Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

Characterization of Spent Purolite A530E Resin with Implications for Long-Term Radioactive Contaminant Removal

Direct removal of pertechnetate anion (TcO4-) from the subsurface contaminated plumes at legacy nuclear weapons production sites, is effective remediation strategy to prevent their spread to adjacent aquifers but is also challenging because TcO4- is a trace component of the contaminated groundwater typically containing large access of other anionic constituents, such nitrate, sulfate, chloride and others. It can be achieved through ion exchange treatment using Purolite A530E resin which to date however has only been evaluated under laboratory conditions and many questions regarding its long-term operational performance remain. To address this need, here we report comprehensive characterization of the spent Purolite A530E resin which processed over 5.38x109 L of contaminated groundwater and successfully removed about 3.78 Ci of Tc-99 during four years of operation at the 200 West Pump & Treat facility at the US DOE Hanford site. This Tc-99 loading constitutes however only about 0.034% of the theoretical capacity of the resin which retained significant amounts of sulfate. Among other radioactive contaminants, small quantities of U-238, Co-60, and I-129 were retained by the resin. The total loading of iodine (combined 1-127 and I-129) on the spent resin exceeded that of Tc-99. To elucidate the mechanism of iodine retention, ion exchange behavior of iodide and iodate was investigated. Purolite A530E resin exhibited highly efficient uptake of iodide and only moderate affinity for iodate in accord with their Gibbs energy of hydration. Sorption isotherms for both anions obeyed Freundlich model.

Levitskaia, Tatiana G.↗

CoDCon Project (Final Report)

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet, and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We were interested in assessing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project was set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio was investigated during five flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques were incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were performed in FY 2018 using a simple dissolved fuel simulant containing only U (~1 M) and Pu (~15 mM) in nitric acid (HNO 3 ; ~3 M). In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. A fifth CoDCon flowsheet test (CoDCon Run 5) was conducted in FY 2020, with the following additional objectives: (1) routing of the technetium (Tc) in the simulated dissolved fuel solution to the solvent extraction raffinate, and (2) routing of the Np in the simulated dissolved fuel solution to the U/Pu product. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu (and Np, for Run 5), then the Pu (and Np) was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product. This report presents the results of the CoDCon Run 5 test. The flowsheet tested in Run 5 was substantially different than that run in the prior tests, especially the solvent loading section of the flowsheet. Two key changes were made. First, based on the objective to extract all the Np and route it with the U/Pu product, pentavalent vanadium [V(V)] was added to the feed and scrub solutions. The purpose of the V(V) was to convert all the Np to the +6 oxidation state, which is extractable by TBP. Second, a high acid (8 M HNO 3 ) scrub was added to the flowsheet to scrub the Tc from the solvent. This was followed by a low acid scrub (0.05 M HNO 3 ) to reduce the residual HNO 3 concentration in the solvent prior to the Pu stripping step. The output from the low acid scrub was collected separately, rather than routing towards the raffinate. The modifications to the solvent loading part of the flowsheet were only partially successful. The treatment with V(V) was effective at converting the Np to Np(VI). Only 1.3% of the Np remained in the raffinate solution. However, ~40% of the Np stripped out of the solvent in the low acid scrub step; nearly 20% of the Pu also was stripped from the solvent during the low acid scrub. For further development, either modifications to the flowsheet, or concentration and recycle of the low acid stream into the

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensor Fusion: Comprehensive Real-Time, On-Line Monitoring for Process Control via Visible, Near-Infrared, and Raman Spectroscopy

On-line monitoring based on optical spectroscopy provides unprecedented insight into the chemical composition of process streams or batches. Amplifying this approach through utilizing multiple forms of optical spectroscopy in sensor fusion can greatly expand the number and type of chemical species that can be identified and quantified. This is demonstrated herein, on the analysis of used nuclear fuel recycling streams: highly complex processes with multiple target and interfering analytes. The optical techniques of visible absorbance, near infrared absorbance, and Raman spectroscopy were combined to quantify plutonium (III, IV, VI), uranium (IV, VI), neptunium (IV, V, VI), and nitric acid. Chemometric modeling was used to quantify analytes in process streams in real-time and results were successfully used to enable immediate process control and generation of a product stream at a set composition ratio. This represents a significant step forward in the ability to monitor and control complex chemical processes occurring in harsh chemical environments.

