Engineering PapersSearch

Engineering topics

Harkness, J. D.

Publications and source records attributed to Harkness, J. D..

At least 19 records

Evaluation program for secondary spacecraft cells. Initial evaluation tests of General Electric Company 4.0 ampere-hour nickel-cadmium spacecraft cells for the AMPTE satellite program

Cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test are addressed. The Active Magnetic Particle Tracer Explorer (AMPTE) cell design was characterized and the effects of specific mission parameters on cell life were demonstrated.

Harkness, J. D.

Results of continuous synchronous orbit testing of sealed nickel-cadmium cells

Test results from continuous synchronous orbit testing of sealed nickel cadmium cells are presented. The synchronous orbit regime simulates a space satellite maintaining a position over a fixed point on earth as the earth rotates on its axis and revolves about the sun. Characteristics of each lot of cells, test conditions, and charge control methods are described.

Harkness, J. D.

Evaluation program for secondary spacecraft cells: Seventeenth annual report of cycle life test

Acceptance tests were conducted on nickel cadmium, silver cadmium, and silver zinc cells to insure that all cells put into the life cycle program meet the specifications outlined in the respective purchase contracts. Statistical information is presented on cell performance characteristics and limitations. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of space batteries. Battery weaknesses encountered in satellite programs such as IMP, NIMBUS, OGO, OAO, SAS, and TETR were studied and remedied through special tests.

Harkness, J. D.

Evaluation Program for Secondary Spacecraft Cells: Initial Evaluation Tests of General Electric Company 6.0 Ampere Hour Nickel Cadmium Spacecraft Cells for the Dynamic Explorer Satellite Program

Evaluation tests of 10 nickel cadmium cells are described. Although pressures were greater than what normally was exhibited by General Electric cells in the past, it is recommended that these cells be placed on life test simulating the predicted Dynamic Explorer flight profiles.

Harkness, J. D.

Cycle life test of secondary spacecraft cells

The results of the life cycling program on rechargeable calls are reported. Information on required data, the use of which the data will be put, application details, including orbital description, charge control methods, load rquirements, etc., are given. Cycle tests were performed on 660 sealed, nickel cadmium cells. The cells consisted of seven sample classifications ranging form 3.0 to 20 amp. hours. Nickel cadmium, silver cadmium, and silver zinc sealed cells, excluding synchronous orbit and accelerated test packs were added. The capacities of the nickel cadmium cells, the silver cadmium and the silver zinc cells differed in range of amp hrs. The cells were cylced under different load, charge control, and temperature conditions. All cell packs are recharged by use of a pack voltage limit. All charging is constant current until the voltage limit is reached.

Harkness, J. D.

Initial Evaluation tests of 20.0 amphere-hour sealed nickel-cadmium cells manufactured for NASA's standard cell program

Evaluation tests of 116 nickel cadmium cells provided by four manufacturers are described. Each manufacturer's group of cells, on the average, indicated an increase in plate stack thickness following the test. No limits or requirements were exceeded by any of the cells manufactured by General Electric. Limits/requirements exceeded during the charge portion of the testing are given.

Harkness, J. D.

Initial evaluation tests of General Electric Company 12.0 ampere hour nickel cadmium spacecraft cells with design variables

All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.

Harkness, J. D.

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company, 6.0 ampere-hour nickel-cadmium spacecraft cells for the GOES-D, E and F satellite program

The tests are to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are referenced to normally expected values based on past performance of aerospace nickel-cadmium cells with demonstrated life characteristics. Recommendations for the improvement of the manufacturing processes are presented.

Harkness, J. D.

Evaluation program for secondary spacecraft cells: Cycle life test

The service life and storage stability for several storage batteries were determined. The batteries included silver-zinc batteries, nickel-cadmium batteries, and silver-cadmium batteries. The cell performance characteristics and limitations are to be used by spacecraft power systems planners and designers. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is presented.

Harkness, J. D.

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere-hour nickel-cadmium spacecraft cells for the tracking data relay satellite system

Five cells provided by NASA's Goddard Space Flight Center were evaluated at room temperature and pressure (25 C plus or minus 2 C) with discharges at the 2 hour rate. Measurements of the cell containers following test, indicated an average increase of .006 inches at the plate thickness. Average end of charge voltages and pressures, and capacity output in ampere hours were determined. Three cells exceeded the voltage requirements of 1.52 volts during both c/10 charges at 20 C. All cells exceeded the voltage requirement of 1.52 volts during the 0 C overcharge test, although their end charges were below 1.50 volts. The pressure requirement of 65 psia was exceeded by both pressure transducer cells during c/10 charges at 25 C and 20 C and also during the 0 C overcharge test. The cells with pressure transducers reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test, and exhibited a pressure decay of 2 psia during the last 30 minutes of the 1 hour open circuit stand. Average capacity was 51.3 ampere hours.

Harkness, J. D.

Evaluation program for secondary spacecraft cells

The results of life cycle tests of secondary spacecraft cells are summarized. Cells consisted of seven sample classifications ranging from 3.0 to 20 ampere-hours, 1326 nlc nickel cadmium, 183 silver cadmium, and 125 silver zinc sealed cells. Variables examined include load, charge control, and temperature conditions.

Harkness, J. D.

Initial evaluation tests of Eagle-Picher Industries 9.0 ampere-hour nickel-cadmium spacecraft cells for the heat capacity mapping mission satellite and the stratospheric aerosol and gas experiment satellite

The results of tests to insure that all cells put into the life cycle program are of high quality are reported. The tests consisted of the following: phenolptalein leak tests, internal short test, charge efficiency test, and overcharge tests. The results of tests for 10 cells are tabulated.

Harkness, J. D.

Initial evaluation tests of General Electric Company 26.5 ampere-hour nickel-cadmium spacecraft cells with auxiliary electrodes for the TIROS-N and NOAA-A satellites

This evaluation test program had the purpose to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are referenced to as normally expected values based on past performance of aerospace nickel-cadmium cells with demonstrated life characteristics. A requirement does not constitute a limit for discontinuance from test.

Harkness, J. D.

Evaluation Program for Secondary Spacecraft Cells: Synchronous Orbit Testing of Sealed Nickel Cadmium Cells

Performance data concerning sealed nickel-cadmium cells operating under a synchronous orbit regime are presented. A space satellite maintaining a position over a fixed point on earth as the earth rotates on its axis and revolves about the sun was simulated. Results include: (1) exposure to synchronous orbit testing at a temperature of 40 C yields less than 6 years of life; (2) performance at -20 C presents a low capacity problem; (3) the capacity check, performed at the middle of each show period, provides a temporary red reconditioning effect on the cells in that the end-of-discharge voltages are higher, for approximately 7 to 10 days, following the capacity check than they were 7 to 10 days prior to the capacity check; (4) all the test packs at -20 C and 40 C have either failed or were discontinued because of low capacity; and (5) test packs at temperatures of 0 C and 10 C have delivered the best capacity during life and packs tested at 20 C showed better life capability than packs tested at -20 C and 40 C.

Harkness, J. D.