Enhancing the Chemical Energy Flux in a High-Temperature Tubular Counterflow Solid Fuel Synthesis Reactor Using a Bypass
Redox reactions of metal oxides offer a path towards using intermittent renewable resources for high-density thermochemical energy storage. Thermochemical energy storage often involves the flow of a particulate media. We describe a novel method to increase the throughput in a gravity-driven high-temperature thermochemical storage reactor flowing pelletized MgMnO. The moving bed reactor operates under counter-flow conditions and encounters particle flowability problems at temperatures of 1500 °C leading to sintering of the bed. Inertial forces of a counter-flowing gas can overcome the gravitational forces on the particles and limit the chemical energy storage rate of the reactor. We found that the insertion of a gas bypass (a slotted tube) into the reactor results in a 100% increase of the flow rates and achieved a 50% higher chemical energy storage flux compared to the operation without a bypass tube while mitigating the effects of sintering on the particles. As a result, the higher solid flow rates require a longer heated zone to reach a comparable residence time and extent of reduction compared to the lower flow rates.
Experimental demonstration of high-temperature (>1000 °C) heat extraction from a moving-bed oxidation reactor for thermochemical energy storage
Previously developed reduction-oxidation (redox) thermochemical energy storage technologies must store their products at high temperatures, complicating handling and transportation. This work describes a countercurrent, tubular, moving bed oxidation reactor at laboratory scale that produces high grade heat and allows solids to enter and exit the system at ambient temperatures. The particles implemented in the system consist of a novel magnesium manganese-oxide material well-suited for thermochemical energy storage. Output heat is obtained via a separate extraction gas flow, which exits from the middle portion of the main reactor tube. With this design, reactor temperatures in excess of 1000°C and extraction temperatures above 950°C were achieved. Deviation between the two measurements is a result of extraction thermocouple placement and losses in the reactor extraction arm; improvements to these parameters would bring the extraction temperature closer to the bed temperature. The reactor produces enough energy via oxidation to sustain both heat extraction and continued chemical reaction. During one representative steady state experiment at a particle flow rate of 1.5 g/s, an average of 447 W was extracted from the reactor out of an estimated 1083 W of released chemical energy for a duration of 70 minutes. Among the four experiments, the maximum bench-scale oxidation reactor energy efficiency of 36.2% and corresponding round-trip efficiency of 13.7% considering both redox reactors were demonstrated. Characteristics of an ideal system are considered and future improvements are proposed.
A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage
The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.
Implementation of a Model Predictive Control Strategy to Regulate Temperature Inside Plug-Flow Solar Reactor With Countercurrent Flow
Abstract Solar-driven thermochemical energy storage systems are proven to be promising energy carriers (solar fuels) to utilize solar energy by using reactive solid-state pellets. However, the production of solar fuel requires a quasi-steady-state process temperature, which represents the main challenge due to the transient nature of solar power. In this work, an adaptive model predictive controller (MPC) is presented to regulate the temperature inside a tubular solar reactor to produce solid-state solar fuel for long-term thermal storage systems. The solar reactor system consists of a vertical tube heated circumferentially over a segment of its length by concentrated solar power, and the reactive pellets (MgMn2O4) are fed from the top end and flow downwards through the heated tube. A countercurrent flowing gas supplied from the lower end interacts with flowing pellets to reduce it thermochemically at a temperature range of 1000—1500 °C. A low-order physical model was developed to simulate the dynamics of the solar reactor including the reaction kinetics, and the proposed model was validated numerically by using a 7-kW electric furnace. The numerical model then was utilized to design the MPC controller, where the control system consists of an MPC code linked to an adaptive system identification code that updates system parameters online to ensure system robustness against external disturbances (sudden change in the flow inside the reactor), model mismatches, and uncertainty. The MPC controller parameters are tuned to enhance the system performance with minimum steady-state error and overshoot. The controller is tested to track different temperature ranges between 500 °C and 1400 °C with different particles/gas mass flowrates and ramping temperature profiles. Results show that the MPC controller successfully regulated the reactor temperature within ± 1 °C of its setpoint and maintained robust performance with minimum input effort when subjected to sudden changes in the amount of flowing media and the presence of chemical reaction.
Zero carbon solid-state rechargeable redox fuel for long duration and seasonal storage
Here, this work presents a unique thermochemical process for charging magnesium-manganese-oxide-based solid-state rechargeable redox fuel. High-temperature heating of the processing furnace can be driven by either renewable electricity or concentrated solar power. The simple recyclable fuel charging concept is based on a tubular falling bed reactor with countercurrent oxygen-depleted gas flow for complete heat recuperation. The main focus of this work is achieving solid flowability at high temperatures (1,450°C) and extracting chemically charged solid at ambient temperature with minimal energy loss. The operation strategies described in this work have enabled consistent magnesium-manganese-oxide particle flow up to 1,450°C. The measured extent of the thermal reduction reaction after cooling the particles is more than 90% of the fully reduced state at equilibrium. The thermal-to-chemical efficiency and overall system efficiency are 96% and 35% respectively, which are the highest reported for thermochemical fuels to date.
Design of a Combined Proportional Integral Derivative Controller to Regulate the Temperature Inside a High-Temperature Tubular Solar Reactor
Solar fuels are proven to be promising candidates for thermochemical energy storage. However, the transient nature of solar radiation is an obstacle to maintaining a stable operational temperature inside a solar reactor. To overcome this challenge, the temperature of a solar reactor can be regulated by controlling the incoming solar radiation or the feedstock flowrate inside the reactor. In this work, a combined proportional integral derivative (PID) controller is implemented to regulate the temperature inside a high-temperature tubular solar reactor with counter-current flowing gas/particles. The control model incorporates two control systems to regulate incoming solar radiation and gas flow simultaneously. The design of the controller is based on a reduced-order numerical model of a high-temperature tubular solar reactor that is vertically oriented with an upward gas flow and downward particle flow. The reactor receives heat circumferentially through its wall over a finite segment of its length. Formulation of the heat transfer model is presented by applying the energy balance for the reactor tube and considering heat and mass transfer inside. A set of governing differential equations are solved numerically by using the finite volume method to obtain reactor wall, particles, and gas temperatures along the reactor length with various boundary conditions. Simulation results are used to tune the PID controller parameters by utilizing the Ziegler–Nichols tuning method. Both the simulation results and the controller performance are visualized on the LABVIEW platform. The controller is challenged to track different temperature setpoints with different scenarios of transient solar radiation. Here, the performance of the PID controller was compared to experimental results obtained from an industrial PID controller embedded in a 7 kW electric furnace. Results show that the combined PID controller is successful in maintaining a stable temperature inside the reactor by regulating the incoming solar radiation and the flowrate via small steady-state error and reasonable settling time and overshoot.