Engineering Papers⌕ Search

Engineering topics

Hamstad, M. A.

Publications and source records attributed to Hamstad, M. A..

Reflections of AE Waves in Finite Plates: Finite Element Modeling and Experimental Measurements

The capability of a three-dimensional dynamic finite element method for predicting far-field acoustic emission signals in thin plates of finite lateral extent, including their reflections from the plate edges, was investigated. A lead break (Hsu-Neilsen) source to simulate AE was modeled and used in the experimental measurements. For the thin plate studied, the signals were primarily composed of the lowest order symmetric (S0) and antisymmetric (A0) Lamb modes. Experimental waveforms were detected with an absolutely calibrated, wideband, conical element transducer. The conditions of lead fractures both on the surface of the plate as well as on the edge of the plate were investigated. Surface lead breaks preferentially generate the A0 mode while edge lead breaks generate the S0 mode. Reflections of developed plate waves from both normal and oblique incidence angles were evaluated. Particularly interesting for the case of the lead break on the plate edge were S0 waves produced by the interaction of a Rayleigh wave with the plate corner and by a bulk shear wave mode converting at the side edge. The Rayleigh wave, in this case, propagated along the specimen edge. For all cases considered, the experimental measurements were in good agreement with the predictions of the finite element model.

Prosser, W. H.↗

Finite Element and Plate Theory Modeling of Acoustic Emission Waveforms

A comparison was made between two approaches to predict acoustic emission waveforms in thin plates. A normal mode solution method for Mindlin plate theory was used to predict the response of the flexural plate mode to a point source, step-function load, applied on the plate surface. The second approach used a dynamic finite element method to model the problem using equations of motion based on exact linear elasticity. Calculations were made using properties for both isotropic (aluminum) and anisotropic (unidirectional graphite/epoxy composite) materials. For simulations of anisotropic plates, propagation along multiple directions was evaluated. In general, agreement between the two theoretical approaches was good. Discrepancies in the waveforms at longer times were caused by differences in reflections from the lateral plate boundaries. These differences resulted from the fact that the two methods used different boundary conditions. At shorter times in the signals, before reflections, the slight discrepancies in the waveforms were attributed to limitations of Mindlin plate theory, which is an approximate plate theory. The advantages of the finite element method are that it used the exact linear elasticity solutions, and that it can be used to model real source conditions and complicated, finite specimen geometries as well as thick plates. These advantages come at a cost of increased computational difficulty, requiring lengthy calculations on workstations or supercomputers. The Mindlin plate theory solutions, meanwhile, can be quickly generated on personal computers. Specimens with finite geometry can also be modeled. However, only limited simple geometries such as circular or rectangular plates can easily be accommodated with the normal mode solution technique. Likewise, very limited source configurations can be modeled and plate theory is applicable only to thin plates.

Prosser, W. H.↗

Aging results for PRD 49 III/epoxy and Kevlar 49/epoxy composite pressure vessels

Kevlar 49/epoxy composite is growing in use as a structural material because of its high strength-to-weight ratio. Currently, it is used for the Trident rocket motor case and for various pressure vessels on the Space Shuttle. In 1979, the initial results for aging of filament-wound cylindrical pressure vessels which were manufactured with preproduction Kevlar 49 (Hamstad, 1979) were published. This preproduction fiber was called PRD 49 III. This report updates the continuing study to 10-year data and also presents 7.5-year data for spherical pressure vessels wound with production Kevlar 49. For completeness, this report will again describe the specimens of the original study with PRD 49 as well as specimens for the new study with Kevlar 49.

Hamstad, M. A.↗

High-performance fiber/epoxy composite pressure vessels

Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

Chiao, T. T.↗

Deformation and failure information from composite materials via acoustic emission

The paper reviews some principles of applying acoustic emission (AE) to the study of fiber-composite materials and structures. This review covers the basics of using AE to monitor the deformation and fracture processes that occur when fiber-composite materials are stressed. Also, new results in some areas of current research interest are presented. The following areas are emphasized: study of couplants for AE testing of composites, evaluation of a special immersion-type AE transducer, and wave propagation complications and the development of techniques for locating AE sources in Kevlar 49/epoxy composite pre

Hamstad, M. A.↗

Variabilities detected by acoustic emission from filament-wound Aramid fiber/epoxy composite pressure vessels

Two hundred and fifty Aramid fiber/epoxy pressure vessels were filament-wound over spherical aluminum mandrels under controlled conditions typical for advanced filament-winding. A random set of 30 vessels was proof-tested to 74% of the expected burst pressure; acoustic emission data were obtained during the proof test. A specially designed fixture was used to permit in situ calibration of the acoustic emission system for each vessel by the fracture of a 4-mm length of pencil lead (0.3 mm in diameter) which was in contact with the vessel. Acoustic emission signatures obtained during testing showed larger than expected variabilities in the mechanical damage done during the proof tests. To date, identification of the cause of these variabilities has not been determined.

