Engineering Papers⌕ Search

Engineering topics

Hagmann, C.

Publications and source records attributed to Hagmann, C..

At least 19 records

Development of a rapid-transit system for precision nuclear physics measurements

A Rapid Belt-driven Irradiated Target Transfer System, named RABITTS, was developed for use at the Triangle Universities Nuclear Laboratory. This system allows for cyclic activation with neutron or photon beams, and measurement of reaction products using γ-ray spectroscopy. Both a 1 meter and 10 meter transfer system have been developed with transit times as low as 0.4 and 1.0 seconds, respectively. The systems are deployed at the tandem accelerator laboratory for use with monoenergetic neutron beams, and at the High-Intensity γ-ray Source facility for activation using photon beams. A detailed characterization of the systems’ performance and sensitivity is presented. In order to produce the highest accuracy cross-section data, a model for calculating corrections to cyclic activation with variable beam flux is developed and presented. We have commissioned these systems by measuring 197m Au, where we report a measured half-life of 7.73 ± 0.05 s and a 197 Au(n, n') 197m Au isomer production cross of 628 ± 28 mb at neutron energy E n = 2.0 MeV. In addition, we measured 90m Zr, where we report a measured half-life of 799.7 ± 8.0 ms and a 90 Zr(n, n') 90m Zr isomer production cross of 180 ± 12 mb at E n = 4.6 MeV. Furthermore, these measured half-lives are in excellent agreement with the evaluated values and the cross-section measurements are performed at previously unmeasured incident neutron energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

In this work, the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-induced fission fragment angular distributions, anisotropy, and linear momentum transfer measured with the NIFFTE fission time projection chamber

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning 235 U, 238 U, and 239Pu and fission fragment angular anisotropy of 235 U and 238 U as a function of neutron energies in the range 130 keV–250 MeV are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission fragment angular anisotropy in neutron-induced fission of U 235 measured with a time projection chamber

Fission fragment angular distributions can provide an important constraint on fission theory, improving predictive fission codes, and are a prerequisite for a precise ratio cross section measurement. Available anisotropy data are sparse, especially at neutron energies above 5 MeV. For the first time, a three-dimensional tracking detector is employed to study fragment emission angles and provide a direct measurement of angular anisotropy. The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has deployed the fission time projection chamber to measure nuclear data with unprecedented precision. The fission fragment anisotropy of 235 U has been measured over a wide range of incident neutron energies from 180 keV to 200 MeV; a careful study of the systematic uncertainties complement the data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of the normalized U 238 ( n , f ) / U 235 ( n , f ) cross section ratio from threshold to 30 MeV with the NIFFTE fission Time Projection Chamber

We present that the normalized 238 U(n,f)/ 235 U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber (fissionTPC) from the reaction threshold to 30 MeV . The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time of-flight. The 238 U(n,f)/ 235 U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the 238 U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.β5 at 14.5 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of a MICROMEGAS-based TPC in a high-energy neutron beam

The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). We report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. And for a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.

43 PARTICLE ACCELERATORS↗

Modeling ionization and recombination from low energy nuclear recoils in liquid argon

Coherent neutrino-nucleus scattering (CNNS) is an as-yet undetected, flavor-independent neutrino interaction predicted by the Standard Model. CNNS is a flavor-blind interaction, which offers potential benefits for its use in nonproliferation (nuclear reactor monitoring) and astrophysics (supernova and solar neutrinos) applications. One challenge with detecting CNNS is the low energy deposition associated with a typical CNNS nuclear recoil. In addition, nuclear recoils are predicted to result in lower ionization yields than those produced by electron recoils of the same energy. This ratio of nuclear- and electron-induced ionization, known as the nuclear quenching factor, is unknown at energies typical for CNNS interactions in liquid xenon (LXe) and liquid argon (LAr), detector media being considered for CNNS detection. While there have been recent measurements [1] of the ionization yield from nuclear recoils in LAr, there is no universal model for nuclear quenching and ionization yield. For this reason, a Monte Carlo simulation has been developed to predict the ionization yield at sub-10 keV energies. The local ionization yield of a recoiling atom in the medium is calculated first. The ejected electrons are subsequently tracked in the electric field resulting from both the local electric charges and the externally applied drift field. The dependence of the ionization yield on the drift electric field is obtained by combining the calculated ionization yield for the initial collision cascade with the electron escape probability. An updated estimate of the CNNS signal expected in a LAr detector operated near a nuclear power reactor is presented.

