Engineering Papers⌕ Search

Engineering topics

Hartle, R. E.

Publications and source records attributed to Hartle, R. E..

At least 73 records · Page 4

Observed composition of the ionosphere of Venus - Implications for the ionization peak and the maintenance of the nightside ionosphere

Across the nightside of Venus, daily measurements from the PV Orbiter Ion Mass Spectrometer often indicate an ionosphere of relatively abundant concentration, with a composition characteristic of the dayside ionosphere. Such conditions are interspersed by other days on which the ionosphere appears to largely 'disappear' down to about 200 km, with ion concentrations at lower heights also much reduced. These characteristics, coupled with observations of strong day to night flows of O(+) in the upper ionosphere, support arguments that ion transport from the dayside is important for the maintenance of the nightside ionosphere. In the range 140-160 km, strong concentrations of O2(+) and NO(+) indicate that the ionization peak is at times composed of at least two prominent ion species. Nightside concentrations of O2(+) and NO(+) as large as 100,000 and 10,000/cu cm, respectively, appear to require sources in addition to that provided by transport. The most probable sources are considered briefly, and no satisfactory explanation is yet found for the observed NO(+) concentrations.

Taylor, H. A., Jr.↗

Titan's ion exosphere observed from Voyager 1

The plasma wake surrounding Titan in Saturn's rotating magnetosphere is characterized by a plasma which is denser and cooler than the surrounding subsonic magnetospheric plasma, and which is produced by the deflection of magnetospheric plasma around Titan and the addition of exospheric ions picked up by the rotating magnetosphere. A resemblance to the interaction between the solar wind and Venus is shown for the case of ion pickup in the ion exosphere outside Titan's magnetic tail and ion flow within the boundaries of the tail as Saturn's rotating magnetosphere interacts with Titan. The boundary of the tail is indicated by a sharp reduction in the flux of high-energy electrons, which are removed by inelastic scattering with the atmosphere and centrifugal drift produced when the electrons traverse the magnetic field draped around Saturn.

Hartle, R. E.↗

Plasma observations near Saturn - Initial results from Voyager 2

Results of plasma measurements made by Voyager 2 in the vicinity of Saturn are discussed and compared with those made by Pioneer 11 and Voyager 1 in a more limited range of latitudes. The initial bow shock crossing on the inbound trajectory closely agreed with the shock position inferred from the external ram pressure in the solar wind, although boundaries on the outbound pass were much further out than expected. Magnetospheric plasma observations reveal the presence of (1) shocked solar wind plasma in the magnetosheath between 30 and 22 Saturn radii; (2) a variable density region between 17 Saturn radii and the magnetopause; (3) an extended thick plasma sheet between 17 and 7 Saturn radii; and (4) an inner plasma torus probably originating from local sources. The ratio of heavy to light ions was observed to vary with distance to the equatorial plane in the dayside magnetosphere, with the heavy ions, probably O(+), more closely confined to the equatorial plane. The plasma data also account for the observed inner boundary of the neutral hydrogen torus discovered by Voyager 1.

Bridge, H. S.↗

Effects of large-scale magnetic fields in the Venus ionosphere

Theoretical models of the ionosphere of Venus have been constructed in the past without due consideration of the fact that the ionosphere is sometimes magnetized. This paper examines some differences between the magnetized and unmagnetized dayside Venus ionosphere using the Pioneer Venus Orbiter Langmuir probe and magnetometer data. Particular attention is given to the evaluation of the altitude profiles of the thermal electron heating and comparison of the magnitude of the magnetic force with other forces in the ionosphere. Several examples illustrate how heating profiles are different in the magnetized ionosphere with effective heating below 200 km altitude reduced by orders of magnitude compared to the field-free ionosphere. The force associated with the magnetic field is comparable to other forces in the magnetized ionosphere. The measured plasma density, electron temperature and magnetic field thus suggest that large-scale magnetic fields should be included in future ionosphere models.

Luhmann, J. G.↗

Modulation of dayside on and neutral distributions at Venus Evidence of direct and indirect solar energy inputs

The details of solar variability and its coupled effects on the Venusian dayside are examined for evidence of short-term perturbations and associated energy inputs. Ion and neutral measurements obtained from the Orbiter Ion Mass Spectrometer and Orbital Neutral mass Spectrometer are used to show that the dayside concentrations of CO2(+) and the neutral gas temperature are smoothly modulated with a 28-day cycle reasonably matching that of the solar F(10.7) and EUV fluxes. Earlier measurements show less pronounced and more irregular modulations and more conspicuous short-term day-to-day fluctuations in the ions and neutrals, as well as relatively large enhancements in the solar wind, which appear consistent with differences in solar coronal behavior during the two periods. It is suggested that the solar wind variations cause fluctuations in joule heating, producing the observed short-term ion and neutral variations.

