Engineering topics
Hassan, A
Publications and source records attributed to Hassan, A.
Synthesis Structure and Imaging of Oligodeoxyribonucleotides with Tellurium-nucleobase Derivatization
We report here the first synthesis of 5-phenyl-telluride-thymidine derivatives and the Te-phosphoramidite. We also report here the synthesis, structure and STM current-imaging studies of DNA oligonucleotides containing the nucleobases (thymine) derivatized with 5-phenyl-telluride functionality (5-Te). Our results show that the 5-Te-DNA is stable, and that the Te-DNA duplex has the thermo-stability similar to the corresponding native duplex. The crystal structure indicates that the 5-Te-DNA duplex structure is virtually identical to the native one, and that the Te-modified T and native A interact similarly to the native T and A pair. Furthermore, while the corresponding native showed weak signals, the DNA duplex modified with electron-rich tellurium functionality showed strong topographic and current peaks by STM imaging, suggesting a potential strategy to directly image DNA without structural perturbation.
High Fidelity of Base Paring by 2-Selenothymidine in DNA
The base pairs are the contributors to the sequence-dependent recognition of nucleic acids, genetic information storage, and high fidelity of DNA polymerase replication. However, the wobble base pairing, where T pairs with G instead of A, reduces specific base-pairing recognition and compromises the high fidelity of the enzymatic polymerization. Via the selenium atomic probing at the 2-position of thymidine, we have investigated the wobble discrimination by manipulating the steric and electronic effects at the 2-exo position, providing a unique chemical strategy to enhance the base pair specificity. We report here the first synthesis of the novel 2-Se-thymidine ({sup Se}T) derivative, its phosphoramidite, and the Se-DNAs. Our biophysical and structural studies of the 2-Se-T DNAs reveal that the bulky 2-Se atom with a weak hydrogen-bonding ability can largely increase mismatch discriminations (including T/G wobble and T/C mismatched base pairs) while maintaining the {sup Se}T/A virtually identical to the native T/A base pair. The 2-Se atom bulkiness and the electronic effect are probably the main factors responsible for the discrimination against the formation of the wobble {sup Se}T/G base pair. Our investigations provide a potential novel tool to investigate the specific recognition of base pairs, which is the basis of high fidelity during replication, transcription, and translation. Furthermore, this Se-atom-specific substitution and probing are useful for X-ray crystal structure and function studies of nucleic acids.
Synthesis and Crystallographic Analysis of 5-Se-Thymidine DNAs
We investigated the possibility of the interaction of 5-CH3 of thymidine and its 5?-phosphate backbone (C-H O-PO3 interaction) in DNA via the insertion of the atomic probe (a selenium atom) into the exo-5-position of thymidine (5-Se-T). 5-Se-T was synthesized for the first time, via Mn(OAc)3 assisted electrophilic addition of CH3SeSeCH3 to 3?,5?-di-O-benzoyl-2?-deoxyuridine. The 5-Se-T phosphoramidite was subsequently synthesized and incorporated into DNA in over 99% coupling yield. Biophysical and structural investigations of the 5-Se-T DNAs revealed that the Se-modified and nonmodified DNAs are virtually identical. In addition, the crystallographic analysis of a 5-Se-T DNA strongly suggests a hydrogen-bond formation between the 5-CH3 and 5?-phosphate groups (CH3 PO4- interaction).
