Engineering Papers⌕ Search

Engineering topics

Haines, R. F.

Publications and source records attributed to Haines, R. F..

At least 37 records · Page 2

A preliminary study of head-up display assessment techniques. 2: HUD symbology and panel information search time

Twelve commercial pilots were shown 50 high-fidelity slides of a standard aircraft instrument panel with the airspeed, altitude, ADI, VSI, and RMI needles in various realistic orientations. Fifty slides showing an integrated head-up display (HUD) symbology containing an equivalent number of flight parameters as above (with flight path replacing VSI) were also shown. Each subject was told what flight parameter to search for just before each slide was exposed and was given as long as needed (12 sec maximum) to respond by verbalizing the parameter's displayed value. The results for the 100-percent correct data indicated that: there was no significant difference in mean reaction time (averaged across all five flight parameters) between the instrument panel and HUD slides; and a statistically significant difference in mean reaction time was found in responding to different flight parameters.

Guercio, J. G.↗

Project plan for joint FAA/NASA head-up display concept evaluation

Head-Up Display (HUD) concept for large commercial turbojet transport aircraft is considered for the its contribution to aviation safety in the form of improved performance during the approach and landing phase flight. The basic reearch areas represent fundamental questions that are still unresolved and which were considered important to the effective use of the HUD by pilots. Project documentation and management responsibilities are outlined.

Haines, R. F.↗

Preliminary study of head-up assessment techniques. 1: Viewing duration of instrument panel and HUD symbology using a recall methodology

Eight commercial pilots were shown 50 colored, high fidelity slides of a standard instrument panel (IP) with the needle positions of each instrument varying from slide to slide and then 50 slides of a head-up display (HUD) symbology format which contained an equivalent amount of flight-related information as the instrument panel slides. All stimuli were presented under controlled, static viewing conditions that allowed the measurement of the speed and accuracy with which one randomly selected flight parameter on each slide could be read. The subject did not know which parameter would be requested and, therefore, had to remember the total set of information in order to answer the question correctly. The results showed that from 6.6 - 8.7 sec total viewing time was required to correctly extract altitude, airspeed, heading, VSI, or ADI from the IP slides and from 6.1 to 7.4 sec for the HUD slides.

Haines, R. F.↗

A layout designer's data projection reticle

The designer's projection reticle is a modified surplus weapons sighting device consisting of a 3.5 cm diameter, 8.9 focal length coated objective lens. It is placed 1.5 cm in front of a clear flat glass plate on which the aluminized reflective pattern has been deposited. Reflected light passes through the objective lens, off the front surface of the coating, and off the rear coated surface of the objective lens. Several reticle patterns have been designed and tested, and other patterns are in the planning stage. The device may be used for a variety of applications including determining the optimum locations on a cockpit panel for luminous warning indicators requiring rapid manual responses.

Haines, R. F.↗

Effect of hypovolemia, infusion, and oral rehydration on plasma electrolytes, ADH, renin activity, and +G/z/ tolerance

Effects on plasma volume, electrolyte shifts, and +G(z) tolerance induced by: (1) blood withdrawal; (2) blood infusion; and (3) oral fluid intake, were determined at 0.5 G/min in centrifugation tests of six ambulatory male patients, aged 21 to 27 yrs. Hypovolemia induced by withdrawal of 400 ml blood, blood infusion followed by repeated centrifugation, effects of consuming an isotonic drink (0.9% NaCl) to achieve oral rehydration, and donning of red adaptation goggles were studied for effects on acceleration tolerance, pre-acceleration and post-acceleration plasma renin activity (PRA) and plasma vasopressin levels. No significant changes in post-acceleration PRA compared to pre-acceleration PRA were found, and administration of oral rehydration is found as effective as blood replacement in counteracting hypovolemic effects.

Greenleaf, J. E.↗

Visual response time to colored stimuli in peripheral retina - Evidence for binocular summation

Simple onset response time (RT) experiments, previously shown to exhibit binocular summation effects for white stimuli along the horizontal meridian, were performed for red and green stimuli along 5 oblique meridians. Binocular RT was significantly shorter than monocular RT for a 45-min-diameter spot of red, green, or white light within eccentricities of about 50 deg from the fovea. Relatively large meridian differences were noted that appear to be due to the degree to which the images fall on corresponding retinal areas.

