The heat pipe thermal canister

The thermal canister represents a new approach to instrument thermal control for Shuttle experiments which require tight temperature control. The canister substitutes a known, benign thermal environment for the variable and uncertain environment of space, the space environment being neutralized by a system of feedback controlled variable conductance heat pipes. A proto-flight unit has been fabricated and this paper describes the acceptance thermal vacuum test results of the thermal canister experiment which will fly on an early Space Shuttle flight.

Harwell, W.

The OAO heat pipes - 8 1/2 years of flight data

Heat pipe performance data taken during the 8 1/2 years of flight of the OAO-C (Copernicus) spacecraft are presented. Three fixed conductance heat pipes (FCHP), each with different wicking concepts (axial groove, pedestal artery, and self-priming spiral artery), and one variable conductance heat pipe (VCHP) are onboard. Aluminum tubes (1/2 in. diameter) rolled into a 48 in. loop containing ultra high purity ammonia as the heat transfer fluid comprise all FCHP, whose purpose is to circumferentially isothermalize the central tube housing the telescope. The VCHP is a hot, non-wicked reservoir concept including a composite artery and methanol heat transfer fluid, and is used to maintain the temperature of the onboard processor. Flight thermal data analysis reveals that no degradation in performance occurred since launch and agrees well with pre-flight data; the onboard processor still shows an offset in control range of 4 F, and the pipes perform the same after 8 1/2 years in orbit.

Harwell, W.

Instrument canister thermal control

A transient thermal analysis and test of a thermal control canister is described. The 1 x 1 x 3 m canister provides a uniform thermal environment for shuttle instrument payloads requiring fine temperature control, the design goal being operation between 0 C and 20 C with a range of plus or minus 1 C at any selected set-point temperature. The canister side walls are isothermalized by a system of longitudinal and circumferential heat pipes rejecting heat through feedback controlled, variable conductance heat pipes to side mounted radiators. A breadboard model of two side walls and two radiators was tested in a thermal vacuum chamber. The breadboard was stable over a wide range of effective environments, experiment dissipations, and control point temperature levels.

Harwell, W.

Re-entrant groove heat pipe

This paper describes theoretical and experimentally verified heat pipe characteristics of an axially grooved aluminum extrusion with a re-entrant groove profile. The extrusion is 13 mm diameter with 20 axial grooves, each groove consisting of a nominal .8 mm diameter channel with a .2 mm wide passageway connecting the channel to the hollow core. A computer program was written to compute the zero gravity heat transport capability of the extrusion. A heat pipe was fabricated and its performance characteristics measured. The characteristics of the pipe with ammonia at 20 C are: zero gravity pumping limit 143 w-meters; static wicking height 21.5 mm; evaporator and condenser coefficients 7300 and 20,500 watt/sq m C, respectively.

Harwell, W.

The International Heat Pipe Experiment

On October 4, 1974, the International Heat Pipe Experiment was launched aboard a Black Brant sounding rocket from White Sands, New Mexico. The flight provided six min of near zero gravity during which a total of ten separate heat pipe experiments was performed. The fifteen heat pipes tested represent some of the latest American and European technology. This flight provided the first reported zero gravity data on cryogenic and flat plate vapor chamber heat pipes. Additionally, valuable design and engineering data were obtained on several other heat pipe configurations. The payload and several of its experiments are discussed.

Mcintosh, R.

The International Heat Pipe Experiment

The aims of the experiment are outlined. Flight experiments included in this program were provided by NASA, Goddard Space Flight Center, ESA (European Space Agency), the German Ministry of Technology, Hughes Aircraft Company and NASA, Ames Research Center.

Mcintosh, R.

The International Heat Pipe Experiment

On October 4, 1974 the International Heat Pipe Experiment was launched aboard a Black Brant Sounding Rocket from White Sands, New Mexico. The flight provided six minutes of near zero gravity during which a total of ten separate heat pipe experiments were performed. The fifteen heat pipes which were tested represent some of the latest American and European technology. This flight provided the first reported zero gravity data on cryogenic and flat plate vapor chamber heat pipes. Additionally, valuable design and engineering data was obtained on several other heat pipe configurations. This paper will discuss the payload and four of the individual experiments.

Mcintosh, R.

Cryogenic heat pipe experiment - Flight performance onboard a sounding rocket

Flight data from a 15.8 mm OD, 760 mm long, axial-groove, methane cryogenic heat pipe verified successful priming and operation during six min of zero-g time. The nominal power applied to the evaporator was 60-w for the first 60 sec of zero-g time, 14 w for the next 270 sec, and 25 w for the last 20 sec of flight. The heat pipe condenser was mounted into an aluminum heat sink which was cooled to 103 K at launch and increased in temperature to 128 K by the end of the flight. Ground test data obtained for the flight heat pipe, together with theoretical predictions, indicate a zero-g heat transport capability of 3500 to 4000 w-cm in the 100-125 K temperature range.

Harwell, W.

Orbiting Astronomical Observatory heat pipe flight performance data.

The paper describes preflight and inflight performance checkout of the three isothermalizer heat pipes onboard the OAO-C spacecraft. The three pipes are: an axially grooved pipe, a pedestal artery pipe, and a self-priming spiral artery pipe. All pipes are 1/2-inch diameter tube rolled into a 48-inch diameter hoop. They are constructed of aluminum and use ammonia as working fluid. Periodic inflight performance checks have been made since launch in August 1972. No degradation in performance of any of the pipes has been detected. The flight data are in excellent agreement with ground test data.

Harwell, W.