Taylor, H. A., Jr.↗

Plasma observations near Saturn - Initial results from Voyager 1

The Voyager 1 encounter with Saturn and its satellites yielded extensive measurements of magnetospheric low-energy plasma electrons and positive ions, both heavy and light, probably of hydrogen and nitrogen or oxygen. At radial distances between 15 and 7 Saturn radii on the inbound trajectory, the plasma appears to corotate with a velocity within 20% of that theoretically expected for rigid corotation. The Titan data, taken while the moon was inside the Saturn magnetosphere, shows a clear signature characteristic of the interaction between a subsonic corotating magnetospheric plasma and the atmospheric or ionospheric exosphere of Titan.

Bridge, H. S.↗

Dynamic variations observed in thermal and superthermal ion distributions in the dayside ionosphere of Venus

In-situ measurements of the ion composition and concentration of the ionosphere of Venus are obtained with the Bennett RF ion mass spectrometer (OIMS) on the Pioneer Venus Orbiter (PVO). Dayside ion profiles exhibit considerable variability in the height of the ionopause as well as the scale heights of the ion constituents, which reflect the compression and expansion of the ionosphere in response to solar wind variations. Near the dayside upper boundary of the thermal O+ distribution, super-thermal ions are detected by the OIMS, presenting a complication for identifying the ion signature of the ionopause. Correlated with the presence of the superthermal ions, the ac electric field detector (OEFD) detects regions of intensified signals, with peak response in the 100 Hz frequency channel. It is expected that further analysis of the superthermal ion-electric field signatures will contribute to a clearer understanding of the physical processes underlying the formation of the ionopause.

Taylor, H. A., Jr.↗

Temporal and spatial variations observed in the ionospheric composition of Venus - Implication for empirical modelling

The distributions of several ion species in a data base obtained by in situ measurements of the thermal ion composition of the ionosphere of Venus by the Pioneer Venus Orbiter have been sorted to identify temporal and spatial variations and determine the feasibility of an analytical representation of the experimental results. The first results from the sorting of several prominent ions including O(+), O2(+), and H(+) and several minor ions including CO2(+), C(+), and H2(+) reveal significant diurnal variations which consist of strong day to night contrast in the ion concentrations, with differences of one to two orders of magnitude, depending upon ion mass and altitude. It is suggested that repeatable day to night gradients in the ion distribution are adaptable to parametric modeling.

Taylor, H. A., Jr.↗

Dynamical response of the dayside ionosphere of Venus to the solar wind

Dayside ion composition measurements made by the orbiter ion mass spectrometer and the orbiter electron temperature probe on the Pioneer Venus orbiter are used to infer the dominant processes involved in the dynamic response of the Venus ionosphere to the solar wind. The analysis is confined to the topside ionosphere in the vicinity of the subsolar point, where the ionosphere-solar wind interaction is expected to be maximized. Height profiles of the ion composition and plasma temperatures in the main body of the topside ionosphere, lying between the ionopause and chemical equilibrium regions, reveal that the ionosphere is in a compressed state. This region of the ionosphere is interpreted in terms of a stationary equilibrium where the compression is derived from the ponderomotive force j x B. The estimated magnitude of this force is confirmed by the magnetic field measurements made by the orbiter magnetometer.

Hartle, R. E.↗

Global observations of the composition and dynamics of the ionosphere of Venus - Implications for the solar wind interaction

The in-situ measurements of the global composition and Venus ionosphere dynamics recorded by the Bennett ion mass spectrometer on the Pioneer Venus orbiter during Dec. 1978-Aug. 1979 are presented. The observations of three plasma regimes show the bowshock-ionosheath region, the thermal ionosphere, and a superthermal flowing ion layer contacting the ionosphere at the ionopause and extending outward to different heights above the planet. An abundant ionosphere dominated by O(+) above 200 km and by O2(+) down to the typical periapsis altitudes of 160 km occur during quiet periods; less disturbed data shows strong day to night changes in the distributions of ions including O(+), O2(+), CO2(+), and N(+). The ionopause is located near the subpolar point at 250-400 km; under disturbed nighttime conditions it may have randomly spaced concentration gradients in the dusk region.

Taylor, H. A., Jr.↗

Dynamic properties of the thermosphere inferred from Pioneer Venus mass spectrometer measurements

The data obtained by the Pioneer Venus spectrometer experiments indicate that the day-night temperature contrast on Venus is associated with wind velocities of about 200 m/s which transport oxygen, helium, and hydrogen toward the night side. A mass exchange with the mesosphere commensurate with an eddy diffusion coefficient of 3 x 10 to the 7th is required to buffer the horizontal advection so as to reproduce the observed day time bulge in oxygen and the small diurnal variations in helium. The observed time response and magnitude of the day-night density variations require transport processes to be effective over time periods between five and ten days, implying a superrotation rate or prevailing winds in excess of 50 m/s at the equator. Nonlinear mass transport results in wave steepening and contributes to the amplification of the density extrema in hydrogen and helium.

Mayr, H. G.↗

Pioneer Venus Orbiter neutral gas mass spectrometer experiment

The Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) is designed to measure the vertical and horizontal density variations of the major neutral constituents in the upper atmosphere of Venus. The mass spectrometer sensor includes a retarding potential ion source, hyperbolic quadrupole rod analyzer, and electron multiplier detector. The supporting electronic system consists of hybrid integrated circuits to reduce weight and power. The ONMS instrument was launched aboard the Pioneer Venus Orbiter on May 20, 1978, and turned on in orbit around Venus on December 4, 1978. It has operated flawlessly for over a Venus year (243 earth days) and has returned data of the composition of the major constituents in the Venus atmosphere between the altitudes of 150 and 350 km.

