Pulsed Phase Lock Loop Device for Monitoring Intracranial Pressure During Space Flight

We have developed an ultrasonic device to monitor ICP waveforms non-invasively from cranial diameter oscillations using a NASA-developed pulsed phase lock loop (PPLL) technique. The purpose of this study was to attempt to validate the PPLL device for reliable recordings of ICP waveforms and analysis of ICP dynamics in vivo. METHODS: PPLL outputs were recorded in patients during invasive ICP monitoring at UCSD Medical Center (n=10). RESULTS: An averaged linear regression coefficient between ICP and PPLL waveform data during one cardiac cycle in all patients is 0.88 +/- 0.02 (mean +/- SE). Coherence function analysis indicated that ICP and PPLL waveforms have high correlation in the lst, 2nd, and 3rd harmonic waves associated with a cardiac cycle. CONCLUSIONS: PPLL outputs represent ICP waveforms in both frequency and time domains. PPLL technology enables in vivo evaluation of ICP dynamics non-invasively, and can acquire continuous ICP waveforms during spaceflight because of compactness and non-invasive nature.

Ueno, Toshiaki↗

Lumbar spine disc heights and curvature: upright posture vs. supine compression harness

INTRODUCTION: Spinal lengthening in microgravity is thought to cause back pain in astronauts. A spinal compression harness can compress the spine to eliminate lengthening but the loading condition with harness is different than physiologic conditions. Our purpose was to compare the effect of spine compression with a harness in supine position on disk height and spinal curvature in the lumbar spine to that of upright position as measured using a vertically open magnetic resonance imaging system. METHODS: Fifteen healthy subjects volunteered. On day 1, each subject lay supine for an hour and a baseline scan of the lumbar spine was performed. After applying a load of fifty percent of body weight with the harness for thirty minutes, the lumbar spine was scanned again. On day 2, after a baseline scan, a follow up scan was performed after kneeling for thirty minutes within the gap between two vertically oriented magnetic coils. Anterior and posterior disk heights, posterior disk bulging, and spinal curvature were measured from the baseline and follow up scans. RESULTS: Anterior disk heights increased and posterior disk heights decreased compared with baseline scans both after spinal compression with harness and upright posture. The spinal curvature increased by both loading conditions of the spine. DISCUSSION: The spinal compression with specially designed harness has the same effect as the physiologic loading of the spine in the kneeling upright position. The harness shows some promise as a tool to increase the diagnostic capabilities of a conventional MR system.

Non-NASA Center↗

Compression under a mechanical counter pressure space suit glove

Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

NASA Discipline Life Sciences Technologies↗

Skin microvascular flow during hypobaric exposure with and without a mechanical counter-pressure space suit glove

INTRODUCTION: Current space suits are rigid, gas-pressurized shells that protect astronauts from the vacuum of space. A tight elastic garment or mechanical-counter-pressure (MCP) suit generates pressure by compression and may have several advantages over current space suit technology. In this study, we investigated local microcirculatory effects produced with and without a prototype MCP glove. METHODS: The right hand of eight normal volunteers was studied at normal ambient pressure and during exposure to -50, -100 and -150 mm Hg with and without the MCP glove. Measurements included the pressure against the hand, skin microvascular flow, temperature on the dorsum of the hand, and middle finger girth. RESULTS: Without the glove, skin microvascular flow and finger girth significantly increased with negative pressure, and the skin temperature decreased compared with the control condition. The MCP glove generated approximately 200 mm Hg at the skin surface; all measured values remained at control levels during exposure to negative pressure. DISCUSSION: Without the glove, skin microvascular flow and finger girth increased with negative pressure, probably due to a blood shift toward the hand. The elastic compression of the material of the MCP glove generated pressure on the hand similar to that in current gas-pressurized space suit gloves. The MCP glove prevented the apparent blood shift and thus maintained baseline values of the measured variables despite exposure of the hand to negative pressure.

