Engineering Papers⌕ Search

Engineering topics

Hamilton, Julie

Publications and source records attributed to Hamilton, Julie.

Electrolyte-Guided Design of Electroreductive CO Coupling on Copper Surfaces

Engineering the interfacial distribution of electrolytic ions can aid in modulating the electrocatalyst performance and efficiency. Using a hybrid quantum-classical modeling approach, we describe how predictive tuning of the solution microenvironment on copper can enhance the efficiency of CO 2 reduction (CO 2 R) to C 2 products. We elucidate how competing electrolyte constituents in mixed electrolyte solutions stimulate restructuring of the electrochemical double layer (EDL) and stabilize the OCCO* dimer (* denotes surface adsorbed), with predictions validated in flow reactors using copper gas diffusion electrodes (Cu-GDEs). Furthermore, our findings highlight how molecular-scale electrolyte engineering with informed models of the EDL can be leveraged to tailor CO 2 R activity and selectivity toward C 2 products.

36 MATERIALS SCIENCE↗

Advanced manufacturing for electrosynthesis of fuels and chemicals from CO 2

Advanced manufacturing (AM) represents an appealing approach for creating novel electrochemical systems for chemicals synthesis. In this work, we demonstrate AM for rapid development and testing for improved performance for the carbon dioxide reduction reaction across an evolution of vapor-fed reactor designs. In our final design, we observe activation- and mixed-control regimes for a variety of operating conditions via inlet CO 2 flow rate and electrochemical potential. Furthermore, we define a dimensionless number (Da) to identify mass transport regimes by exploring the impact of hypothesized underlying mass transport mechanisms, including consumption of CO 2 via OH - , increased local temperatures, and partial penetration of electrolyte into gas diffusion layer. The accelerated pace of reactor design and development led to high geometric current densities (500 mA cm -2 ), heightened selectivity (85.5% FE C 2+ products), and increased carbon dioxide conversion (16.6%) and cathodic energy efficiency (49.6% CO 2 R). Using AM vapor-fed reactors, we attain high ethylene (3.67%) and record ethanol (3.66%) yields compared to the literature. Finally, this work underscores the promise of AM for accelerating reactor design, understanding of governing phenomena, and improving the performance of catalytic systems.

36 MATERIALS SCIENCE↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Flow boiling of R134a in a large surface area microchannel array for high-flux laser diode cooling

Packaging high average power laser diode arrays that generate heat at an area average flux in excess of 1 kW·cm -2 is a significant engineering challenge. While liquid microchannel coolers have demonstrated up to 11.9 kW·cm -2 , two-phase microchannel array coolers have not achieved 1 kW cm -2 due to critical heat flux and flow instabilities. In the current study, flow boiling heat transfer was characterized by a 1 &times; 10 mm heated zone centered over a 5 &times; 10 mm array of 125 very small channels (45 &times; 200 &mu;m) with R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio. A test facility was used to characterize the heat transfer performance of boiling R134a over a range of saturation temperatures (15&deg;C to 25&deg;C), mass fluxes (735-2230 kg·m -2 ·s -1 ), and heat duties (< 110.3 W). During the tests, the calculated outlet vapor quality exceeded 61%, and the base heat flux at the heater reached a maximum of 1.1 kW·cm -2 . The resulting average experimental flow boiling heat transfer coefficients are found to be as large a 13.4 kW·m -2 ·K -1 over the approximately 3 mm two-phase region, with an average uncertainty of ± 2.72%. A substantial amount of heat was spread downstream via the low thermal resistance silicon floor. Specifically, between 29.5% and 55.1% of the heat dissipated in the two-phase region was dissipated over the heater. Finally, the remaining heat dissipated in the two-phase region was dissipated in the 2 mm of channel downstream of the heater. This suggests that heat spreading from the hotspot played a vital role in dissipating the heat load.

42 ENGINEERING↗

Ultrafast shock compression of PDMS-based polymers

The shock response of polymers is important for a number of commercial and defense–related applications, but it is difficult to obtain empirical shock response data over the wide range of preparations and aging conditions typically found in such applications. Ultrafast compression is useful to characterize polymer shock response over a wide range of polymer initial conditions due to the high throughput of this method. To establish greater confidence in ultrafast compression experiments and to characterize the detailed shock response of several variations in a single base polymer, the results of sub–nanosecond shock compression experiments in ~5 μm thick layers of the polydimethylsiloxane (PDMS)–based elastomeric rubbers Sylgard–184, SE1700, and an unfilled, end–linked model PDMS network are presented. The results of conventional ultrafast shock etalon measurements to time–of–flight measurements for similar thickness layers of irradiated and unirradiated SE1700 are compared. Here, good agreement between the shock response measured by these two ultrafast shock methods, as well as consistency between ultrafast data and long time scale gas gun data is found.

36 MATERIALS SCIENCE↗

A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system]

Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.

42 ENGINEERING↗

Topics in LIFE Target Survival: 11-SI-004 Final Report

The LIFE target design incorporates many considerations to generate the desired fusion gain including the physics design, the cost of manufacturing of the target, the injectability of the target, the aerodynamic flight characteristics of the target, the ability to track and engage the target and to maintain the structural and thermal integrity of the target. This document describes the effort that was made in support of issues of survivability of the target during injection which included issues massmanufactural materials and processes which could be used in the target.

42 ENGINEERING↗

System of fabricating a flexible electrode array

An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

60 APPLIED LIFE SCIENCES↗

System of fabricating a flexible electrode array

An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

Krulevitch, Peter↗

Polymer-based platform for microfluidic systems

A method of forming a polymer-based microfluidic system platform using network building blocks selected from a set of interconnectable network building blocks, such as wire, pins, blocks, and interconnects. The selected building blocks are interconnectably assembled and fixedly positioned in precise positions in a mold cavity of a mold frame to construct a three-dimensional model construction of a microfluidic flow path network preferably having meso-scale dimensions. A hardenable liquid, such as poly (dimethylsiloxane) is then introduced into the mold cavity and hardened to form a platform structure as well as to mold the microfluidic flow path network having channels, reservoirs and ports. Pre-fabricated elbows, T's and other joints are used to interconnect various building block elements together. After hardening the liquid the building blocks are removed from the platform structure to make available the channels, cavities and ports within the platform structure. Microdevices may be embedded within the cast polymer-based platform, or bonded to the platform structure subsequent to molding, to create an integrated microfluidic system. In this manner, the new microfluidic platform is versatile and capable of quickly generating prototype systems, and could easily be adapted to a manufacturing setting.

42 ENGINEERING↗