NUMERICAL NOISE STUDY IN EIC BEAM-BEAM SIMULATIONS

In the Electron-Ion Collider (EIC) design, a flat beam collision scheme is adopted to achieve 1034 cm -2 s -1 luminosity. We found that the vertical growth of the proton beam is much larger than of the round beam. In this article we present the numerical noise study about the number of macroparticles, the electron slice number, and the electron bunch length. Both weak-strong and strong-strong simulation methods are used. It turns out the proton emittance growth in the strong-strong simulation mainly comes from the numerical noise. This study helps us to perform beam-beam simulation correctly for the EIC.

43 PARTICLE ACCELERATORS↗

STUDY OF HARMONIC CRAB CAVITY IN EIC BEAM-BEAM SIMULATIONS

In the Electron-Ion Collider (EIC) design, crab cavities are adopted to compensate the geometric luminosity loss from the crossing angle. From previous studies, higher-order synchro-betatron resonances are excited since the hadron beam is long and the crossing angle is large. To reduce the luminosity degradation rate, different combinations of harmonic crab cavities are studied with both weak-strong and strong-strong simulation methods. The frequency map analysis (FMA) is also used for comparison. This study helps determine the crab cavity parameters for the future EIC.

43 PARTICLE ACCELERATORS↗

FULL RANGE TUNE SCAN STUDIES USING GRAPHICS PROCESSING UNITS WITH CUDA IN EIC BEAM-BEAM SIMULATIONS

The hadron beam in the Electron-Ion Collider (EIC) suffers high order betatron and synchro-betatron resonances. In this paper, we present a weak-strong full range (0.0 ~ 0.5) fractional tune scan with a step size as small as 0.001. Multiple Graphics Processing Units (GPUs) are used to speed up the simulation. A code parallelized with MPI and CUDA is implemented. The good tune region from weak-strong scan is further checked by the self-consistent strong-strong simulation. This study provides beam dynamics guidance in choosing proper working points for the future EIC.

43 PARTICLE ACCELERATORS↗

SU-F-T-59: The Effect of Radiotherapy Dose On Immunoadjuvants

Purpose: Combining radiotherapy with immunotherapy is a promising approach to enhance treatment outcomes for cancer patients. This in-vitro study investigated which radiotherapy doses could adversely affect the function of anti-CD40 mAb, which is one of the key immunoadjuvants under investigations for priming such combination therapy. Methods: Human monocyte derived THP-1 cells were treated with 100ng/mL of PMA in chamber slides to differentiate into macrophage. The THP-1 differentiated macrophages were treated with 2uL/ml of the anti-CD40 mAb and incubated at 37°C and 5% CO2 for 24 hours. Anti-CD40 mAb treated cells were then irradiated at different doses of x-rays: (0, 2, 4, 6, 8, and 12) Gy using the Small Animal Radiotherapy Research Platform (SARRP). After radiation, the cells were left at 4°C for 2 hours followed by immunofluorescence assay. A Nikon inverted live-cell imaging system with fluorescence microscope was used to image the cells mounted on a slide fixed with Dapi. For comparison, an ELISA assay was performed with the antibody added to 3mL of PBS in multiple 10mm dishes. The 10mm dishes were irradiated at different x-ray dose: (0, 2, 4, 6, 8. 10, 12, and 15) Gy using the SARRP. Results: The anti-CD40 mAb activating the macrophages starts to lose their viability due to radiation dose between 8Gy to 12Gy as indicated by the immunofluorescence assay. The ELISA assay, also indicated that such high doses could lead to loss of the mAb’s viability. Conclusion: This work suggests that high doses like those employed during Stereotactic Ablative Radiotherapy may affect the viability of immunoadjuvants such as anti-CD 40. This study avails in-vivo experiments combining radiotherapy with anti-cd40 to get synergistic outcomes, including in the treatment of metastatic disease.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP3-02: In-Situ Dose Painting Using Gold Nanoparticles Released From Cylindrically Shaped Fiducials During External Beam Radiation Therapy

Purpose: Recent studies have shown that the presence of Gold Nanoparticles (GNPs) in tumor tissue can lead to significant dose enhancement (DE) during External Beam Radiation Therapy (EBRT). In this in-silico study we investigate EBRT with in-situ dose painting using GNPs released from cylindrically shaped GNP-loaded fiducials. Methods: Reported Biologically Target/Tumor Volumes (BTVs) for 12 prostate carcinoma patients were employed in this study. Distribution of the GNPs after burst release from the fiducial (1.5mm diameter and 5mm length) located in the center of the spherically assumed BTV were modeled by isotropic and free diffusion without boundary condition and under the assumption of superposition. An experimentally determined diffusion coefficient for 10nm nanoparticles was adapted for investigating other GNP sizes (2, 5, 15, and 20nm) using the Stokes-Einstein equation. The maximum size of GNPs to achieve a minimal DE Factor (DEF) of 1.1 for 6MV EBRT using a fiducial-load of 30mg/g was calculated for typical periods of 14 and 21 days after implantation. Further, the minimal fiducial-load needed to achieve a clinically significant DEF of 1.2 was computed for 2nm GNPs. Results: Results showed that a minimal DEF of 1.1 could be reached for the smallest patient BTV using a maximal GNP size of 10nm and 20nm after 14 and 21 days, respectively. With increasing BTV smaller GNPs are required to ensure the same DEF. In particular, the largest BTV requires 2nm GNPs for periods of 14 and 21 days. Meanwhile, the required fiducial-load to reach a minimal DEF of 1.2 after 14 days was found in the range of 17mg/g and 59mg/g for all reported BTVs. Conclusion: This preliminary study indicates a strong dependence on GNP size and fiducial-load to realize a significant DE. The findings avail further research towards development of GNP-loaded fiducials for significantly enhancing radiotherapy for cancer patients.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRA-09: Using Graphene Oxide Nano Flakes During Image Guided Radiotherapy to Minimize the Potential of Cancer Recurrence Or Metastasis