Hamstad, M. A.↗

Advanced technology for minimum weight pressure vessel system

Bosses were made of fiber/resin composite materials to evaluate their potential in lightweight pressure vessels. An approximate 25% weight savings over the standard aluminum boss was achieved without boss failures during burst tests. Polymer liners and metal liners are used in fiber composite pressure vessels for containment of gases. The internal support of these liners required during the filament winding process has previously been provided by dissolvable salt mandrels. An internal pressurization technique has been developed which allows overwinding the liner without other means of support and without collapse. Study was made of several additional concepts including styrene/Saran, styrene/flexible epoxy.

Hamstad, M. A.↗

Graphite/epoxy pressure vessels lined with ultra-thin titanium

Filament-wound, titanium-lined, fiber/epoxy pressure vessels were made using a very high-strength graphite fiber (3570-MPa typical fiber strength). The 0.254-mm-thick titanium liner was used to improve burst performance. The pressure vessels achieved an average burst performance of 241 kPa.cu m/kg, and the fatigue life of titanium liners with good welds (cycled to 50% of the average expected burst pressure) was in excess of 2000 cycles.

Hamstad, M. A.↗

Considerations for acoustic emission monitoring of spherical Kevlar/epoxy composite pressure vessels

We are continuing to research the applications of acoustic emission testing for predicting burst pressure of filament-wound Kevlar 49/epoxy pressure vessels. This study has focused on three specific areas. The first area involves development of an experimental technique and the proper instrumentation to measure the energy given off by the acoustic emission transducer per acoustic emission burst. The second area concerns the design of a test fixture in which to mount the composite vessel so that the acoustic emission transducers are held against the outer surface of the composite. Included in this study area is the calibration of the entire test setup including couplant, transducer, electronics, and the instrument measuring the energy per burst. In the third and final area of this study, we consider the number, location, and sensitivity of the acoustic emission transducers used for proof testing composite pressure vessels.

Hamstad, M. A.↗

Fatigue performance of metal-lined graphite/epoxy pressure vessels

Using an ultrahigh-strength graphite fiber, a program was started to develop a thin metal-lined fiber/epoxy pressure vessel that would have a fatigue life of over 1000 cycles. First, the performance factor of the fiber/epoxy composite was found to be 351 kN m/kg from the average of 18 rubber-lined pressure vessels. Then, both aluminum- and titanium-lined vessels were filament wound with the graphite fiber in an epoxy matrix. Several of these metal-lined vessels were subjected to hydraulic fatigue testing to about 50% of their expected burst pressures. The average fatigue life of the aluminum-lined vessels was 462 cycles; the average for the titanium-lined vessels was 2190 cycles.

Hamstad, M. A.↗

High-performance vessels from an aromatic polyamide fiber/epoxy composite

The investigation reported is concerned with the development of a filament-wound, ultralightweight composite vessel for the containment of cryogenic propellants and pressurant gases. The vessels are to be used within an operational temperature range from -253 C to ambient temperature. The fiber used for the process is Kevlar 49. The design and the fabrication of specimens and vessels are discussed along with the results obtained in a testing program.

Chiao, T. T.↗

Performance of filament-wound vessels from an organic fiber in several epoxy matrices

A study was carried out to select a state-of-the-art epoxy for wet filament winding. Ten epoxy systems were used to filament wind pressure vessels with a high-modulus, high-strength organic fiber. Data are reported on vessel performance, fiber strand strengths, and shear strengths for the different systems. Using our criteria (processibility, neat resin properties, and vessel performance), we find that an epoxy system based on the rubber-modified bis-phenol-F resin, diluted with vinyl cyclohexane dioxide and cured with mixed aromatic amines, can easily replace bis-phenol-A epoxies diluted with bis-(2, 3-epoxycyclopentyl) ether (such as ERL 2256 epoxy of Union Carbide) with comparable overall performance.

