Engineering PapersSearch

Engineering topics

Hallam, K. L.

Publications and source records attributed to Hallam, K. L..

At least 19 records

Rotational modulation in IUE spectra of cool dwarf chromospheres. I - Data analysis and period search techniques

Time-sequenced IUE spectra of a number of a bright F-K dwarfs have been used to investigate rotational modulation in several important chromospheric and transition emission lines. Stellingwerf's phase dispersion minimization (PDM) technique forms the basis of this time-series analysis of these sparsely sampled, irregularly spaced observational sequences, which consist of no more than 13 spectra in any one season. In such highly sample-limited time series, the resultant PDM spectrum is greatly complicated by overlapping alias orders which invariably produce strong interference effects, but the deliberately irregular sampling has proven of value in the development of techniques to identify the intrinsic stellar flux modulation period. Two stars are selected to illustrate these new techniques in detail.

Hallam, K. L.

Wide-Angle, Flat-Field Telescope

All-reflective system unvignetted. Wide-angle telescope uses unobstructed reflecting elements to produce flat image. No refracting elements, no chromatic aberration, and telescope operates over spectral range from infrared to far ultraviolet. Telescope used with such image detectors as photographic firm, vidicons, and solid-state image arrays.

Hallam, K. L.

Rotational modulation in IUE spectra of cool dwarf chromospheres: Data analysis and period search techniques

The IUE spectra of bright F-K dwarfs were used to investigate rotational modulation in chromospheric and transition region emission lines, with Stellingwerf's phase dispersion minimization (PDM) technique as the basis of time series analysis. Sampling-related aliases are found to dominate the PDM spectra in these sparsely sampled, irregularly spaced time series. The star chosen to illustrate the techniques is epsilon Eridani, a young, chromospherically active K2 dwarf. Strong indications of a rotation period close to 2.8 days in epsilon Eridani from 2 seasons of observations, with evidence for the persistence in longitude of the active area(s) over several hundred rotation cycles are found.

Altner, B.

Wide-angle flat field telescope

Described is an unobscured three mirror wide angle telescopic imaging system comprised of an input baffle which provides a 20 deg (Y axis) x 30 deg (X axis) field of view, a primary mirror having a convex spherical surface, a secondary mirror having a concave ellipsoidal reflecting surface, a tertiary mirror having a concave spherical reflecting surface. The mirrors comprise mirror elements which are offset segments of parent mirrors whose axes and vertices commonly lie on the system's optical axis. An iris diaphragm forming an aperture stop is located between the secondary and tertiary mirror with its center also being coincident with the optical axis and being further located at the beam waist of input light beams reflected from the primary and secondary mirror surfaces. At the system focus following the tertiary mirror is located a flat detector which may be, for example, a TV imaging tube or a photographic film. When desirable, a spectral transmission filter is placed in front of the detector in close proximity thereto.

Hallam, K. L.

An all-reflective wide-angle flat-field telescope for space

An all-reflective wide-angle flat-field telescope (WAFFT) designed and built at Goddard Space Flight Center demonstrates the markedly improved wide-angle imaging capability which can be achieved with a design based on a recently announced class of unobscured 3-mirror optical systems. Astronomy and earth observation missions in space dictate the necessity or preference for wide-angle all-reflective systems which can provide UV through IR wavelength coverage and tolerate the space environment. An initial prototype unit has been designed to meet imaging requirements suitable for monitoring the ultraviolet sky from space. The unobscured f/4, 36 mm efl system achieves a full 20 x 30 deg field of view with resolution over a flat focal surface that is well matched for use with advanced ultraviolet image array detectors. Aspects of the design and fabrication approach, which have especially important bearing on the system solution, are reviewed; and test results are compared with the analytic performance predictions. Other possible applications of the WAFFT class of imaging system are briefly discussed. The exceptional wide-angle, high quality resolution, and very wide spectral coverage of the WAFFT-type optical system could make it a very important tool for future space research.

Hallam, K. L.

Synoptic studies of chromospheric variability in F - K dwarfs with the IUE

Time-sequential series of IUE spectra for ten F, G and K dwarfs were obtained in 1980 and 1981 to study the rotational dependence of chromospheric flux in the ultraviolet. An interactive computational method using unbiased estimators was developed to measure emission line fluxes free of arbitrary judgement concerning the behavior of the underlying spectrum and shapes of the line profiles. Due to the limited number of observational samples per star, we have used special techniques to analyze the sparsely and anharmonically sampled emission line flux data. Two different autocorrelation measures were computed for each emission line as a function of temporal frequency. Examples and results of this analysis now in progress are given for several stars.

Hallam, K. L.

Rotation of dwarf star chromospheres in the ultraviolet

Periodic variations in the ultraviolet fluxes of chromospheric emission line multiplets are investigated for F, G and K stars as evidence of rotational modulation. Vacuum ultraviolet spectra were obtained with the IUE spacecraft for six stars as many as 11 times over the period April 23 to December 3, 1980. Variations in the emission fluxes of the hydrogen Lyman-alpha, Si II and Mg II lines are observed with periods up to 47 days. The periodicity, which is identified with rotational modulation, is found to persist over many rotational cycles, although the periods and time dependences of the fluxes from the different ionic species are not identical, probably due to differential rotation and global distributions. The spread of the UV periods is observed to be within 10%, with one or two peaks per cycle and a ratio of modulated to umodulated flux ranging from 1.1 to 3.0, analogous to solar behavior.