Purpose: An increasing number of studies show that cancer stem cells (CSCs) become more invasive (metastatic) and may escape into the blood stream and lymph nodes during radiotherapy (RT), before they have received a lethal dose during RT. Other Studies have shown that Graphene oxide (GO) can selectively inhibit the proliferative expansion of CSCs across multiplicative tumor types. In this study we investigate the feasibility of using GO during radiotherapy (RT) to minimize the escape of CSCs towards preventing cancer metastasis or recurrence. Methods: We hypothesize that sufficient amount of GO nano-flakes (GONFs) released from new design radiotherapy biomaterials (fiducials or spacers) loaded with the GONFs can reach all tumor cells within typical times of 14 or 21days before the beginning of image-guided radiotherapy (IGRT) following implantation. To test this hypothesis, the space-time diffusion of the GONFs was investigated. Knudsen’s and Cunningham’s numbers were calculated to get the Stokes’ velocities and mobility values, according to these values, diffusion coefficients were calculated. In a previous study it was shown that GONFs concentration of 50 µg/ml were effective. In the diffusion study, 100 µg/ml was chosen as an initial concentration because it has been shown to be relatively non-toxic. Results: The 50 µg/ml concentration in a 2 cm diameter volume of lung tumor could be only achieved using 2 nm and 6 nm GONFs with respective diffusion times of 14 and 21 days. As expected, increased nanoflake size requires longer times to achieve the target 50 µg/ml concentration. Conclusion: The preliminary results indicate the potential of using GONFs delivered via new design radiotherapy biomaterials (e.g. fiducials) to inhibit the proliferative expansion of CSCs. The study avails ongoing in-vivo studies on using GONFs to enhance treatment outcomes for cancer patients.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-04: Leveraging the Abscopal Effect Via New Design Radiotherapy Biomaterials Loaded with Immune Checkpoint Inhibitors

Purpose: Studies show that stereotactic body radiation therapy (SBRT) of a primary tumor in combination with immune checkpoint inhibitors (ICI) could Result in an immune-mediated regression of metastasis outside the radiation field, a phenomenon known as abscopal effect. However toxicities due to repeated systematic administration of ICI have been shown to be a major obstacle in clinical trials. Towards overcoming these toxicity limitations, we investigate a potential new approach whereby the ICI are administered via sustained in-situ release from radiotherapy (RT) biomaterials (e.g. fiducials) coated with a polymer containing the ICI. Methods: New design RT biomaterials were prepared by coating commercially available spacers/fiducials with a biocompatible polymer (PLGA) film containing fluorescent nanoparticles of size needed to load the ICI. The release of the nanoparticles was investigated in-vitro. Meanwhile, an experimentally determined in- vivo nanoparticle diffusion coefficient was employed in analytic calculations based on Fick’s second law to estimate the time for achieving the concentrations of ICI in the tumor draining lymph node (TDLN) that are needed to engender the abscopal effect during SBRT. The ICI investigated here was anti-CTLA-4 antibody (ipilimumab) at approved FDA concentrations. Results: Our in -vitro study results showed that RT biomaterials could be designed to achieve burst release of nanoparticles within one day. Meanwhile, our calculations indicate that for a 2 to 4 cm tumor it would take 4–22 days, respectively, following burst release, for the required concentration of ICI nanoparticles to accumulate in the TDLN during SBRT. Conclusion: Current investigations combining RT and immunotherapy involve repeated intravenous administration of ICI leading to significant systemic toxicities. Our preliminary results highlight a potential new approach for sustained in-situ release of the ICI from new design RT biomaterials. These results provide impetus for more studies to leverage the powerful abscopal effect, while minimizing systemic toxicities through the new approach.

60 APPLIED LIFE SCIENCES↗

Experiments and modeling of variably permeable carbonate reservoir samples in contact with CO₂-acidified brines

Reactive experiments were performed to expose sample cores from the Arbuckle carbonate reservoir to CO₂-acidified brine under reservoir temperature and pressure conditions. The samples consisted of dolomite with varying quantities of calcite and silica/chert. The timescales of monitored pressure decline across each sample in response to CO₂ exposure, as well as the amount of and nature of dissolution features, varied widely among these three experiments. For all samples cores, the experimentally measured initial permeability was at least one order of magnitude or more lower than the values estimated from downhole methods. Nondestructive X-ray computed tomography (XRCT) imaging revealed dissolution features including “wormholes,” removal of fracture-filling crystals, and widening of pre-existing pore spaces. In the injection zone sample, multiple fractures may have contributed to the high initial permeability of this core and restricted the distribution of CO₂-induced mineral dissolution. In contrast, the pre-existing porosity of the baffle zone sample was much lower and less connected, leading to a lower initial permeability and contributing to the development of a single dissolution channel. While calcite may make up only a small percentage of the overall sample composition, its location and the effects of its dissolution have an outsized effect on permeability responses to CO₂ exposure. The XRCT data presented here are informative for building the model domain for numerical simulations of these experiments but require calibration by higher resolution means to confidently evaluate different porosity-permeability relationships.

58 GEOSCIENCES↗