47 OTHER INSTRUMENTATION↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Overcoming Oxidation State-Dependent Spectral Interferences: Online Monitoring of U(VI) Reduction to U(IV) via Raman and UV–vis Spectroscopy

Analytical characterization of chemical processes is an essential component of both industrial processes and fundamental studies. Applicable techniques abound, but optical spectroscopy has the unique combination of being easily incorporated into on-line (in-situ) monitoring probes and can also provide abundant chemical information (concentration, oxidation state, speciation). However, this abundance of chemical information can make applying optical spectroscopy to complex chemical processes challenging. This is particularly evident in the bulk electrolysis of U(VI) to U(IV), an essential preparatory step in some nuclear fuel recycling schemes. Starting and product materials have interfering spectral signatures in both electronic and vibrational spectroscopies, making accurate and real-time analysis difficult to achieve. In this paper, we discuss the application of optical spectroscopy to the on-line monitoring of a bulk electrolysis process and the methods utilized to analyze data as well as characterize the efficiency and mechanism of U(IV) generation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

Closing the Nuclear Fuel Cycle with a Simplified Minor Actinide Lanthanide Separation Process (ALSEP) and Additive Manufacturing

Expanded low-carbon baseload power production through the use of nuclear fission can be enabled by recycling long-lived actinide isotopes within the nuclear fuel cycle. This approach provides the benefits of (a) more completely utilizing the energy potential of mined uranium, (b) reducing the footprint of nuclear geological repositories, and (c) reducing the time required for the radiotoxicity of the disposed waste to decrease to the level of uranium ore from one hundred thousand years to a few hundred years. A key step in achieving this goal is the separation of long-lived isotopes of americium (Am) and curium (Cm) for recycle into fast reactors. To achieve this goal, a novel process was successfully demonstrated on a laboratory scale using a bank of 1.25-cm centrifugal contactors, fabricated by additive manufacturing, and a simulant containing the major fission product elements. Americium and Cm were separated from the lanthanides with over 99.9% completion. The sum of the impurities of the Am/Cm product stream using the simulated raffinate was found to be 3.2 × 10 –3 g/L. The process performance was validated using a genuine high burnup used nuclear fuel raffinate in a batch regime. Separation factors of nearly 100 for 154 Eu over 241 Am were achieved. All these results indicate the process scalability to an engineering scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CoDCon Project: FY 2019 Status Report

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We are interested in establishing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project is set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio is being established through multiple flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques have been incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were successfully performed in FY 2018. In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu, then the Pu was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulant Testing of a Co-Decontamination (CoDCon) Flowsheet for a Product with a Controlled Uranium-to-Plutonium Ratio

Multiple tests of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet are being performed to determine the uncertainties associated with maintaining a target U/Pu ratio in the Pu-containing product. The first two flowsheet tests used simple dissolved fuel simulants containing only U and Pu, but increasingly more complex simulants will but used in subsequent tests, with the ultimate goal of performing tests with irradiated fuel. The flowsheet is designed so as not to create a purified Pu stream, but rather a mixture of U and Pu with a U/Pu mass ratio of 7/3. Uranium and Pu are first co-extracted into the TBP solvent, and then U(IV) is used to strip the Pu from the loaded solvent. A fresh TBP solvent stream is introduced at the same stage the Pu-containing aqueous stream exits. The flowrate of the fresh TBP solvent stream is adjusted so that sufficient U bleeds over into the Pu product to produce the desired U/Pu ratio. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio through adjustment of the fresh TBP solvent flowrate. This paper will describe the results of the first two CoDCon flowsheet tests.

CoDCon, fuel recycle, fuel reprocessing, on-line m↗

Vitrification of Hanford Tank Waste 241-AP-107 in a Continuous Laboratory-Scale Melter

