Engineering Papers⌕ Search

Engineering topics

Hagopian, John G.

Publications and source records attributed to Hagopian, John G..

28 records · Page 2

Alignment and Polarization Sensitivity Study for the Cassini-Composite InfraRed Spectrometer (CIRS) Far InfraRed (FIR) Interferometer

The Composite InfraRed Spectrometer (CIRS) instrument flying on the Cassini spacecraft to Saturn is a cryogenic spectrometer with far-infrared (FIR) and mid-infrared (MIR) channels. The CIRS FIR channel is a polarizing interferometer that contains three polarizing grid components. These components are an input polarizer, a polarizing beamsplitter, and an output polarizer/analyzer. They consist of a 1.5 micron thick mylar substrate with 2 gm wide copper wires, with 2 gm spacing (4 micron pitch) photolithographically deposited on the substrate. This paper details the polarization sensitivity studies performed on the output polarizer/analyzer, and the alignment sensitivity studies performed on the input polarizer and beamsplitter components in the FIR interferometer.

Crooke, Julie A.↗

Effects of Shear, Defocus, and Wavefront Error on the Theoretical Performance of the Composite Infrared Spectrometer for Cassini

The combined effects on performance of shear between the two arms, defocus of die detector, and difference in wavefront between the two arms of a Fourier transform spectrometer using cube corner retroreflectors were investigated. Performance was characterized by the amplitude of the fringe signals coming from a detector as the path-length difference was scanned. A closed-form expression was found for the combined effects of shear and defocus, and it was found that defocus had no effect in the absence of shear. The effect of wavefront error was modeled numerically and assumed to be independent of shear and defocus. Results were compared with measurements made on the breadboard and engineering model of the Composite Infrared Spectrometer for the Cassini mission to Saturn, and good agreement was found.

Martino, Antonio J.↗

Throughput of the Composite Infrared Spectrometer (CIRS) Mid Infrared (MIR) Channel for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The instrument was aligned at ambient temperature, but operates at 170 Kelvin and has challenging interferometric alignment tolerances. Cryogenic alignment tests of the instrument indicate that it should suffer minimal degradation due to the cooldown from ambient to operational temperature. System level tests performed by the calibration team indicated a lower than expected signal level on the MIR channel, while providing ambiguous optical throughput data. Therefore it became imperative to develop a metric that could be used to determine the instrument performance at both the instrument and system levels, at ambient and cryogenic temperature. Modulation efficiency and throughput measurements were performed and new analytical models developed to evaluate the status of the instrument. Empirical and analytical data were eventually reconciled and deviations from the design values explained.

Hagopian, John G.↗

Acoustic Amplification in the Far Infrared Focal Plane Assembly of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared FIR and mid infrared, MIR wavelength region. The FIR is a polarizing Michelson interferometer which presents a collimated output beam to the FIR focal plane. The focal plane consists of a parabolic focus mirror and an analyzer grid, which splits the output beams into transmitted and reflected components. The two polarizations are focussed onto two thermopile detectors; each consisting of a gold black foil welded to the top of two bismuth pyramids. The gold black is 30 microns thick, and the weld area is approximately 2 microns in diameter. The detectors are extremely fragile and the weld can be broken with a miniscule amount of airflow. The detectors consistently passed acoustic testing to qualification levels that simulated the launch environment of the Titan IV launch vehicle. However, they experienced a 50% failure rate when installed in the focal plane assembly during instrument level acoustic tests. A test focal plane was developed with small pressure transducers in the nominal detector locations. These tests indicated over 10 dB of acoustic amplification in the focal plane within the instrument during testing. New techniques were developed to allow testing of the focal plane without over testing the instrument, and modifications were made the focal plane assembly to successfully attenuate the amplification.

