Engineering Papers⌕ Search

Engineering topics

Hasandka, Adarsh

Publications and source records attributed to Hasandka, Adarsh.

29 records · Page 2

NREL’s Cyber-Energy Emulation Platform for Research and System Visualization

This paper presents NREL’s Cyber Energy Emulation (CEE) Platform. This is a novel emulation platform for achieving real-time visualization of large-scale environments involving cyber-physical devices. It allows for the environment to include real, physical hardware, along with emulated devices communicating with each other as part of the same system. The CEE Platform is also capable of streaming, collecting, storing, transporting, and visualizing all data within the emulated environment. By providing this capability, it enables high-fidelity visual analysis of events to be performed in real time as well as the use of historical data for forensic analysis. This paper presents the design of the CEE Platform as well as several potential use cases and applications. It also aims to highlight why this type of visualization tool has potential for research and education about cyber-physical systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

Opportunistic Hybrid Communications Systems for Distributed PV Coordination

A full-scale, operational implementation of the opportunistic hybrid communications systems for distributed photovoltaic (PV) coordination was successfully developed, simulated, and validated in this 3-year project. The system is considered hybrid because it uses different communications pathways from the scale of residential PV inverters to a transmission network; primary technologies harnessed include Low-Power Wireless Personal Area Network (LoWPAN), Power Line Communication (PLC), WiFi mesh, Worldwide Interoperability for Microwave Access (WiMAX), Ethernet cable, and Optical Ethernet systems. It is opportunistic in that it chooses to route messages through each of these systems based on recent data about latency and availability to ensure reliable message passing.

14 SOLAR ENERGY↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guide to the Distributed Energy Resources Cybersecurity Framework

In May 2018, the U.S. Department of Energy (DOE) released its Cybersecurity Strategy document, a multiyear plan specifically regarding cybersecurity in the energy sector. The framework outlined in this report aligns with strategies identified in the DOE Cybersecurity Strategy document to deliver cybersecurity solutions and continually improve cybersecurity posture. Researchers from federal facilities and industry can now make use of this framework, the Distributed Energy Resources Cybersecurity Framework (DERCF), through a web-based application. This report provides an overview of the DERCF and serves as a guide to applying this framework to DERs. It also provides guidance on a method to conduct a cybersecurity assessment, using the controls presented in Appendix A.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Hybrid Smart Grid Communication Network Designs for Distributed Energy Resources Coordination

The rapid growth of distributed energy resources (DERs) has prompted increasing interest in the monitoring and control of DERs through hybrid smart grid communications. This paper develops a new method to investigate the impact of DER penetrations and applications on hybrid communications network designs. A suite of hybrid communications simulation models are developed using Network Simulator 3 (ns-3). The smart grid communications topologies with different DER penetrations are built on the utility-scale distribution grid. The simulation results show that (i) with increasing photovoltaic penetrations, nine hybrid communications designs achieve the expected latency albeit with higher packet loss rate; and (ii) both BPLC-Ethernet and BPLC-WiMAX designs can accommodate the DER applications with a high data rate up to 100 Mbps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cryptography Considerations for Distributed Energy Resource Systems

Distributed energy resource (DER) systems are rapidly being adopted and integrated within the electric power grid. Developments in smart grid devices and communication protocols are advancing the power system domain but are also introducing new cyber attack vectors. In particular, the ability to maintain the confidentiality, integrity, and availability of data is of increasing concern. Cryptography is a powerful tool that can be leveraged to protect DER systems and their critical information. This paper discusses prominent methods of cryptographic authentication and encryption that can be used to secure DER communications. Specific considerations and recommendations for applying cryptography to DER systems are provided, including system design constraints and system impact. These will be demonstrated with two case studies that assess cryptography hardware requirements and communications latency in DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of System and Interoperability Impact from Securing Communications for Distributed Energy Resources

As the power grid incorporates increasing amounts of distributed energy resources (DER) that provide new generation sources, new opportunities are created for improving operation of the grid while large challenges also arise for preserving grid reliability and security. To improve grid performance, DERs can be utilized to provide important support functionality, such as supporting frequency and voltage levels, especially if they are assisted by communication schemes as part of an advanced distribution management system (ADMS). Unfortunately, such connectivity and grid support functionality also creates additional cyber security risk with the potential for degradation of grid services, especially under conditions with high amounts of distributed generation. This paper will first discuss the communications needed by DERs to support system and interoperability objectives, as well as the security requirements and impact of securing these communications. Some common security mechanisms are discussed in relation to DERs, and a simulated 15-bus model of a distribution feeder is used to demonstrate aspects of the DER communications and impact to grid performance. These results help to advance understanding of the benefits, requirements, and mechanisms for securely implementing DER communications while ensuring that grid reliability is maintained.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation-Based Parameter Optimization Framework for Large-Scale Hybrid Smart Grid Communications Systems Design

The design of reliable, dynamic, fault-tolerant hybrid smart grid communication networks is a challenge to achieve for autonomous power grids. Hybrid networks use different communications technologies for different area networks. A simulation-based parameter optimization framework is proposed to tune parameters of hybrid communication technologies to achieve the optimal network performance. It consists of three main components: a parallel executor used to speedup a list of simulations; a sampler running simulations using the parallel executor at each generation; and a hybrid stochastic optimization algorithm for tuning configurable parameters of hybrid designs and applications. The proposed hybrid metaheuristic optimization algorithm combines an evolutionary algorithm with a gradient method to quickly achieve an approximately global optimum solution. Three optimization test functions are employed to train the adjustable parameters of the hybrid algorithm. Results show the proposed parameter optimization framework can help the designer choose the right hybrid architecture with an optimal parameter set for a large-scale broadband PLC-WiMAX hybrid smart grid communication network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Communication Architectures for Distributed Smart Grid Applications

Wired and wireless communications both play an important role in the blend of communications technologies necessary to enable future smart grid communications. Hybrid networks exploit independent mediums to extend network coverage and improve performance. However, whereas individual technologies have been applied in simulation networks, as far as we know there is only limited attention that has been paid to the development of a suite of hybrid communication simulation models for the communications system design. Hybrid simulation models are needed to capture the mixed communication technologies and IP address mechanisms in one simulation. To close this gap, we have developed a suite of hybrid communication system simulation models to validate the critical system design criteria for a distributed solar Photovoltaic (PV) communications system, including a single trip latency of 300 ms, throughput of 9.6 Kbps, and packet loss rate of 1%. In conclusion, the results show that three low-power wireless personal area network (LoWPAN)-based hybrid architectures can satisfy three performance metrics that are critical for distributed energy resource communications.

24 POWER TRANSMISSION AND DISTRIBUTION↗