Low-activity waste (LAW) stored in underground tanks on the Hanford Site in Washington State is planned to be filtered for solids removal and processed through ion exchange columns for cesium removal. These pretreatment steps will allow the waste to be transferred to the Hanford Tank Waste Treatment and Immobilization Plant’s LAW Facility for immobilization into glass. The liquid waste will be combined with glass-forming chemicals (GFCs) to form a waste feed slurry that can be fed to electric melters for vitrification. The process of continuously converting the aqueous feed slurry into a melt is dynamic and includes multiple reactions, degassing, and dissolution processes that depend on heat from the melt below. In this conversion process, waste components are partitioned into one of two streams: glass and off-gas. Washington River Protection Solutions has requested processing information and chemical information associated with these waste products for actual waste from Hanford tank 241-AP-107 (referred to herein as AP-107). To acquire this type of information, a small-scale melter system was designed that would not require high volumes of input waste or the large resource commitment of a full-scale melter system, while also providing dynamic information that would be difficult to determine from batch reactions in a crucible system. A continuous laboratory-scale melter (CLSM) has been designed to operate with a continuous feeding process while periodically pouring glass product and collecting off-gas. The CLSM vessel has been sized to collect the relevant process and chemical information from obtainable volumes of AP-107 waste samples. A total 8.6 L of actual AP-107 tank waste were received after filtering for solids removal and ion exchange for cesium removal. This volume of AP-107 waste was mixed with GFCs to form an estimated 11.8 L of melter feed slurry. A mass of 7.01 kg of glass product were poured from the CLSM vessel during 10.07 hours of charging the AP-107 melter feed, indicating that about 15.0 kg of melter feed was vitrified into glass. The CLSM system was also designed with the capability to fully divert the flow of off-gas produced in the CLSM vessel to a sampling line that could capture the volatile species of interest, such as technetium-99 ( 99 Tc). This novel sampling system avoided the difficulties of slipstream sampling and could be activated once the feeding reached a steady state within the CLSM vessel. Off-gas product samples captured via high-efficiency particulate air (HEPA) filters using this method, as well as selected glass product samples were sent to an analytical lab for chemical analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction Behavior of Ln(III) ions by T2EHDGA/n-dodecane from Nitric acid and Sodium Nitrate Solutions

The diglycolamide extractant, T2EHDGA, has proven promising for the separation of lanthanides and minor actinides in high-level nuclear waste reprocessing. This neutral extractant has shown significant extraction capacity for HNO3 into the non-polar organic phase, along with hyper-stoichiometric nitrate dependence on extraction of trivalent f-elements. The transport behavior of T2EHDGA/n-dodecane toward trivalent lanthanides is not well understood. This work found a significant increase in distribution measurements for Eu(III) extracted from aqueous HNO3 media as compared to NaNO3. The extraction of Eu(III) from HNO3 results in a different thermodynamic product than predicted by classic solvent extraction of 3:1 ligand-metal complex as observed with NaNO3 in FTIR and UV-vis spectroscopy. Experimental distribution measurements in conjunction with the solvent extraction modeling program, SXLSQI, suggest participation of 1- to 2 HNO3 molecules in the Eu(III)/T2EHDGA complex when extracted from HNO3 media, indicative of a mechanism change responsible for the enhanced extraction behavior toward lanthanides in the presence of HNO3.

Campbell, Emily L.↗

Analysis of Uranium Ion Exchange Resin from the 200 West Pump-and-Treat Facility

The 200 West Area Pump-and-Treat (P&T) Facility at the Hanford Site is a multifunctional groundwater treatment facility consisting of unit processes to remove radionuclides such as uranium (U) and technetium (Tc-99) as well as other inorganic (nitrate and hexavalent chromium), and organic (carbon tetrachloride and trichloroethene) contaminants. The RAD building of the P&T Facility removes U and Tc-99 using ion exchange chromatography. In 2016, the Purolite A530E resin used for the Tc-99 removal was replaced and the spent resin was analyzed. In addition to Tc-99, the Purolite A530E resin also retained I-129 and Co-60; however, the resin loading was dominated by common groundwater constituents such as calcium, iron, silicon, and sulfate.

54 ENVIRONMENTAL SCIENCES↗

Vitrification of Hanford Tank Waste 241-AP-105 in a Continuous Laboratory-Scale Melter

Low-activity waste (LAW) stored in underground tanks on the Hanford site in Washington State is planned to be filtered for solids removal and processed through ion exchange columns for cesium removal at the Low-Activity Waste Pretreatment System facility. These pretreatment steps will allow the waste to be transferred to the Hanford Tank Waste Treatment and Immobilization Plant LAW facility for immobilization into glass. The liquid waste will be combined with glass-forming chemicals (GFCs) to form a waste feed slurry that can be fed to electric melters for vitrification. The process of continuously converting the aqueous feed slurry into a melt is dynamic and includes multiple reactions, degassing, and dissolution processes that depend on heat from the melt below. In this conversion process, waste components are partitioned into one of two streams: glass and off-gas. Processing information and chemical information associated with these waste product streams has been requested by Washington River Protection Solutions for actual tank waste from tank 241-AP-105 (referred to as AP-105). To acquire this type of information, a small-scale melter system was desired that would not require high volumes of input waste or the large resource commitment of a full-scale melter system, while also providing dynamic information that would be difficult to determine from batch reactions in a crucible system. A continuous laboratory-scale melter (CLSM), has been designed to operate with a continuous feeding process, while periodically pouring glass product and collecting off-gas. The CLSM vessel has been sized to collect the relevant process and chemical information from obtainable volumes of AP-105 waste samples. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. This dual-system setup allowed for comparison between simulated and real tank waste with essentially identical test equipment. AP-105 waste simulant was first tested in the non-radioactive CLSM to determine the processability and desired operating window for the actual tank waste. Rhenium (Re) was added to the simulant to act as a surrogate for technetium-99 ( 99 Tc), a key waste component found in the actual tank waste. The partitioning of Re into the glass and off-gas products during the continuous feeding of simulant was determined, which allowed the Re retention, the mass flow rate of Re out of the CLSM via the glass product with respect to the mass flow rate of Re into the CLSM via the feed slurry, to be calculated. Key processing results and the average Re retention, from the CLSM test run with AP-105 simulant feed slurry are shown in Table ES.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spectroscopic Characterization of Aqua [ fac -Tc(CO) 3 ] + Complexes at High Ionic Strength