Hagopian, John G.↗

Shear/Defocus Sensitivity of the Mid Infrared Channel (MIR) of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The mid infrared wavelength interferometer has a focal plane consisting of a germanium focus lens and HgCdTe array. System level calibration of the CIRS Flight Unit indicated a discrepancy between the expected and actual signal levels. Testing on the CIRS breadboard and Engineering Unit indicated that defocus of the germanium lens could significantly reduce the modulation efficiency of the interferometer in the presence of a moderate degree of wavefront shear. Defocus of the lens in the focal plane was of concern because of the temperature dependence of the index of refraction of germanium and our nominal operation temperature of 170 K. The shear/defocus interaction was extensively investigated and correlated to a newly developed analytical model, It was eventually determined that the CIRS instrument was in focus, had no appreciable wavefront shear and was operating near theoretical limits. The shear/defocus effect is however, of considerable interest, since it has not been described in previous literature on interferometers.

Martino, Anthony J.↗

Characterization Of Electrical Response Of Photodetector

Fourier analysis is basis of method of characterizing electrical frequency or time response of photodetector. In method, detector stimulated by optical input signal, intensity modulated with square wave or other repetitive waveform of known frequency spectrum, and output of detector recorded. Electro-optical transfer function, which characterizes frequency response of detector, then computed as ratio between discrete Fourier transforms of output and input waveforms.

Hagopian, John G.↗

Monitoring Small Deformations In An Instrument

Relatively simple source/detector pairs measure changes affecting optical alignment. System for monitoring small thermal, gravitational, and dynamical deformations in x-ray telescope includes two sources of infrared light, each associated with dual-axis, position-sensing photodiode. Principle of operation straightforward and applicable to monitoring of small lateral translations and/or rotations between different parts in machinery, buildings, bridges, ships, and other large structures.

Hagopian, John G.↗

Calibration of optical detectors using discrete Fourier transform techniques

A method for determining the detector electrooptical transfer function (DEOTF) at different discrete frequencies simultaneously is presented. It involves simulation of the detector with a waveform of unknown frequency composition, such as a square wave or impulse function. The DEOTF is calculated as the ratio of the discrete Fourier transform of the detector output to the transform of the input waveform. This technique was successfully applied to Golay cell and bolometer detectors and can be used for other linear detector systems.

Hagopian, John G.↗

FIRAS optical alignment and performance during vibration qualification and cryogenic cycling

NASA's Cosmic Background Explorer (COBE) is designed to investigate the Cosmic Background Radiation (CBR), that permeates the universe as a consequence of the Big Bang. This 3 degree Kelvin radiation is a fossil that contains much information about the early universe. The Far Infrared Absolute Spectrophotometer (FIRAS), will investigate the spectral isotropy of this ancient remnant and look for clues as to the subsequent evolution of the universe. The instrument is a cryogenically cooled, modified Michelson interferometer which operates in the 1 cm to 100 micron wavelength range. FIRAS is designed to provide absolute spectral information, therefore, all possible perturbations to the instrument response must be investigated to minimize distortions of the data. This paper discusses the methodology and resultant variations in the instrument performance noted during room temperature, and liquid nitrogen, (LN2) temperature vibration qualification. Reference alignment shifts in critical components such as the instrument wire-grid beamsplitter are correlated to changes in the instrument spectral response.

Hagopian, John G.↗

Broad band X-ray telescope (BBXRT) displacement monitor system (DMS) testing and calibration

NASA's shuttle-borne Broad Band X-Ray Telescope (BBXRT) consists of two glancing incidence imaging mirror assemblies mounted on an optical bench which is bolted to the primary structure of the instrument. The X-ray detectors are located in the focal plane of the mirror assemblies approximately 3.5 meters away. It is desirable to monitor the relative alignment of these components throughout ground testing, and to determine the magnitude of launch or thermally induced perturbations to the alignment during flight. The Displacement Monitor System (DMS) was designed to accomplish this task. This paper describes the design of the DMS, the development and optimization of the DMS calibration facility, and the characterization of the system. The characterization of the DMS includes environmental qualification, displacement vs output calibration over the operating temperature range, a detailed error analysis, and the generation of a calibration polynomial which utilizes DMS detector output and thermocouple data to optimize system performance. The DMS accuracy exceeded the requirements of a 15 arc second limit of error, and passed the stringent environmental tests. As such, the DMS is one of the first flight qualified displacement monitor systems with this accuracy to be flown in space.

Hagopian, John G.↗