the Automatic portable radiometer of isotopes Xe (ARIX), can collect and detect several radioxenon isotopes by processing and transferring samples into a high efficiency beta-gamma coincidence detector. The high efficiency beta-gamma coincidence detector makes these systems highly sensitive to the radioxenon isotopes 133Xe, 131mXe, 133mXe and 135Xe. The standard analysis uses regions of interest (ROI) to determine the amount of a particular radioxenon isotope present. The ROI method relies on the peaks of interest falling within energy limits of the ROI. Some potential problems inherent in this method are the reliance on stable detector gains and a fixed resolution for each energy peak. In addition, when a high activity sample is measured there will be more interference among the ROI, in particular within the 133Xe, 133mXe, and 131mXe regions. A solution to some of these problems can be obtained through spectral fitting of the data. Spectral fitting is simply the fitting of the peaks using known functions to determine the number and relative peak positions and widths. By knowing this information it is possible to determine which isotopes are present. Area under each peak can then be used to determine an overall concentration for each isotope. Using the areas of the peaks several key detector characteristics can be determined: efficiency, energy calibration, energy resolution and ratios between interfering isotopes (Radon daughters).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

GENERATION OF RADIOXENON ISOTOPES

With the continued population of the International Monitoring System (IMS) network and the certification of radioxenon laboratory systems it has become necessary to calibrate and test these systems using as many of the radioxenon isotopes as possible. Several very promising techniques have been explored recently that allow for convenient production of Xe-133, Xe-131m, the short-lived isotope Xe-135, and even the difficult to obtain Xe-133m. IMS national and international laboratories have traditionally obtained Xe-133 from medical isotope suppliers. The activity of these medical dose samples is extremely high (~ 740 MBq) and requires very careful fume hood work to dilute down to appropriate levels (~ 10 Bq). By waiting for 10 or more half-lives it is possible to reduce the handling regimen considerably, while also obtaining a strong Xe-131m signature due to its longer half-life (11.9 days). The short-lived isotope Xe-135 (9.14 hrs) and the longer lived parent nuclide Xe-133m (2.2 day half-life) are never present in these samples. To obtain these isotopes another source or technique is required. This paper will discuss the two techniques developed and implemented at Pacific Northwest National Lab (PNNL) and show the results obtained from each technique. The first is an in-house method that allows for on demand production of two of these isotopes, Xe-133 and Xe-135, using HEU and a modest flux neutron source. The second method uses a research reactor at the Pullman campus of Washington State University to produce Xe-133, Xe-133m and Xe-135.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Beta-cell Assembly for the Quad Gas Sampling Detector

The beta-cells used in the beta-gamma detector have taken time to develop and to standardize the assembly of them. In making the assembly routine it is important to have step by step assembly instructions as well as a list of potential problems and their solutions. This document attempts to accomplish these goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