Engineering Papers⌕ Search

Engineering topics

HSU, P C

Publications and source records attributed to HSU, P C.

SMALL-SCALE SAFETY TEST REPORT FOR RDX (SECOND CALIBRATION)

RDX was provided by Indian Head and was dried at 60 C for 16 hours, cooled and kept in a desiccator before use. Please note that the impact testing was done on both pellets and loose powder which resulted in different data. The impact sensitivity on pressed pellets was 34 cm that is greater than that on loose powder, as expected. The impact test data on the loose powder was similar to what Indian Head and LANL got. Remarkable consistent results were observed for test results of loose powder RDX. The average impact sensitivyt (DH{sub 50}) was 21.8 cm and the average friction sensitivity (F{sub 50}) for loose powder was 24.9 kg, respectively. DSC charts showed that peak temperatures and onset temperatures for all 3 runs of RDX samples were almost identical. All electrostatic spark sensitivity was 0/10 at 1.0 J with a 510-ohm resistor in the discharge circuit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A BRIEF DESCRIPTION OF THE SMALL-SCALE SAFETY TESTING SYSTEMS AT LAWRENCE LIVERMORE NATIONAL LABORATORY

Small-scale sensitivity testing is important for determining material response to various stimuli including impact, friction, and static spark. These tests, briefly described below, provide parameters for safety in handling. ERL Type 12 drop hammer equipment at LLNL, shown in Figure 1, was used to determine the impact sensitivity. The equipment includes a 2.5-kg drop weight, a striker (upper anvil, 2.5 kg for solid samples and 1.0 kg for liquid samples), a bottom anvil, a microphone sensor, and a peakmeter. For each drop, sample (35 mg for solid or 45 microliter for liquid) is placed on the bottom anvil surface and impacted by the drop weight from different heights. Signs of reactions upon impact are observed and recorded. These signs include noises, flashes or sparks, smoke, pressure, gas emissions, temperature rise due to exothermic reaction, color change of the sample, and changes to the anvil surface (noted by inspection). For solid samples, a 'GO' was defined as a microphone sensor (for noise detection) response of {ge} 1.3 V as measured by a peakmeter. The higher the DH{sub 50} values, the lower the impact sensitivity. The method used to calculate DH{sub 50} values is the 'up and down' or Bruceton method. PETN and RDX have impact sensitivities of 15 and 35 cm, respectively. TATB has impact sensitivity more than 177 cm. For liquid samples, a 'GO' was determined by the noise levels as measured by the peakmeter, appearance of flashes, temperature rise of the anvil, and visual inspection of the anvil surface. Two liquid samples TMETN and FEFO have impact sensitivities of 14 and 32 cm, respectively. Figure 2 shows a 'GO' event observed during the impact sensitivity test; flashes appeared as the drop weight impacted the sample. A BAM friction sensitivity test machine, as shown in Figure 3, was used to determine the frictional sensitivity. The system uses a fixed porcelain pin and a movable porcelain plate that executes a reciprocating motion. Weight affixed to a torsion arm allows for a variation in applied force between 0.5 kg to 36.0 kg. The relative measure of the frictional sensitivity of a material is based upon the smallest load (kg) at which reaction occurs for a 1-in-10 series of attempts. The lower the load values, the higher the frictional sensitivity. PETN has a frictional sensitivity of 6.4 kg. The static spark machine at LLNL is used to evaluate the electrostatic discharge hazards (human ESD) associated with the handling of explosives. The machine was custom-built almost 30 years ago and consists of a capacitor bank (up to 20,000 pF), a voltage meter, and a discharge circuit, as shown in Figure 4. An adjustable resistor up to 510 ohms (chosen to simulate human body) is wired to the discharge circuit. A 5-mg sample is placed in a Teflon washer sealed to a steel disc and covered with a Mylar tape. High static voltage (up to 10 kv) is applied and discharged to the sample. Evidence of reaction is judged from the condition of Mylar tape, smokes, and color change of the sample. Voltage, capacitance, and resistance can be adjusted to achieve the desired static energy. The results obtained are expressed as a zero in 10 or one-in-ten at a specific voltage and joules. One reaction in ten trials at {le} 0.25 joules is considered spark-sensitive. Primary explosives show reaction at 0.1 joule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SMALL-SCALE IMPACT SENSITIVITY TESTING ON EDC37

EDC37 was tested at LLNL to determine its impact sensitivity in the LLNL's drop hammer system. The results showed that impact sensitivities of the samples were between 86 cm and 156 cm, depending on test methods. EDC37 is a plastic bonded explosive consisting of 90% HMX, 1% nitrocellulose and binder. We recently conducted impact sensitivity testing in our drop hammer system and the results are presented in this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