Engineering PapersSearch

Engineering topics

Harrison, R. G.

Publications and source records attributed to Harrison, R. G..

Applications of Electrified Dust and Dust Devil Electrodynamics to Martian Atmospheric Electricity

Atmospheric transport and suspension of dust frequently brings electrification, which may be substantial. Electric fields of 10 kV m(exp. -1) to 100 kV m(exp. -1) have been observed at the surface beneath suspended dust in the terrestrial atmosphere, and some electrification has been observed to persist in dust at levels to 5 km, as well as in volcanic plumes. The interaction between individual particles which causes the electrification is incompletely understood, and multiple processes are thought to be acting. A variation in particle charge with particle size, and the effect of gravitational separation explains to, some extent, the charge structures observed in terrestrial dust storms. More extensive flow-based modelling demonstrates that bulk electric fields in excess of 10 kV m(exp. -1) can be obtained rapidly (in less than 10 s) from rotating dust systems (dust devils) and that terrestrial breakdown fields can be obtained. Modelled profiles of electrical conductivity in the Martian atmosphere suggest the possibility of dust electrification, and dust devils have been suggested as a mechanism of charge separation able to maintain current flow between one region of the atmosphere and another, through a global circuit. Fundamental new understanding of Martian atmospheric electricity will result from the ExoMars mission, which carries the DREAMS (Dust characterization, Risk Assessment, and Environment Analyser on the Martian Surface) MicroARES (Atmospheric Radiation and Electricity Sensor) Instrumentation to Mars in 2016 for the first in situ electrical measurements.

Lighting Discharge

Programmable temperature control system for biological materials

A system was constructed which allows programmable temperature-time control for a 5 cu cm sample volume of arbitrary biological material. The system also measures the parameters necessary for the determination of the sample volume specific heat and thermal conductivity as a function of temperature, and provides a detailed measurement of the temperature during phase change and a means of calculating the heat of the phase change. Steady-state and dynamic temperature control is obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container is totally immersed into a cold heat sink. Using a mixture of dry ice and alcohol at 79 C, the sample volume can be controlled from +40 to -60 C at rates from steady state to + or - 65 C/min. Steady-state temperature precision is better than 0.2 C, while the dynamic capability depends on the temperature rate of change as well as the mass of both the sample and the container.

Anselmo, V. J.

Latest rocket measurements of the solar constant

Three rocket flights which carried a payload of absolute radiometers to measure the solar constant with an accuracy of plus or minus 0.5 per cent have been accomplished. Several of the rocket radiometers were duplicates of those aboard the Solar Maximum Mission and Nimbus spacecrafts. The values for the solar constant obtained by the rocket sensors for the three flight dates indicate an increase between the first and latter two flights approximately equivalent to the uncertainty of the measurements. The values for the solar constant for the three flights are 1367, 1372 and 1374 W/sq m.

Duncan, C. H.

A controlled rate freeze/thaw system for cryopreservation of biological materials

A system which allows programmable temperature-time control for a 5 cc sample volume of an arbitrary biological material was constructed. Steady state and dynamic temperature control was obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container was totally immersed into a cold heat sink. Sample volume thermodynamic property data were obtained by measurements of heater power and heat flux through the container walls. Using a mixture of dry ice and alcohol at -79 C, sample volume was controlled from +40 C to -60 C at rates from steady state to + or - 65 C/min. Steady state temperature precision was better than 0.2 C while the dynamic capability depends on the temperature rate of change as well as the thermal mass of the sample and the container.

Anselmo, V. J.

Rocket calibration of the Nimbus 6 solar constant measurements

A sounding rocket experiment was performed in June 1976, in which the solar constant was observed simultaneously outside the earth's atmosphere by three types of absolute cavity radiometers (the Primary Absolute Cavity Radiometer and two Active Cavity Radiometers, Type IV) and duplicates of Nimbus 6 ERB/ESP (Earth Radiation Budget/Eclectic Satellite Pyrheliometer) solar channels. The preliminary average solar constant result from the cavity radiometers is 1367 W/sq m with an uncertainty of less than plus or minus 0.5% in SI units. The duplicate ERB channel 3 on the rocket gave a value of 1389 W/sq m, which agreed exactly with the Nimbus 6 ERB channel 3 measurement made simultaneously with the rocket flight.

Duncan, C. H.

Rocket calibration of the Nimbus 6 solar constant measurements

Total solar irradiance was observed simultaneously outside the earth's atmosphere by three types of absolute cavity radiometers and duplicates of four of the Nimbus 6 Earth Radiation Budget (ERB) solar channels in a June 1976 sounding rocket experiment. The preliminary average solar constant result from the cavity radiometers is 1367 Wm (-2) with an uncertainty of less than + or - 0.5% in S.I. units. The duplicate ERB channel 3 on the rocket gave a value of 1389 Wm (-2) which agreed exactly with the Nimbus 6 ERB channel 3 measurement made simultaneously with the rocket flight.

Duncan, C. H.

Miniature capacitor functions as pressure sensor

Miniature capacitor operates as a differential pressure telemetry sensor during free flight of test model in a hypersonic wind tunnel. The capacitor incorporates a beryllium copper diaphragm. It is also used as an absolute pressure sensor.

Harrison, R. G.