Hallam, K. L.

Imaging of X-ray aurorae from Spacelab

The Atmospheric X-ray Emission Telescope (AXET) is designed to image and measure the spatial, temporal, and spectral distributions of X-ray aurorae produced in the upper atmosphere by precipitating energetic electrons. The bremsstrahlung-produced X radiation penetrates to stratospheric depths where it can modify ozone, conductivity, and other critical atmospheric parameters. Remote sensing of this radiation from topside will provide vital data on solar-terrestrial relationships and mechanisms that could help trigger tropospheric response to solar activity. The X rays also provide direct information concerning the dynamics of radiation-belt processes within the magnetosphere. AXET is designed to detect sources up to 50 keV and to image them below 25 keV by means of directionally sensitive proportional counters with passive collimators. It will be mounted in the Space Shuttle on a single fixed platform designed to optimize viewing conditions for the anticipated orbits and aspects of early Spacelab missions.

Goldberg, R. A.

X-ray sensitive oblique imaging device

Instrument employs light reflecting surface (evaporated aluminum coating or minor substrate) behind phosphor screen to improve effective quantum efficiency in dual process: fraction of incoming X-rays are converted to photoelectrons at photocathode; and X-rays that pass through photocathode and thin X-ray transparent membrane enter phosphor screen.

Hallam, K. L.

Monochromatic observations of Comet Tago-Sato-Kosaka 1969g /1969IX/

Isophotes have been determined from 10 narrow-band filter photographs of Comet Tago-Sato-Kosaka 1969g (1969IX) taken between Feb. 11 and 14, 1970. The five interference filters used were centered on the CN band sequence at 3383A, the C2 band sequence at 4737A and 5165A, the C3 sequence at 4050A, and the continuum at 5300A. Gradients of intensity in various directions from the nucleus have been derived from the isophotes.

Rahe, J.

Atmospheric X-ray emission experiment for shuttle

An experiment designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons, is presented. The experiment will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. An instrument concept is discussed, and is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. An instrument pointing system, on which the counter can be mounted, will provide the required altitude control, and can be operated by a Spacelab payload specialist for full control over its observing and data taking modes.

Goldberg, R. A.

Atmospheric X-ray Emission Experiment for Shuttle

The Atmospheric X-ray Emission Experiment (AXEE) for Shuttle is designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons. It will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. The instrument concept is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. It will be mounted on an instrument pointing system to provide the required attitude control and is operated by the Spacelab payload specialist who has full control over its observing and data taking modes.

Goldberg, R. A.

Image tube

An optical image is projected onto a planar surface of a photocathode that derives an electron beam replica of the image. A target electrode displaced relative to the photocathode so that it does not obstruct the optical image includes a planar surface for receiving and deriving an accurate replica of the electron beam image. The two planar surfaces are parallel. The electron beam image is focused on the target electrode by providing throughout a region that extends between the planar surfaces of the photocathode and receiving electrode, constant homogeneous dc electric and magnetic fields. The electric field extends in a direction perpendicular to the planar surfaces while the magnetic field extends along a straight line that intersects the photocathode and target electrode at an acute angle.

Hallam, K. L.

A magnetically focused image tube employing an opaque photocathode

Image converter has been developed which uses opaque photocathode for improved efficiency. Device is easier to fabricate than previous semi-transparent photocathode converters and uses compounds from Groups 3-5 that are responsive to wave-lengths between ultraviolet (approximately 100 nm) and near infrared region (approximately 1000 nm).

Johnson, C. B.

The oblique electron lens.

An oblique electron lens is described that is especially applicable to image converters and camera tubes employing flat opaque photocathodes. The use of optical lenses, corrector plates, and/or mirrors (often employed in other electron lenses designed for use with opaque photocathodes) are eliminated. The oblique electron lens is well suited to ultraviolet and vacuum ultraviolet image converters, and to image converters employing opaque negative electron affinity photocathodes. It is also possible to use this oblique electron lens for electronography. Measurements on an experimental tube show that a limiting resolution of 50 line pairs/mm is possible, but the intrinsic lens quality is believed to approach that of a conventional electromagnetic lens having uniform and colinear electric and magnetic fields.

Johnson, C. B.

An electron-lens for opaque photocathodes.

It is possible to employ opaque photocathodes in image tubes having a special electromagnetic lens without the use of special internal image-forming optical lenses or mirrors. The special electron lens, having flat object and image planes, is found to provide excellent quality electron-optical image transfer. Stray light reflection inside the tube is expected to be less serious in this electron lens than in a conventional magnetically focused image tube lens due to the offset image plane, and due to the increased absorption of photons in opaque photocathode applications.

Johnson, C. B.

A study of optical image sensors for the large space telescope.

A generalized approach is attempted to the problem of designing an image sensor that is to be used on a large spaceborne telescope. General design and performance goals are presented, and the parameters describing the sensor characteristics are discussed. Electrooptical techniques and components presently available are reviewed, and promising design orientations are explored.

Hallam, K. L.