Engineering Papers⌕ Search

Engineering topics

Hanson, David

Publications and source records attributed to Hanson, David.

21 records · Page 2

Laboratory studies of the nitric acid trihydrate - Implications for the south polar stratosphere

Vapor pressures of HNO3 and H2O have been measured over the trihydrate crystal, formed by vapor deposit on a glass surface. In the temperature range 190 to 205 K the two phase-equilibrium trihydrate/vapor was studied by adding and removing H2O. Coexistence equilibria vapor pressures of trihydrate/solid solutions of HNO3 in ice and of mono-/trihydrate were also measured. Results show that for typical mixing ratios of H2O and HNO3 found in the lower stratosphere (3 ppm H2O, 5 ppb HNO3) the trihydrate would start to form at temperatures about 7 K higher than the ice point. The pressure of atmospheric HNO3 would rapidly decrease as the atmosphere cools without large changes in partial pressures of H2O. These laboratory results provide information on the formation of polar stratospheric clouds containing H2O and HNO3.

Hanson, David↗

Laboratory studies of HNO3/H2O mixtures at low temperatures

The possibility of stratospheric HN3 condensing out of the gas-phase at low temperatures has become important in the chemical explanations of the rapid loss of Antarctic ozone in spring. Consequently, knowledge about the behavior of the vapor pressures of water and HNO3 over HNO3/water mixtures at stratospheric temperatures is needed to determine if HNO3 could condense, and by how much the HNO3 vapor pressure could be depressed. Laboratory investigations of vapor pressures above HNO3/water mixtures are described. Vapor pressures were initially measured over liquid and frozen bulk mixtures contained in a glass still which was attached to a stainless steel vacuum chamber. The total pressure in the chamber was monitored with a precision pressure sensor, and the vapor pressures of HNO3, water and impurities were analyzed with a mass spectrometer beam system. In a second set of experiments, vapor deposits were made to produce ice and the mono- and trihydrate of HNO3. Further data and conclusions are presented.

Hanson, David↗

The vapor pressures of solid and liquid ozone

Vapor pressures of solid and liquid ozone have been measured over a temperature range 87 to below 66 K. The experiment was performed under flow conditions, and the gas was analyzed by a precision mass spectrometer system. In the range of solid ozone two forms, supercooled and crystalline ozone, were found. A least-square fit of the data for crystalline ozone resulted in the equation log P(torr) = A + B/T, where A = 10.460 and B = -1021.6. The estimated uncertainty of the data is + or - 1.0 percent. A triple-point temperature of 79.6 + or - 0.3 K was found where supercooled and crystalline ozone data intersect.

Hanson, David↗