Engineering PapersSearch

Engineering topics

Hardy, A. C.

Publications and source records attributed to Hardy, A. C..

Results of time-resolved radiation exposure measurements made during U.S. shuttle missions with a tissue equivalent proportional counter

Time resolved exposure measurements inside the crew compartment have been made during recent shuttle missions with the USAF Radiation Monitoring Equipment-III (RME-III), a portable four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. The missions had orbital inclinations ranging from 28 degrees to 57 degrees, and altitudes from 200-600km. Dose equivalent rates ranged from 40-5300 micro Sv/dy. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicle. Measurements indicate that medium- and high- Linear Energy Transfer (LET) particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Isa-dose rate contours have been developed from measurements made during the ST-28 mission. The drift rate of the South Atlantic Anomaly (SAA) is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and Galactic Cosmic Radiation (GCR) dose for the STS-28 mission were significantly lower than the measured values.

Golightly, M. J.

CAD-based stand-alone spacecraft radiation exposure analysis system: An application of the early man-tended Space Station

Major improvements have been completed in the approach to analyses and simulation of spacecraft radiation shielding and exposure. A computer-aided design (CAD)-based system has been developed for determining the amount of shielding provided by a spacecraft and simulating transmission of an incident radiation environment to any point within or external to the vehicle. Shielding analysis is performed using a customized ray-tracing subroutine contained within a standard engineering modeling software package. This improved shielding analysis technique has been used in several vehicle design programs such as a Mars transfer habitat, pressurized lunar rover, and the redesigned international Space Station. Results of analysis performed for the Space Station astronaut exposure assessment are provided to demonastrate the applicability and versatility of the system.

Appleby, M. H.

Description, analysis and impact of major solar activity during recent U.S. Shuttle missions

Since STS-26, three large solar events have occurred during Shuttle missions: a geomagnetic storm during STS-29 and solar particle events (SPEs) during STS-28 and -34. The maximum dose to a crew attributed to an SPE was estimated to be 30 micro-Gy. Time-resolved dosimetry measurements of the SPE dose during STS-28 were made using the USAF Radiation Monitoring Equipment. Comparison of calculated and measured dose demonstrated a discrepancy, possibly a result of deficiencies in the geomagnetic cutoff model used. This experience demonstrates that dose from an SPE is strongly dependent on numerous factors such as orbit inclination, SPE start time, spectral parameters and geomagnetic field conditions; the exact combination of these factors is fortuitous. New sources of data and procedures are being investigated, including real-time tracking of auroral oval positions or determination of particle cutoff latitudes, for incorporation into operational Shuttle radiation support practices.

Golightly, M. J.

Space Shuttle dosimetry measurements with RME-III

A description of the radiation monitoring equipment (RME-III) dosimetry instrument and the results obtained from six Space Shuttle flights are presented. The RME-III is a self-contained, active (real-time), portable dosimeter system developed for the USAF and adapted for utilization in measuring the ionizing radiation environment on the Space Shuttle. This instrument was developed to incorporate the capabilities of two earlier radiation instruments into a single unit and to minimize crew interaction times with longer battery life and expanded memory capacity. Flight data has demonstrated that the RME-III can be used to accurately assess dose from various sources of exposure, such as that encountered in the complex radiation environment of space.

Hardy, K. A.

A parametric study of space radiation exposures to critical body organs for low earth orbit missions

It is shown that it is possible to calculate the extent of the exposure to space radiation of a specific body organ. Using a computerized anatomical man model and models of radiation environments and spacecraft shielding, a parametric study was carried out for several Space-Shuttle scenarios. The dose equivalent data for several blood-forming organ locations are presented (for a solar-minimum epoch) as a function of altitude and the shielding material, and the results are compared with the NASA crew exposure limits for these body organs.

Atwell, W.

Space radiation shielding analysis and dosimetry for the Space Shuttle program

Active and passive radiation dosimeters have been flown on every Space Shuttle mission to measure the naturally-occurring, background Van Allen and galactic cosmic radiation doses that astronauts and radiation-sensitive experiments and payloads receive. A review of the various models utilized at the NASA/Johnson Space Center, Radiation Analysis and Dosimetry is presented. An analytical shielding model of the Shuttle was developed as an engineering tool to aid in making premission radiation dose calculations and is discussed in detail. The anatomical man models are also discussed. A comparison between the onboard dosimeter measurements for the 24 Shuttle missions to date and the dose calculations using the radiation environment and shielding models is presented.

Atwell, William

Measurement of differential proton spectra onboard the Space Shuttle using a thermoluminescent dosimetry system

An experimental technique that permits the extraction of orbit-averaged, differential energy spectra of trapped radiation belt protons using simple passive detectors is described. An inversion technique is used for the data analysis. The basic principle of the described system is measurement of the energy deposited in six thermoluminescent (TLD) detector assemblies behind various spherical absorbers. The technique has been applied to a detector assembly flown on four Shuttle flights. Although severe restraints were placed on the flight package, the differential energy spectra derived from these measurements are in good agreement with analytical results using a modified trapped proton environment model. The technique shows good promise for measuring the spectra in low inclination orbits where the flux of high energy galactic cosmic rays protons is small. Modifications to the detector assembly to improve the accuracy and to extend the range of the system to higher energies are suggested.

STS-51J Shuttle Project

Occulting-filter method for obtaining flashing-light visibility data

Occulting-filter technique allows several types of flashing-light visibility data necessary for rendezvous and docking maneuvers, to be obtained for studying the perception of flashes at the visual threshold. The indications are that the method can be used to compare sources of radically different spectral composition.

Hardy, A. C.