NASA Discipline Cardiopulmonary↗

Lower-body negative-pressure exercise and bed-rest-mediated orthostatic intolerance

PURPOSE: Supine, moderate exercise is ineffective in maintaining orthostatic tolerance after bed rest (BR). Our purpose was to test the hypothesis that adding an orthostatic stress during exercise would maintain orthostatic function after BR. METHODS: Seven healthy men completed duplicate 15-d 6 degrees head-down tilt BR using a crossover design. During one BR, subjects did not exercise (CON). During another BR, subjects exercised for 40 min.d(-1) on a supine treadmill against 50-60 mm Hg LBNP (EX). Exercise training consisted of an interval exercise protocol of 2- to 3-min intervals alternating between 41 and 65% (.)VO(2max). Before and after BR, an LBNP tolerance test was performed in which the LBNP chamber was decompressed in 10-mm Hg stages every 3 min until presyncope. RESULTS: LBNP tolerance, as assessed by the cumulative stress index (CSI) decreased after BR in both the CON (830 +/- 144, pre-BR vs 524 +/- 56 mm Hg.min, post-BR) and the EX (949 +/- 118 pre-BR vs 560 +/- 44 mm Hg.min, post-BR) conditions. However, subtolerance (0 to -50 mm Hg LBNP) heart rates were lower and systolic blood pressures were better maintained after BR in the EX condition compared with CON. CONCLUSION: Moderate exercise performed against LBNP simulating an upright 1-g environment failed to protect orthostatic tolerance after 15 d of BR.

NASA Center JSC↗

The Gravity of LBNP Exercise: Lessons Learned from Identical Twins in Bed for 30 Days

Microgravity leads to cardiovascular deconditioning in humans, which is manifested by post-flight reduction of orthostatic tolerance and upright exercise capacity. During upright posture on Earth, blood pressures are greater in the feet than at heart or head levels due to gravity's effects on columns of blood in the body. During exposure to Microgravity, all gravitational blood pressures disappear. Presently, there is no exercise hardware available for space flight to provide gravitational blood pressures to tissues of the lower body. We hypothesized that 40 minutes of supine treadmill running per day in a LBNP chamber at 1.0 to 1.2 body weight (approximately 50 - 60 mm Hg LBNP) with a 5 min resting, nonexercise LBNP exposure at 50 mm Hg after the exercise session will maintain aerobic fitness orthostatic tolerance, and selected parameters of musculoskeletal function during 30 days of bed rest (simulated microgravity). This paper is an interim report of some of our findings on 16 subjects.

Hargens, Alan R.↗

Cutaneous Microvascular Flow In the Foot During Simulated Variable Gravities

Our objective was to elucidate how varying gravitational fields affect blood perfusion in the sole of the foot. Human subjects underwent whole-body tilting at four angles: upright (1 G(sub z), 22 deg (.38 G(sub z)), 10 deg (.17 G(sub z)), and supine (0 G(sub z)), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight bearing load was measured beneath the same foot with a calibrated scale. Foot mean arterial pressures (MAP) were calculated by adding estimated hydrostatic pressures to continuously recorded heart-level blood pressures for each subject. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of one kilogram beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load (CL). Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load, OL). CL and OL were normalized to each subject's body weight and expressed as percent of body weight. Mean CLs (SD in parentheses) for simulated Earth, Mars, Moon, and micro-gravities were 14 (5), 8 (2), 6 (2), and 5 (2) percent of body weight, respectively. OLs were 12 (3), 6 (1), 5 (2), and 4 (1), respectively. Calculated foot MAPs for each simulated gravitational field were 192 (19), 127 (12), 106 (10), and 87 (9) mm Hg, respectively. CL and OL were significantly correlated with foot MAP (r = 0.70, 0.72, respectively). Overall, CL and OL were significantly different (p is less than 0.001). The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischernia during loading in microgravity than on Earth.