Niemann, H. B.↗

Venus upper atmosphere neutral gas composition - First observations of the diurnal variations

Measurements of the composition, temperature, and diurnal variations of the major neutral constituents in the thermosphere of Venus are being made with a quadrupole mass spectrometer on the Pioneer Venus Orbiter. Concentrations of carbon dioxide, carbon monoxide, molecular nitrogen, atomic oxygen, and helium are presented, in addition to an empirical model of the data. The concentrations of the heavy gases, carbon dioxide, carbon monoxide, and molecular nitrogen, rapidly decrease from the evening terminator toward the nightside; the concentration of atomic oxygen remains nearly constant and the helium concentration increases, an indication of a nightside bulge. The kinetic temperature inferred from scale heights drops rapidly from 230 K at the terminator to 130 K at a solar zenith angle of 120 deg, and to 112 K at the antisolar point.

Niemann, H. B.↗

Ionosphere of Venus - First observations of day-night variations of the ion composition

Preliminary observations of day-night variations in the ion composition of the ionosphere of Venus, obtained by the Pioneer Venus Orbiter ion mass spectrometer experiment, are reported. A remarkable abundance and extent of ionization in the deep regions of the nightside ionosphere was observed, in spite of the long Venus night. A comparison of dayside and nightside ion distributions reveals a nightside composition similar in several respects to that of the dayside, with the ions O(+) and O2(+) forming the nightside F 2 and F 1 regions, respectively, as in the dayside. Important differences include a greater abundance of low-latitude ionization in the nightside, a significant increase of H(+) and NO(+) ions with increasing solar zenith angle, and extreme dynamic variability of the nightside region above 160 km. Ion composition data support the view that the nightside ionosphere can be maintained by the transport of ionization from the dayside.

Taylor, H. A., Jr.↗

Venus ionosphere - Photochemical and thermal diffusion control of ion composition

The major photochemical sources and sinks for ten of the ions measured by the ion mass spectrometer on the Pioneer Venus bus and orbiter spacecraft that are consistent with the neutral gas composition measured on the same spacecraft are identified. The neutral gas temperature (as a function of solar zenith angle) derived from measured ion distributions in photochemical equilibrium is given. Above 200 kilometers, the altitude behavior of ions is generally controlled by plasma diffusion, with important modifications for minor ions due to thermal diffusion resulting from the observed gradients of plasma temperatures. The dayside equilibrium distributions of ions are sometimes perturbed by plasma convection, while lateral transport of ions from the dayside seems to be a major source of the nightside ionosphere.

Bauer, S. J.↗

Ionosphere of Venus - First observations of the dayside ion composition near dawn and dusk

Independent Bennett radio-frequency ion mass spectrometers on the Pioneer Venus bus and orbiter spacecraft obtained in situ measurements of the composition of the ionosphere of Venus. The spectrometer on the bus explored the dawn region while the spectrometer on the orbiter explored the duskside region. Information on the ion composition in the topside, the lower ionosphere, and the upper ionosphere is presented. Below the O(+) peak near 200 km, the ions are found to exhibit scale heights consistent with a neutral gas temperature of about 180 K near the terminator. In the upper ionosphere, scale heights of all species reflect the effects of plasma transport.

Taylor, H. A., Jr.↗

Ionosphere of Venus - First observations of the effects of dynamics on the dayside ion composition

Data obtained by Bennett radio-frequency ion mass spectrometers indicate that the ionosphere envelope, dominated above 200 km by O(+), responds dramatically to variations in the solar wind pressure. The pressure compresses the thermal ion distributions from heights as great as 1800 km inward to 280 km. At the thermal ion boundary, or ionopause, the ambient ions are swept away by the solar wind, while at higher altitudes energetic ion currents are detected. Within the ionosphere, ion convection stimulated by the solar wind interaction causes pass-to-pass differences in the ion scale heights.

Taylor, H. A., Jr.↗

Venus upper atmosphere neutral composition - Preliminary results from the Pioneer Venus orbiter

Measurements in situ of the neutral composition and temperature of the thermosphere of Venus are being made with a quadrupole mass spectrometer on the Pioneer Venus orbiter. The presence of many gases, including the major constituents CO2, CO, N2, O, and He has been confirmed. Carbon dioxide is the most abundant constituent at altitudes below about 155 kilometers in the terminator region. Above this altitude atomic oxygen is the major constituent, with O/CO2 ratios in the upper atmosphere being greater than was commonly expected. Isotope ratios of O and C are close to terrestrial values. The temperature inferred from scale heights above 180 kilometers is about 400 K on the dayside near the evening terminator at a solar zenith angle of about 69 deg. It decreases to about 230 K when the solar zenith angle is about 90 deg.

Niemann, H. B.↗