Validation Analysis of the Shoal Groundwater Flow and Transport Model
Environmental restoration at the Shoal underground nuclear test is following a process prescribed by a Federal Facility Agreement and Consent Order (FFACO) between the U.S. Department of Energy, the U.S. Department of Defense, and the State of Nevada. Characterization of the site included two stages of well drilling and testing in 1996 and 1999, and development and revision of numerical models of groundwater flow and radionuclide transport. Agreement on a contaminant boundary for the site and a corrective action plan was reached in 2006. Later that same year, three wells were installed for the purposes of model validation and site monitoring. The FFACO prescribes a five-year proof-of-concept period for demonstrating that the site groundwater model is capable of producing meaningful results with an acceptable level of uncertainty. The corrective action plan specifies a rigorous seven step validation process. The accepted groundwater model is evaluated using that process in light of the newly acquired data. The conceptual model of ground water flow for the Project Shoal Area considers groundwater flow through the fractured granite aquifer comprising the Sand Springs Range. Water enters the system by the infiltration of precipitation directly on the surface of the mountain range. Groundwater leaves the granite aquifer by flowing into alluvial deposits in the adjacent basins of Fourmile Flat and Fairview Valley. A groundwater divide is interpreted as coinciding with the western portion of the Sand Springs Range, west of the underground nuclear test, preventing flow from the test into Fourmile Flat. A very low conductivity shear zone east of the nuclear test roughly parallels the divide. The presence of these lateral boundaries, coupled with a regional discharge area to the northeast, is interpreted in the model as causing groundwater from the site to flow in a northeastward direction into Fairview Valley. Steady-state flow conditions are assumed given the absence of groundwater withdrawal activities in the area. The conceptual and numerical models were developed based upon regional hydrogeologic investigations conducted in the 1960s, site characterization investigations (including ten wells and various geophysical and geologic studies) at Shoal itself prior to and immediately after the test, and two site characterization campaigns in the 1990s for environmental restoration purposes (including eight wells and a year-long tracer test). The new wells are denoted MV-1, MV-2, and MV-3, and are located to the northnortheast of the nuclear test. The groundwater model was generally lacking data in the north-northeastern area; only HC-1 and the abandoned PM-2 wells existed in this area. The wells provide data on fracture orientation and frequency, water levels, hydraulic conductivity, and water chemistry for comparison with the groundwater model. A total of 12 real-number validation targets were available for the validation analysis, including five values of hydraulic head, three hydraulic conductivity measurements, three hydraulic gradient values, and one angle value for the lateral gradient in radians. In addition, the fracture dip and orientation data provide comparisons to the distributions used in the model and radiochemistry is available for comparison to model output. Goodness-of-fit analysis indicates that some of the model realizations correspond well with the newly acquired conductivity, head, and gradient data, while others do not. Other tests indicated that additional model realizations may be needed to test if the model input distributions need refinement to improve model performance. This approach (generating additional realizations) was not followed because it was realized that there was a temporal component to the data disconnect: the new head measurements are on the high side of the model distributions, but the heads at the original calibration locations themselves have also increased over time. This indicates that the steady-state assumption of the groundwater model is in error. To test the robustness of the model despite the transient nature of the heads, the newly acquired MV hydraulic head values were trended back to their likely values in 1999, the date of the calibration measurements. Additional statistical tests are performed using both the backward-projected MV heads and the observed heads to identify acceptable model realizations. A jackknife approach identified two possible threshold values to consider. For the analysis using the backward-trended heads, either 458 or 818 realizations (out of 1,000) are found acceptable, depending on the threshold chosen. The analysis using the observed heads found either 284 or 709 realizations acceptable. The impact of the refined set of realizations on the contaminant boundary was explored using an assumed starting mass of a single radionuclide and the acceptable realizations from the backward-trended analysis.
ABSTRACT: Design of Groundwater Monitoring Networks Considering Conceptual Model and Parametric Uncertainty
Uncertainty built into conceptual groundwater flow and transport models and associated parametric uncertainty should be appropriately included when such models are used to develop detection monitoring networks for contaminated sites. We compare alternative approaches of propagating such uncertainty from the flow and transport model into the network design. The focus is on detection monitoring networks where the primary objective is to intercept the contaminant before it reaches a boundary of interest (e.g., compliance boundary). Different uncertainty propagation approaches identify different well locations and different well combinations (networks) as having the highest detection efficiency. It is thus recommended that multiple uncertainty propagation approaches are considered. If several approaches yield consistent results in terms of identifying the best performing candidate wells and the best performing well network for detecting a contaminant plume, this would provide confidence in the suitability of the selected well locations.
Design and operating characteristics of new type cold cathode ion source
In this work, the design and performance of new type ion source are described. The discharge mechanism of the source is based on creating an arc discharge through a saddle electric field inside the discharge tube. The saddle electric field is created by immersing an annular anode inside the discharge tube covered from the upper and lower ends with two flanges. These two flanges act as cathodes. The discharge tube is surrounded by a solenoid coil which produces an axial magnetic field (up to 400 G) measured at the center of the source. Measurements have been performed to find out the influence of arc power, pressure, discharge voltage, magnetic field, and extracting voltage on the ion source properties. The source yields an argon ion current of {approx}0.6 mA and electron current of {approx}4 mA at normal operating conditions (extraction voltage V{sub ex}=7 kV, pressure of 5.5x10{sup -4} Torr, V{sub arc}=400 V, I{sub arc}=1 A, B=200 G). It showed an energy spread of 20 eV at a discharge voltage of 400 V and an extraction voltage of 3 kV.