Chang, David S.↗

Physiologic Pressure and Flow Changes During Parabolic Flight (Pilot Study)

The objective of this study was to obtain measurement of cutaneous tissue perfusion central and peripheral venous pressure, and esophageal and abdominal pressure in human test subjects during parabolic flight. Hemodynamic data recorded during SLS-I and SLS-2 missions have resulted in the paradoxical finding of increased cardiac stroke volume in the presence of a decreased central venous pressure (CVP) following entry in weightlessness. The investigators have proposed that in the absence of gravity, acceleration-induced peripheral vascular compression is relieved, increasing peripheral vascular capacity and flow while reducing central and peripheral venous pressure, This pilot study seeks to measure blood pressure and flow in human test subjects during parabolic flight for different postures.

Pantalos, George↗

Noninvasive Intracranial Volume and Pressure Measurements Using Ultrasound (Head and Spinal)

Prevention of secondary brain injuries following head trauma can be accomplished most easily when intracranial pressure (ICP) is monitored. However, current measurement techniques are invasive and thus not practical in the combat environment. The Pulsed Phase Lock Loop device, which was developed and patented by consultants Drs. Yost and Cantrell, uses a unique, noninvasive ultrasonic phase comparison method to measure slight changes in cranial volume which occur with changes in ICP. Year two studies included whole body head-up and head-down tilting effects on intracranial compliance and pressure in six healthy volunteers.

Hargens, Alan R.↗

Gravity of Living Systems: May the Force Be With You

Gravity, the force which shapes the architecture of organisms from single cells to dinosaurs, has been the most constant environmental factor during the evolution of species on Earth. With long-duration space flight, an understanding of how gravity affects living systems gains greater urgency in order to maintain the health and performance of crews who will explore the solar system. For example, the cardiovascular and musculoskeletal systems are normally exposed to gravitational gradients of blood pressure and weight on Earth. Such gradients increase blood pressure and tissue weight in dependent tissues of the body. Thus, from a physiologic standpoint, these systems are greatly affected by altered gravity. Exposure to actual and simulated microgravity causes blood and tissue fluid to shift from the legs to the head. Studies of humans in space have documented facial edema, space adaptation syndrome, decreased plasma volume, muscle atrophy, and loss of bone strength. Return of astronauts to Earth is accompanied by orthostatic intolerance, decreased neuromuscular coordination, and reduced exercise capacity. These factors decrease performance during descent from orbit and increase risk during emergency egress from the space craft. Models of simulated microgravity include 60 head-down tilt, immersion, and prolonged horizontal bedrest. Head-down tilt and dry immersion are the most accepted models and studies using these models of up to one year have been performed in Russia. Sensitive animal models which offer clear insights into the role of gravity on structure and function include the developing giraffe and snakes from various habitats. Finally, possible countermeasures to speed readaptation of astronauts to gravity after prolonged space flight include exercise, lower body negative pressure, and centrifugation.

Hargens, Alan R.↗

MRI Evaluation of Spinal Length and Vertebral Body Angle During Loading with a Spinal Compression Harness

Weight bearing by the spinal column during upright posture often plays a role in the common problem of low back pain. Therefore, we developed a non-ferromagnetic spinal compression harness to enable MRI investigations of the spinal column during axial loading. Human subjects were fitted with a Nest and a footplate which were connected by adjustable straps to an analog load cell. MRI scans of human subjects (5 males and 1 female with age range of 27-53 yrs) during loaded and unloaded conditions were accomplished with a 1.5 Tesla GE Signa scanner. Studies of two subjects undergoing sequentially increasing spinal loads revealed significant decreases (r(sup 2) = 0.852) in spinal length between T4 and L5 culminating in a 1.5 to 2% length decrease during loading with 75% body weight. Sagittal vertebral body angles of four subjects placed under a constant 50% body weight load for one hour demonstrated increased lordotic and kyphotic curvatures. In the lumbar spine, the L2 vertebral body experienced the greatest angular change (-3 deg. to -5 deg.) in most subjects while in the thoracic spine, T4 angles increased from the unloaded state by +2 deg. to +9 deg. Overall, our studies demonstrate: 1) a progressive, although surprisingly small, decrease in spinal length with increasing load and 2) relatively large changes in spinal column angulation with 50% body weight.