CNNS↗

Note: Radiochemical measurement of fuel and ablator areal densities in cryogenic implosions at the National Ignition Facility

A new radiochemical method for determining deuterium-tritium (DT) fuel and plastic ablator (CH) areal densities (ρR) in high-convergence, cryogenic inertial confinement fusion implosions at the National Ignition Facility is described. It is based on measuring the {sup 198}Au/{sup 196}Au activation ratio using the collected post-shot debris of the Au hohlraum. The Au ratio combined with the independently measured neutron down scatter ratio uniquely determines the areal densities ρR(DT) and ρR(CH) during burn in the context of a simple 1-dimensional capsule model. The results show larger than expected ρR(CH) values, hinting at the presence of cold fuel-ablator mix.

07 ISOTOPE AND RADIATION SOURCES↗

First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of 37 Ar, respectively. The 37 Ar source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed 55 Fe x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Review of Particle Physics

D0–D0 MIXING Revised March 2012 by D. Asner (Pacific Northwest National Laboratory)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation hardening of gated x-ray imagers for the National Ignition Facility (invited)

The National Ignition Facility will soon be producing x-ray flux and neutron yields higher than any produced in laser driven implosion experiments in the past. Even a non-igniting capsule will require x-ray imaging of near burning plasmas at 10{sup 17} neutrons, requiring x-ray recording systems to work in more hostile conditions than we have encountered in past laser facilities. We will present modeling, experimental data and design concepts for x-ray imaging with electronic recording systems for this environment (ARIANE). A novel instrument, active readout in a nuclear environment, is described which uses the time-of-flight difference between the gated x-ray signal and the neutron which induces a background signal to increase the yield at which gated cameras can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2009 Release of the Evaluated Nuclear Data Library (ENDL2009)

LLNL's Computational Nuclear Physics Group and Nuclear Theory and Modeling Group have collaborated to produce the next iteration of LLNL's evaluated nuclear database ENDL2009. ENDL2009 is the second in a series of major ENDL library releases designed to support LLNL's current and future nuclear data needs. This library contains many new evaluations for radiochemical diagnostics, structural materials, and thermonuclear reactions. We have striven to keep ENDL2009 at the leading edge of nuclear data library development by reviewing and incorporating new evaluations as they are made available to the nuclear data community. In addition, ENDL2009 support new features such as energy dependent Q values from fission and unresolved resonances. Furthermore, this is the first ENDL library release to be released in the TDF format. Finally, this release is our most highly tested release as we have strengthened our already rigorous testing regime by adding tests against LANL Activation Ratio Measurements and many more new critical assemblies. Our testing is now being incorporated into our development process and is serving to guide library improvements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A two-stage magnetic refrigerator for astronomical applications with reservoir temperatures above 4 K

We propose a novel adiabatic demagnetization refrigerator (ADR) to produce temperatures as low as 100 mK starting from a high temperature reservoir between 4 and 8 K. The high temperature reservoir for the ADR can be provided by a mechanical cooler or an unpumped liquid helium bath. This refrigerator can be used to cool bolometric infrared detectors for low background astronomy from mountain tops, balloons or satellites as well as to cool cryogenic x-ray detectors. The two-stage ADR consists of a single magnet with a paramagnetic chromic-cesium-alum (CCA) salt pill to produce the low temperature and paramagnetic gadolinium-gallium-garnet (GGG) as the first stage to intercept heat from the high temperature reservoir. Thermal contact between the paramagnets and the reservoir during magnetization is made with a mechanical heat switch. The ADR is suspended with Kevlar chords under tension for high mechanical stiffness and low parasitic heat leak. In a single cycle, the ADR maintains a temperature of 100 mK for 10 to 100 hours. This time depends strongly on the magnetic field and reservoir temperature but not on the volume of the paramagnetic material as long as the heat leak is dominated by the suspension.

Hagmann, C.↗