Engineering PapersSearch

Engineering topics

Hansen, L. K.

Publications and source records attributed to Hansen, L. K..

Extracellular matrix controls tubulin monomer levels in hepatocytes by regulating protein turnover

Cells have evolved an autoregulatory mechanism to dampen variations in the concentration of tubulin monomer that is available to polymerize into microtubules (MTs), a process that is known as tubulin autoregulation. However, thermodynamic analysis of MT polymerization predicts that the concentration of free tubulin monomer must vary if MTs are to remain stable under different mechanical loads that result from changes in cell adhesion to the extracellular matrix (ECM). To determine how these seemingly contradictory regulatory mechanisms coexist in cells, we measured changes in the masses of tubulin monomer and polymer that resulted from altering cell-ECM contacts. Primary rat hepatocytes were cultured in chemically defined medium on bacteriological petri dishes that were precoated with different densities of laminin (LM). Increasing the LM density from low to high (1-1000 ng/cm2), promoted cell spreading (average projected cell area increased from 1200 to 6000 microns2) and resulted in formation of a greatly extended MT network. Nevertheless, the steady-state mass of tubulin polymer was similar at 48 h, regardless of cell shape or ECM density. In contrast, round hepatocytes on low LM contained a threefold higher mass of tubulin monomer when compared with spread cells on high LM. Furthermore, similar results were obtained whether LM, fibronectin, or type I collagen were used for cell attachment. Tubulin autoregulation appeared to function normally in these cells because tubulin mRNA levels and protein synthetic rates were greatly depressed in round cells that contained the highest level of free tubulin monomer. However, the rate of tubulin protein degradation slowed, causing the tubulin half-life to increase from approximately 24 to 55 h as the LM density was lowered from high to low and cell rounding was promoted. These results indicate that the set-point for the tubulin monomer mass in hepatocytes can be regulated by altering the density of ECM contacts and changing cell shape. This finding is consistent with a mechanism of MT regulation in which the ECM stabilizes MTs by both accepting transfer of mechanical loads and altering tubulin degradation in cells that continue to autoregulate tubulin synthesis.

Non-NASA Center

Status of research on advanced thermionic converters

It is shown that it is possible to controllably and continuously elevate the electron temperature in the plasmatron thermionic energy converter from the emitter temperature to the maintenance electron temperature for the diode arc mode. This ability and the apparent validity of an elementary analytical model of the plasma should make possible the optimization and evaluation of operation under strong ionization conditions for which the plasma resistance should be acceptably low. Measurement of the vacuum space charge arising from the emission from a surface in cesium vapor indicates the presence of a substantial negative ion emission current. Apparatus has been constructed for identifying and directly measuring the flux of positive, negative and neutral species emitted from an electrode surface in a cesium vapor diode. The primary purpose of the investigation is to determine the influence of negative ion emission on the effective work function of thermionic converter electrodes. Initial data indicate the presence of H(-), Cs(-) and possibly C(-) and CH(-).

Hatch, G. L.

The plasmatron: Advanced mode thermionic energy conversion

A theory of the plasmatron was developed. Also, a wide range of measurements were obtained with two versatile, research devices. To gain insight into plasmatron performance, the experimental results are compared with calculations based on the theoretical model of plasmatron operation. Results are presented which show that the plasma arc drop of the conventional arc (ignited) mode converter can be suppressed by use of an auxiliary ion source. The improved performance, however, is presently limited to low current densities because of voltage losses due to plasma resistance. This resistance loss could be suppressed by an increase in the plasma electron temperature or a decrease in spacing. Plasmatron performance characteristics for both argon and cesium are reported. The argon plasmatron has superior performance. Results are also presented for magnetic cutoff effects and for current distributing effects. These are shown to be important factors for the design of practical devices.

Hansen, L. K.

Thermo electronic laser energy conversion

The thermo electronic laser energy converter (TELEC) is described and compared to the Waymouth converter and the conventional thermionic converter. The electrical output characteristics and efficiency of TELEC operation are calculated for a variety of design variables. Calculations and results are briefly outlined. It is shown that the TELEC concept can potentially convert 25 to 50 percent of incident laser radiation into electric power at high power densities and high waste heat rejection temperatures.

Hansen, L. K.

The plasmatron as an advanced performance thermionic converter

A study concerned with the improvement of thermionic converter performance has shown that the plasma arc drop of the conventional arc (ignited) mode converter can be suppressed by use of an auxiliary ion source as in a plasmatron converter. However, this improved performance is now limited to low current densities and narrow interelectrode spacings because of voltage losses due to plasma resistance. An examination of plasmatron performance characteristics for both argon and cesium plasma has shown that the argon plasmatron is superior.

Hansen, L. K.

Practical aspects of plasma processes in thermionic energy converters

Over a decade of cesium vapor thermionic converter research has yielded sufficient understanding of the basic plasma processes to permit application of this understanding to improvement of converter performance. A performance index is defined which relates such converter improvements directly to increases in system performance. A prime practical objective of current research is to reduce or eliminate the arc potential drop presently required to sustain the plasma in the ignited cesium diode. This will substantially increase the energy conversion efficiency, and will permit operation at substantially lower emitter temperatures without requiring lower collector (heat rejection) temperature. Present work is concentrating on evaluating and reducing to practice the several methods employing auxiliary ion sources to eliminate the arc drop which were demonstrated over a decade ago: i.e., various ignited and unignited triode concepts, and the pulse-enhanced diode and triode. These methods are reviewed in light of present understanding and recent experimental data.

Rasor, N. S.

Advanced thermionic energy conversion

Basic analytical and experimental exploration was conducted on several types of advanced thermionic energy converters, and preliminary analysis was performed on systems utilizing advanced converter performance. The Pt--Nb cylindrical diode which exhibited a suppressed arc drop, as described in the preceding report, was reassembled and the existence of the postulated hydrid mode of operation was tentatively confirmed. Initial data obtained on ignited and unignited triode operation in the demountable cesium vapor system essentially confirmed the design principles developed in earlier work, with a few exceptions. Three specific advanced converter concepts were selected as candidates for concentrated basic study and for practical evaluation in fixed-configuration converters. Test vehicles and test stands for these converters and a unique controlled-atmosphere station for converter assembly and processing were designed, and procurement was initiated.

Britt, E. J.