Campbell, James A.↗

Comparison of Upright Gait with Supine Bungee-Cord Gait

Running on a treadmill with bungee-cord resistance is currently used on the Russian space station MIR as a countermeasure for the loss of bone and muscular strength which occurs during spaceflight. However, it is unknown whether ground reaction force (GRF) at the feet using bungee-cord resistance is similar to that which occurs during upright walking and running on Earth. We hypothesized-that the DRAMs generated during upright walking and running are greater than the DRAMs generated during supine bungee-cord gait. Eleven healthy subjects walked (4.8 +/- 0.13 km/h, mean +/- SE) and ran (9.1 +/- 0.51 km/h) during upright and supine bungee-cord exercise on an active treadmill. Subjects exercised for 3 min in each condition using a resistance of 1 body weight calibrated during an initial, stationary standing position. Data were sampled at a frequency of 500Hz and the mean of 3 trials was analyzed for each condition. A repeated measures analysis of variance tested significance between the conditions. Peak DRAMs during upright walking were significantly greater (1084.9 +/- 111.4 N) than during supine bungee-cord walking (770.3 +/- 59.8 N; p less than 0.05). Peak GRFs were also significantly greater for upright running (1548.3 +/- 135.4 N) than for supine bungee-cord running (1099.5 +/- 158.46 N). Analysis of GRF curves indicated that forces decreased throughout the stance phase for bungee-cord gait but not during upright gait. These results indicate that bungee-cord exercise may not create sufficient loads at the feet to counteract the loss of bone and muscular strength that occurs during long-duration exposure to microgravity.

Boda, Wanda L.↗

Gait, Balance, Leg Strength, and Sprint Speed After Bedrest with LBNP Exercise

Microgravity and bedrest (BR) result in similar physiological decrements such as loss of muscle mass, muscle strength and balance. Previous studies analyzing exercise within lower body negative pressure (LBNP) have found that gait is similar in LBNP on a vertical treadmill and overground exercise on a horizontal treadmill. Since treadmill exercise is known to increase muscular strength and endurance, we tested the hypothesis that LBNP exercise on a vertical treadmill would prevent or attenuate many of the physical decrements which occur during bedrest. Based on our positive results from diverse tests of post-BR function, we believe that exercise within LBNP is worth pursuing as a countermeasure for reducing the physical deterioration that occurs during bedrest and microgravity.

Boda, Wanda L.↗

Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

Ueno, Toshiaki↗

Effect of Daily Supine LBNP Exercise on Gastrointestinal Motility During Antiorthostatic Bedrest in Normal Subjects

Space flight alters gastrointestinal (GI) function in general, and GI motility, in particular. This can decrease appetite, affect the body's ability to absorb nutrients, fluids and electrolytes, and contribute to a negative energy balance. Antiorthostatic bed rest (ABR) has been used to simulate microgravity-induced physiological changes in human subjects. The objective of this investigation is to determine if daily supine lower body negative pressure (LBNP) exercise will maintain GI motility at near normal levels during ABR. Eight subjects participated in the study protocol consisting of an ambulatory phase scheduled before bedrest periods and two 14 day bed rest (6 deg head-down tilt) periods, once with and another time without exercise. Supine treadmill running in an LBNP chamber was used for exercise. Mouth-to-cecum transit time (MCTT) of lactulose was measured indirectly using the rise in breath hydrogen level after oral administration of lactulose (20 g) following a standard low-fiber breakfast. GI motility during ambulatory and ABR periods was assessed using MCTT data. Results of this Study indicate that GI motility during ABR without exercise decreased by 45% [MCTT +/- S.E.M. 56.2 +/- 6.0 (Ambulatory); 87.3 +/- 8.3 (ABR)]. Supine LBNP exercise did not significantly alter this reduction in GI motility during ABR [MCTT +/- S.E.M. 81.3 +/- 4.2 (Exercise); 87.3 +/- 8.3 (No Exercise)]. These results suggest that supine LBNP exercise may not be an effective countermeasure for microgravity-induced decrements in GI motility and function.