Understanding fundamental Tc chemistry is important to both the remediation of nuclear waste and the reprocessing of nuclear fuel; however, current knowledge of the electronic structure and spectral signatures of low-valent Tc compounds significantly lags behind the remainder of the d-block elements. In particular, identification and treatment of Tc speciation in legacy nuclear waste is challenging due to the lack of reference data especially for Tc compounds in the less common oxidation states (I–VI). In an effort to establish a spectroscopic library corresponding to the relevant conditions of extremely high ionic strength typical for the legacy nuclear waste, compounds with the general formula of [ fac -Tc(CO) 3 (OH 2 ) 3– n (OH) n ] 1– n (where n = 0–3) were examined by a range of spectroscopic techniques including 99 Tc/ 13 C NMR, IR, XPS, and XAS. In the series of monomeric aqua species, stepwise hydrolysis results in the increase of the Tc metal center electron density and corresponding progressive decrease of the Tc–C bond distances, Tc electron binding energies, and carbonyl stretching frequencies in the order [ fac -Tc(CO) 3 (OH 2 ) 3 ] > [ fac -Tc(CO) 3 (OH 2 ) 2 (OH)] > [ fac -Tc(CO) 3 (OH 2 )(OH) 2 ] – . These results correlate with established trends of the 99 Tc upfield chemical shift and carbonyl 13 C downfield chemical shift. The lone exception is [ fac -Tc(CO) 3 (OH)] 4 which exhibits a comparatively low electron density at the metal center attributed to the μ 3 -bridging nature of the –OH ligands causing less σ-donation and no π-donation. As a result, this work also reports the first observations of these compounds by XPS and [ fac -Tc(CO) 3 Cl 3 ] 2– by XAS. The unique and distinguishable spectral features of the aqua [ fac -Tc(CO) 3 ] + complexes lay the foundation for their identification in the complex aqueous matrixes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inorganic Ba-Sn Nanocomposite Materials for Sulfate Sequestration from Complex Aqueous Solutions

Selective sequestration of sulfate (SO42-) in the form of barite (BaSO4) from alkaline solutions of high ionic strength containing carbonate at high concentrations resembling legacy radioactive waste generated during plutonium cold war era production is problematic due to the preferential formation of BaCO3. Incorporation of sulfate into the insoluble and thermally stable BaSO4 phase can potentially benefit radioactive waste processing in reducing operational challenges and suppressing volatilization of other waste components such as technetium-99. To enhance selectivity of SO42- sequestration, a series of Ba(II)-Sn(IV) materials was prepared using simple hydrothermal synthesis from different Sn(II) and Sn(IV) precursors. Structural characterization indicated that all obtained products predominantly contained BaSn(OH)6 and Ba2SnO2(OH)4(H2O)10 crystalline phases which were disrupted upon exposure to SO42- due to formation of BaSO4. Performance of the Ba(II)-Sn(IV) materials was tested using complex alkaline solutions simulating radioactive waste containing 0.094 M SO42- and 0.5 M CO32- among other constituents. About 54 – 66% of SO42- was converted to BaSO4 when a quantity of Ba(II)-Sn(IV) material containing approximately a stoichiometric amount of Ba2+ relative to SO42- was used. In comparison, previous studies indicate negligible BaSO4 formation under similar conditions when a simple Ba2+ salt is used. This improvement is attributed to the selective replacement of the Ba(II) stannate by SO42-. Thermal stability of the sulfate-loaded product material up to 1100 °C was demonstrated. Obtained materials offer a convenient and economical option for the selective sequestration or removal of SO42- from carbonate containing solutions.

Johnson, Isaac↗