The Space Infrared Interferometric Telescope (SPIRIT): High-resolution Imaging and Spectroscopy in the Far-infrared

We report results of a recently-completed study of SPIRIT, a candidate NASA Origins Probe. SPIRIT is a spatial and spectral interferometer with an operating wavelength range 25 - 400 microns. SPIRIT will provide sub-arcsecond resolution images and spectra with resolution R = 3000 in a 1 arcmin field of view to accomplish three primary scientific objectives: (1) Learn how planetary systems form from protostellar disks, and how they acquire their chemical organization; (2) Characterize the family of extrasolar planetary systems by imaging the structure in debris disks to understand how and where planets form, and why some planets are ice giants and others are rocky; and (3) Learn how high-redshift galaxies formed and merged to form the present-day population of galaxies. Observations with SPIRIT will be complementary to those of the James Webb Space Telescope and the ground-based Atacama Large Millimeter Array. All three observatories could be operational contemporaneously. SPIRIT will pave the way to the 1 km maximum baseline interferometer known as the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS). In addition to the SPIRIT mission concept, this talk will emphasize the importance of dense u-v plane coverage and describe some of the practical considerations associated with alternative interferometric baseline sampling schemes.

Leisawitz, D,↗

Variations on the Davenport Gyroscope Calibration Algorithm

This paper presents a number of variations on the Davenport algorithm for in-flight gyroscope recalibration, or first order initial calibration, specifically tailored for use with a minimum of satellite telemetry data. Central to one of the techniques described is the use of onboard integration of gyroscope data together with a detailed model of scheduled satellite slew profiles. Methods are presented for determining adjustments to either parameters for the standard linear model (i.e., a drift rate bias vector and/or a scale factor/alignment transformation matrix) or individual gyroscope scale parameters, both linear and nonlinear, in cases where the alignments are well known. The results of applying the methods in an analysis of the temporal evolution and nonlinear response of the gyroscopes installed on the Hubble Space Telescope following its first servicing mission are discussed. The two effects, when working coherently, have been found to result in slew errors of almost 1 arcsecond per degree. Procedures for selecting optimal operational gyroscope parameters subject to the constraint of using a linear model are discussed.

Welter, G.↗

In-flight scale/distortion calibration of the Hubble Space Telescope fixed-head star trackers

This paper describes an in-flight scale and distortion calibration procedure that has been developed for the Ball Aerospace Systems Division Fixed-Head Star Trackers (FHST's) used on the Hubble Space Telescope (HST). The FHST is a magnetically focused and deflected imaging sensor that is designed to track stars as faint as m(sub v) = 5.7 over an 8 degree by 8 degree field of view. Raw FHST position measurements are accurate to approximately 200 arcseconds, but this can be improved to 10-15 arcseconds by processing the raw measurements through calibration polynomials that correct for flat field, temperature intensity, and magnetic field effects. The coefficients for these polynomials were initially determined using ground test data. On HST the use of three FHST's is an integral part of the preliminary attitude update procedures required before the acquisition of guide stars for science observations. To this end, FHST-based attitude determination having single-axis errors no worse than 22 arcseconds (1 sigma) is required. In early 1991 it became evident that one of the HST FHST's was experiencing a significant change in its optical scale. By mid-1993 the size of this error had grown to a point that, if not corrected, it would correspond to a maximum position error on the order of 100 arcseconds. Subsequent investigations demonstrated that substantial, uncompensated cubic distortion effects had also developed, the maximum contribution to position errors from the cubic terms being on the order of 30 arcseconds. To ensure accurate FHST-based attitude updates, procedures have been developed to redetermine the FHST scale and distortion calibration coefficients based on in-flight data gathered during normal HST operations. These scale and distortion calibrations have proven very effective operationally, and procedures are in place to monitor FHST calibration changes on a continuing basis.

Mccutcheon, R.↗

The in-flight calibration of the Hubble Space Telescope fine guidance sensors, 2 (a success story)

The Hubble Space Telescope's fine guidance sensors (FGS's) are unique in the performance levels being attempted; spacecraft control and astrometric research with accuracies better than 3 milli-arcseconds (mas) are the ultimate goals. This paper presents a review of the in-flight calibration of the sensors, describing both the algorithms used and the results achieved to date. The work was done primarily in support of engineering operations related to spacecraft pointing and control and secondarily in support of the astrometric science calibration effort led by the Space Telescope Astrometry Team. Calibration items of principal interest are distortion, sensor magnification, and relative alignment. An initial in-flight calibration of the FGS's was performed in December 1990; this calibration has been used operationally over the past few years. Followup work demonstrated that significant, unexpected temporal variations in the calibration parameters are occurring; provided good characterization of the variation; and set the stage for a distortion calibration designed to achieve the full design accuracy for one of the FGS's. This full distortion calibration, using data acquired in January 1993, resulted in a solution having single-axis residuals with a standard deviation of 2.5 mas. Scale and alignment calibration results for all of the FGS's have been achieved commensurate with the best ground-based astrometric catalogs (root-mean-square error approximately 25 mas). A calibration monitoring program has been established to allow regular updates of the calibration parameters as needed.

Welter, Gary L.↗

The in-flight calibration of the Hubble Space Telescope fine guidance sensors

The Hubble Space Telescope (HST) fine guidance sensors are unique in the precision and performance levels being attempted; spacecraft control and astrometric research at the near milliarcsecond level are the ultimate goals. The inflight calibration of the sensors is presented, describing both the algorithms being used as well as the results achieved to date. The calibration items of principal interest are optical distortion, sensor magnification, and relative alignments. Calibration accuracies at the 20 milliarcsecond level have been achieved for specific data sets for optical distortion parameters. Unexpected variations occurring from Dec. 1990 - May 1991 in the magnification and alignment parameters are currently under investigation. Plans are being developed for new data acquisitions and reductions that should substantially improve HST pointing performance.

Welter, G. L.↗

The optical field angle distortion calibration feasibility study for the Hubble Space Telescope fine guidance sensors

The results of an analytical study to investigate the feasibility of calibrating the Hubble Space Telescope's (HST's) fine guidance sensors (FGSs) within HST mission accuracy limits are presented. The study has two purposes: (1) to determine the mathematical feasibility of the optical field angle distortion (OFAD) calibration algorithm and (2) to confirm that the OFAD, plate scale, and FGS-to-FGS alignment calibration algorithms produced a calibration of the FGSs that satisfied mission requirements. The study concluded that the mathematical specification of the OFAD algorithm is adequate and permits a determination of the FGS calibration parameters (accurate to better than 0.003 arc-second) sufficient to meet the mission requirements. The algorithms implemented, the characteristics of the simulated data and procedures for data analysis, and the study's results are discussed. In addition, several useful techniques for improving the stability and accuracy of the OFAD solution are outlined.

Luchetti, K.↗