Putcha, Lakshmi↗

Plasma Hormone Concentrations in Monkeys after Spaceflight

The aim of this study was to determine the effects of a 12.5 day spaceflight on the endocrine status of Rhesus monkeys. Male monkeys (three to four years old; 4 kg) were adapted to chair restraint and trained for 20 months. Blood samples were obtained from four control (C) and two flight (F) monkeys preflight (PF), post-flight (Recovery-R; days 0, 3, 11, and 17), and before and after a mission length simulation (S). Cortisol, T4, T3, testosterone (T), and IGF-1 were measured by RIA (radioimmunassay). Growth hormone (GH) was measured by an in vitro bioassay. Cortisol (16-34 ug/dl), T4 (3.9-7.4 ug/dl), and T (0.2-0.4 mg/ml) did not differ between F and C or between PF, R, and S samples. The low T values reflect the immaturity of the animals. In F, T3 fell from C levels of 208 +/- 4 ng/dl to 44 on R+0 and 150 on R+3, then returned to C. F showed a 55% decrease in GH at R+0 and decreases of 93, 89, and 80%, respectively, at R+3, 11, and 17. IGF-1 decreased from PF levels of 675 ng/ml to 365 (R+0) and 243 (R+3), but returned to C at R+11. GH and IGF-1 levels before and after S did not differ from each other or from C. The cause of the transitory decrease in T3 is unknown. The suppressed GH levels for 17 days after flight may reflect reduced proprioceptive input during flight. The faster recovery of IGF-1 suggests that factors other than reduced GH secretion are involved.

Grindeland, Richard E.↗

Forearm Muscle Oxygenation Decreases During Low Levels of Brief, Isometric Contraction

Regional muscle pain syndromes can be caused by repeated and sustained exertion of a specific muscle. Such exertion may elevate local tissue fluid pressure, reduce blood flow and tissue oxygenation (TO2), and cause fatigue, pain and functional deficits of the Involved muscle. Low levels (less than 20% maximum voluntary contraction (MVC)) of prolonged static contraction of the upper extremity are common In many occupational settings and May cause fatigue. The purpose of our Investigation was to determine whether TO2 decreases significantly at low levels of static contraction of the extensor carpi radialis brevis (ECRB).

Murthy Gita↗

Effects of Orientation on Recognition of Facial Affect

The ability to discriminate facial features is often degraded when the orientation of the face and/or the observer is altered. Previous studies have shown that gross distortions of facial features can go unrecognized when the image of the face is inverted, as exemplified by the 'Margaret Thatcher' effect. This study examines how quickly erect and supine observers can distinguish between smiling and frowning faces that are presented at various orientations. The effects of orientation are of particular interest in space, where astronauts frequently view one another in orientations other than the upright. Sixteen observers viewed individual facial images of six people on a computer screen; on a given trial, the image was either smiling or frowning. Each image was viewed when it was erect and when it was rotated (rolled) by 45 degrees, 90 degrees, 135 degrees, 180 degrees, 225 degrees and 270 degrees about the line of sight. The observers were required to respond as rapidly and accurately as possible to identify if the face presented was smiling or frowning. Measures of reaction time were obtained when the observers were both upright and supine. Analyses of variance revealed that mean reaction time, which increased with stimulus rotation (F=18.54, df 7/15, p (is less than) 0.001), was 22% longer when the faces were inverted than when they were erect, but that the orientation of the observer had no significant effect on reaction time (F=1.07, df 1/15, p (is greater than) .30). These data strongly suggest that the orientation of the image of a face on the observer's retina, but not its orientation with respect to gravity, is important in identifying the expression on the face.

Cohen, M. M.↗