Engineering Papers⌕ Search

Engineering topics

Han, Baoxi

Publications and source records attributed to Han, Baoxi.

Low-energy H- beam injectors for particle accelerators: upgrade requirements, challenges and future plans [Slides]

High brightness, negative hydrogen ion sources are used extensively in large, accelerator-based, user facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Much larger beams of H- ions are also utilized for neutral beams injection into fusion machines and will be discussed in a separate companion presentation. Some of the accelerator facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), the CERN LHC injector, the Chinese Spallation Neutron Source (CSNS) as well as numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly with cyclotrons. Many facilities are currently working on various improvement / upgrade projects, both in the near and long term, which are driving further development of their ion source and LEBT (Low Energy Beam Transport) and, in some cases, their overall front end injector system. This report will first provide a simple description of each facilities existing ion source and LEBT and summarize the operational parameters which are currently being routinely injected into their accelerators. Next, the parametric goals of each of the facilities upgrade projects are specified as well as development efforts currently underway to meet these requirement and improvement goals. It is hoped that that this work will not only capture the current state-of-the-art of worldwide H- beam injectors and clarify the research goals and efforts of the community in general but will also encourage further inter laboratory collaborations.

43 PARTICLE ACCELERATORS↗

Design improvements to the SNS ion source and diagnostics

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.

47 OTHER INSTRUMENTATION↗

Status of the Spallation Neutron Source beam test facility and progress of beam dynamics studies

The Spallation Neutron Source (SNS) Beam Test Facility (BTF) supports the study of beam dynamics in the front end of a high power LINAC. The BTF combines a replica of the SNS front end, including nearly-identical ion source, RFQ and MEBT, with extensive phase space diagnostics and a FODO transport line. Diagnostic capabilities include direct measurement of 6D phase space distribution and detection of halo distributions to a sensitivity of greater than one part-per-million. The goal of on-going BTF studies is to demonstrate accurate particle-in-cell modeling of halo growth and evolution by leveraging unprecedented accuracy in the description of the initial beam distribution. This work is motivated by operational experience at the SNS, which currently operates with beam loss that cannot be described by any model. This paper summarizes progress in the BTF beam study program as well as diagnostics development and recent upgrades to the beamline configuration.

Ruisard, Kiersten↗

Overview of H- radio frequency ion sources for particle accelerators

Particle accelerators are among the most important scientific tools of the modern era. Large accelerator complexes have supported scientific user facilities which have had an enormous societal impact spanning many decades and enabling the work of thousands of scientific users worldwide contributing to many Nobel prizes in physics, biology and chemistry [1]. Many of the large hadron facilities employ accelerator complexes which include cyclotrons, synchrotrons, storage rings, linear or tandem accelerators and deliver ion beams of very high-intensity and/or very high-energy to their user facilities. These accelerator complexes require the injection of high-intensity beams of ions which are produced within an ion source and formed within a plasma or by bombardment of a surface [2]. Increasingly, RF systems are being utilized, to generate these ion-rich plasmas due to their high reliability and minimal use of consumable components. This report will first discuss the basic mechanisms of ion formation and plasma generation as well as some specifics of RF/microwave generators, matching circuits and plasma coupling structures typically employed. A detailed discussion will then be given of the RF-driven negative ion source systems employed by US Spallation Neutron Source as well as those used in similar facilities located around the globe. REFERENCES [1]Vladimir Shiltsev, “Particle beams behind physics discoveries”, Physics Today 73, Issue 4, 32 (2020) [2]Robert Welton et al, “Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations”, Journal of Physics Conf Series, 2244 012045

Welton, Robert F.↗

Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations

High brightness, negative hydrogen ion sources are used extensively in scientific facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Several well-known facilities now have considerable experience with operating a variety of sources such as RF-, filament-, magnetron- and Penning-type H- ion sources. These facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly on cyclotrons and, most recently, the CERN-LINAC-1 injector. This report first summarizes the current performance of these ion sources in routine, daily operations with attention toward source service-periods and availability metrics. Sustainability issues encountered at each facility are also reported and categorized to identify areas of common concern and key issues. Recent ion source improvements to address these issues are also discussed as well as plans for meeting future facility upgrade requirements.

Welton, Robert F.↗

Recent performance of the SNS H - ion source with a record long run

The Spallation Neutron Source (SNS) accelerator system includes a 65 keV H - injector, a 2.5 MeV radio frequency quadrupole (RFQ), a 1 GeV linac chain (DTL-CCL-SCL) and an accumulator ring. The H - injector consists of an RF-driven, Cs-enhanced, multi-cusp H - ion source and a compact, two-lens electrostatic low energy beam transport (LEBT). In 2018, a new RFQ was installed in place of the original RFQ along with upgraded ion source support infrastructure. This paper presents the operational performance and some highlights of beam studies with the SNS ion source since the new RFQ was put into operation. SNS routinely operates at 1.4 MW average beam power for three run cycles per year. During the most recently finished run, FY20B, we operated a single source for the entire run spanning ~4 months with a >99.5% availability. A single dose of cesiation was conducted during the ion source startup which yielded ≥54 mA current for the entire run with just few minor adjustments of parameters.

Han, Baoxi↗

H- ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced by spallation of liquid Hg due to bombardment of short (~1µs), intense (~35 A) pulses of protons delivered at 60 Hz from a storage ring which is fed by a high-intensity, 1 GeV H- LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50-60 mA of H- ions with a duty-factor of 6% for maintenance-free runs of ~120 days with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting these achievements: this report provides some historical highlights of this effort, describes our current ion source testing facilities, discusses the goals of the program and finally provides a snapshot of some of our ongoing R&D activities. In particular, we have recently simplified and improved the reliability of the plasma ignition gun for the external antenna ion source which is discussed in detail.

Welton, Robert F.↗

Tests of Cs-Free Operation of the SNS RF H⁻ Ion Sources

Tests were performed at SNS in collaboration with visiting colleagues from ISIS, UK to evaluate the uncesiated beam performance of the SNS RF H⁻ ion sources. Two spare experimental sources, one with internal antenna and one with external antenna were used for the tests. The beam currents achieved with Cs-free operations accounted for about 1/3 to 1/2 of the beam currents produced with cesiated operations. ~17 mA uncesiated H⁻ current was demonstrated within the tested RF power range up to 65 kW with the internal antenna source and ~15 mA with up to 40 kW RF with the external antenna source. In Cs-free operations, the power supply for the electron dumping electrode was loaded down below its set voltage but was not too drastic to tamper the operation.

Han, Baoxi↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