Haines, R. F.↗

Optical instrument employing reticle having preselected visual response pattern formed thereon

An optical instrument for use in locating indicator lights or the like on a work surface is described. It comprises a tubular housing, a lens mounted within the housing and including an inner surface coated with a dichroic material that is capable of reflecting a portion of the light incident thereon, a plate mounted within the housing opposite the lens and having a central aperture, a transparent substrate disposed within the housing intermediate the lens and the plate, the substrate including a first surface disposed in a facing relationship to the dichroic material, and a reticle formed on the first surface and comprised of a material capable of reflecting light.

Haines, R. F.↗

Visual projection reticle

Small lightweight device visually superimposes visual-sensitivity and response contours on displays and instrument panels. Optical system provides 45 deg arc/diameter field of view; however, special wide-angle optics can be substituted without significant size or weight penalty.

Haines, R. F.↗

Heat Acclimation and Water-Immersion Deconditioning: Responses to Exercise

Simulated subgravity conditions, such as bed rest and water immersion, cause a decrease in a acceleration tolerance (3, 4), tilt tolerance (3, 9, 10), work capacity (5, 7), and plasma volume (1, 8-10). Moderate exercise training performed during bed rest (4) and prior to water immersion (5) provides some protection against the adverse effects of deconditioning, but the relationship between exercise and changes due to deconditioning remains unclear. Heat acclimation increases plasma and interstitial volumes, total body water, stroke volume (11), and tilt tolerance (6) and may, therefore, be a more efficient method of ameliorating deconditioning than physical training alone. The present study was undertaken to determine the effects of heat acclimation and moderate physical training, performed in cool conditions, on water-immersion deconditioning.

Shvartz, E.↗

Heat Acclimation and Water-Immersion Deconditioning: Fluid Electrolyte Shifts with Tilting

One of the major problems encountered by astronauts exposed to space flight is a reduction of orthostatic tolerance on return to earth. Many studies have been performed in an attempt to define the physiologic mechanism of orthostatic intolerance and to develop some remedial treatment. Exercise training does not appear to enhance orthostatic tolerance . In contrast, heat acclimation (i.e., exercise training in the heat) has been reported to enhance orthostatic tolerance. Since plasma volume increases with both exercise training and heat acclimation, it is not clear what role fluid and electrolytes play in determining tolerance to hydrostatic pressure. The purpose of this study was to compare the effects of exercise training in a cool environment and heat acclimation on resting plasma volume (PV) and the ensuing fluid and electrolyte shifts which occur during head-up tilting before and after water immersion deconditioning.

Conertino, V. A.↗

Effect of hypovolemia, infusion, and oral rehydration on gradual onset +Gz acceleration tolerance

The purpose of this study was to determine the effect of blood withdrawal, blood infusion, and oral fluid intake on +Gz tolerance at an acceleration rate of 0.5 G/min. Six healthy men aged 21-27 yr were centrifuged after the withdrawal of 400 ml of blood (hypovolemia) from each man; they were centrifuged again following blood infusion (Phase I). Three weeks later the men were accelerated after similar hypovolemia and again after consuming 800 ml of an isotonic NaCl drink (Phase II). Phase I hypovolemia resulted in a reduction in tolerance in all subjects from a mean control level of 6.42 + or - 0.35 min to 5.45 + or - 0.17 min (-15.1%, p less than 0.05). Both infusion and drinking returned tolerances to control levels. During acceleration there were significant (p less than 0.05) increases in plasma vasopressin levels to 35 pg/ml; these were not influenced appreciably by infusion or drinking. In all acceleration runs there was an obligatory shift (loss) of plasma volume and electrolytes, especially potassium, regardless of the experimental treatments. Oral rehydration is shown to be as effective as blood replacement in restoring +Gz acceleration tolerance decrements due to hypovolemia.

Greenleaf, J. E.↗

Visual examination apparatus

An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location including a projection system for displaying to a patient a series of visual stimuli. A response switch enables him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system thereby provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made.