Chiao, T. T.↗

Fatigue life of organic fiber/epoxy pressure vessels

The cyclic fatigue life of 10.2-cm-diam cylindrical pressure vessels has been studied. The vessels were made of an organic fiber/epoxy composite. To determine the typical strength distribution of the vessels, 25 of them were internally pressurized until they burst. Twenty-five vessels were then tested under sinusoidal cycling at 1 Hz between 4% and 91% of the mean burst strength. An additional twenty-five vessels were tested between 4% and 91% with a rectangular pressure pulse at 1/3 Hz. A limited number of vessels were tested for stress rupture at the 91% level. Cyclic life was found to depend on time at peak load as well as the number of stress cycles.

Hamstad, M. A.↗

Polymer-lined filament-wound pressure vessels for nitrogen containment

A program has been started to develop fatigue-resistant polymeric liners for a filament-wound pressure vessel to contain nitrogen gas at room temperature. First, nitrogen permeation of butyl rubber sheet coated with Saran and Parylene C was studied in flat specimens. Then four 10-cm-diam cylindrical pressure vessels were prepared with chlorobutyl rubber liners coated with the same materials. These vessels were valved off after nitrogen gas pressurization to approximately 65% (approximately 11.7 MPa or 1700 psig) of their expected failure pressure. One vessel leaked. The other three vessels showed an average pressure loss of less than 1% per month. These pressure vessels have an average performance factor of approximately 370 kPa-cu m/kg (1,500,000 in.) based on composite mass.

Hamstad, M. A.↗

Organic fiber/epoxy pressure vessels

We evaluated the performance of an organic fiber in an epoxy matrix by winding 20-cm diam spherical and cylindrical pressure vessels of various designs. For the spherical vessels, we used soft aluminum liners 0.76 mm thick for a double boss design and 2 mm thick for a single boss design. For the cylindrical vessels, we used both 0.5-mm rubber liners and 0.76-mm soft aluminum liners. Vessels of both types were tested for burst pressure and cyclic fatigue at room temperature and liquid hydrogen temperature. The effects of temperature and vessel shape on the vessel performance factor were negligible. Our vessel fatigue data were marred by premature failure of the liners.

Chiao, T. T.↗

Tensile properties of an ultrahigh-strength graphite fiber in an epoxy matrix

The fiber performance and reinforcement potential for fiber composites of a special PAN-based graphite fiber were evaluated by testing the fiber's tensile properties in an epoxy matrix. Representative strand samples were taken from 30 spools of single-end, 1500-filament fiber to make over 5000 fiber/epoxy strand specimens using the filament-winding process. Characteristics studied were fiber uniformity, strength and modulus distributions at room and liquid-nitrogen temperatures, stress-strain behavior, the effect of strain rate on fiber strength, and acoustic emission during tensile loading to failure. The fiber was found to have a 3570-MPa failure stress, a 1.7% failure strain, a 206-GPa modulus, and a density of 1.77 Mg/cu m at 23 C. Liquid-nitrogen temperature and various strain rates had no significant effect on fiber tensile properties.

Chiao, T. T.↗

Polymer-lined filament-wound pressure vessels for nitrogen containment

A program has been started to develop fatigue-resistant polymeric liners for a filament-wound pressure vessel to contain nitrogen gas at room temperature. First, nitrogen permeation of butyl rubber sheet coated with Saran and Parylene C was studied in flat specimens. Then four 10-cm-diam cylindrical pressure vessels were prepared with chlorobutyl rubber liners coated with the same materials. These vessels were valved off after nitrogen gas pressurization to approximately 65% of their expected failure pressure. One vessel leaked. The other three vessels showed an average pressure loss of less than 1% per month. These pressure vessels have an average performance factor of about 370 kPa x cu m/kg based on composite mass.

Hamstad, M. A.↗

Acoustic emission produced during burst tests of filament-wound bottles.

Acoustic emission was recorded during burst tests of filament-wound, composite pressure vessels. Organic and graphite fibers were tested, and two different epoxy resin systems were used: one with a low and another with a relatively high cure temperature. Acoustic emission was studied for the effects of different winding patterns, artificial flaws, winding-induced fiber fraying, different resins, and different fibers. Small effects produced in the vessels by changes in these variables were greatly magnified when they appeared as changes in acoustic emission. They would, in fact, be difficult or impossible to detect by other test means.

Hamstad, M. A.↗