Haines, R. F.↗

Binocular summation and peripheral visual response time

Six males were administered a peripheral visual response time test to the onset of brief small stimuli imaged in 10-deg arc separation intervals across the dark adapted horizontal retinal meridian under both binocular and monocular viewing conditions. This was done in an attempt to verify the existence of peripheral binocular summation using a response time measure. The results indicated that from 50-deg arc right to 50-deg arc left of the line of sight binocular summation is a reasonable explanation for the significantly faster binocular data. The stimulus position by viewing eye interaction was also significant. A discussion of these and other analyses is presented along with a review of related literature.

Gilliland, K.↗

Space station interior design: Results of the NASA/AIA space station interior national design competition

The results of the NASA/AIA space station interior national design competition held during 1971 are presented in order to make available to those who work in the architectural, engineering, and interior design fields the results of this design activity in which the interiors of several space shuttle size modules were designed for optimal habitability. Each design entry also includes a final configuration of all modules into a complete space station. A brief history of the competition is presented with the competition guidelines and constraints. The first place award entry is presented in detail, and specific features from other selected designs are discussed. This is followed by a discussion of how some of these design features might be applied to terrestrial as well as space situations.

Haines, R. F.↗

+Gz tolerance in man after 14-day bedrest periods with isometric and isotonic exercise conditioning

The effects of isometric and isotonic exercise training on post-bedrest +Gz tolerance were determined. In general, 14-day bedrest resulted in a significant loss of Gz tolerance, as previously discovered. At 2.1 Gz, neither the isometric nor the isotonic exercises regimens resulted in a significant increase in post-bedrest Gz tolerance. However, following isometric exercise, restoration of about half the tolerance decrement occurred at 3.2 Gz and 3.8 Gz. Possible reasons for this partial restoration of tolerance are put forward.

Greenleaf, J. E.↗

Response time to colored stimuli in the full visual field

Peripheral visual response time was measured in seven dark adapted subjects to the onset of small (45' arc diam), brief (50 msec), colored (blue, yellow, green, red) and white stimuli imaged at 72 locations within their binocular field of view. The blue, yellow, and green stimuli were matched for brightness at about 2.6 sub log 10 units above their absolute light threshold, and they appeared at an unexpected time and location. These data were obtained to provide response time and no-response data for use in various design disciplines involving instrument panel layout. The results indicated that the retina possesses relatively concentric regions within each of which mean response time can be expected to be of approximately the same duration. These regions are centered near the fovea and extend farther horizontally than vertically. Mean foveal response time was fastest for yellow and slowest for blue. Three and one-half percent of the total 56,410 trials presented resulted in no-responses. Regardless of stimulus color, the lowest percentage of no-responses occurred within 30 deg arc from the fovea and the highest within 40 deg to 80 deg arc below the fovea.

Haines, R. F.↗

Peripheral visual response time and retinal luminance-area relations

Experiments were undertaken to elucidate the stimulus luminance-retinal area relationship that underlies response time (RT) behavior. Mean RT was significantly faster to stimuli imaged beyond about 70 deg of arc from the fovea when their luminance was increased by an amount equal to the foveal stimulus luminance multiplied by the cosine of the angle between the peripheral stimuli and the line of sight. This and additional data are discussed in relation to previous psychophysical data and to possible response mechanisms.

Haines, R. F.↗

Peripheral visual response time to colored stimuli imaged on the horizontal meridian

Two male observers were administered a binocular visual response time task to small (45 min arc), flashed, photopic stimuli at four dominant wavelengths (632 nm red; 583 nm yellow; 526 nm green; 464 nm blue) imaged across the horizontal retinal meridian. The stimuli were imaged at 10 deg arc intervals from 80 deg left to 90 deg right of fixation. Testing followed either prior light adaptation or prior dark adaptation. Results indicated that mean response time (RT) varies with stimulus color. RT is faster to yellow than to blue and green and slowest to red. In general, mean RT was found to increase from fovea to periphery for all four colors, with the curve for red stimuli exhibiting the most rapid positive acceleration with increasing angular eccentricity from the fovea. The shape of the RT distribution across the retina was also found to depend upon the state of light or dark adaptation. The findings are related to previous RT research and are discussed in terms of optimizing the color and position of colored displays on instrument panels.

Haines, R. F.↗